*2019/01/17 16:56:00.85 *IOS HEADER VERSION 2.0 2016/04/28 2016/06/13 IVF16 *FILE START TIME : UTC 1998/05/14 06:25:00.000 NUMBER OF RECORDS : 22 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 9 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------------------------- --------- -------------- -------------- 1 Pressure decibar 1.21 503.11 2 Temperature 'deg C' -1.7633 -0.3794 3 Bottle_Number n/a 1 22 4 Salinity PSS-78 32.8816 34.2417 5 Number_of_bin_records n/a 56 100 6 Carbon:Total:Organic umol/kg 73 128 7 Carbon:Particulate:Total umol/kg 3.051 8.942 8 Flag:Carbon:Particulate:Total n/a 9 Nitrogen:Particulate:Total umol/kg 0.3 1.32 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ------ -------------- 1 ' ' ' ' 11 F ' ' 2 2 ' ' ' ' 9 F ' ' 4 3 ' ' ' ' 4 F ' ' 0 4 ' ' ' ' 9 F REAL*4 4 5 ' ' ' ' 5 F ' ' 0 6 -99 ' ' ' ' F6.0 R4 ' ' 7 -99 ' ' ' ' F8.3 R4 ' ' 8 0 ' ' 3 NQ C ' ' 9 -99 ' ' ' ' F7.2 R4 ' ' $END $REMARKS Flag channels initialized with zeros. Non-zero values have the following significance: -------------------------------------------------------------------------------------- 1 = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). 2 = Acceptable measurement (not normally used). 3 = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). 4 = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). 5 = Not reported (lost sample; unredeemably bad measurement). 6 = Mean of replicate measurements. 7 = Manual chromatographic peak measurement. 8 = Irregular digital chromatographic peak integration. 9 = Sample not drawn for this measurement from this bottle (not normally used). -------------------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 1998-12 AGENCY : GIROQ/IOS COUNTRY : Canada PROJECT : Northwater Polynya SCIENTIST : Fortier L. PLATFORM : CCGS Pierre Radisson *LOCATION STATION : 175 EVENT NUMBER : 175 LATITUDE : 77 48.31000 N ! (deg min) LONGITUDE : 75 37.11700 W ! (deg min) WATER DEPTH : 522 *INSTRUMENT TYPE : FSI CTD MODEL : ICTD SERIAL NUMBER : 1329 $TABLE: SENSORS ! Name Abs Depth Serial No ! ---------------- -------------- ---------- Pressure n/a 1329 Temperature n/a 1329 Conductivity n/a 1329 Thermistor1 n/a 1329 'Touch Down' n/a 0 Transmissivity n/a 598 Chlorophyl n/a 93S $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------ ------ ---------- -------- --------- --------- FSICNVT 1.3 1998/11/23 16:06:20 10006 10006 CALIB 10.2 2002/04/04 16:00:11 1897 1897 CALIB 10.2 2002/04/08 09:23:07 1897 1897 BINAVE 4.0.1 2002/04/08 09:26:18 1897 22 HDREDIT2 1.3 2002/04/09 14:03:45 ? ? REMOVECH 8.2 2013/12/24 11:41:14 22 22 SORT 3.6 2013/12/24 11:42:44 22 22 MERGE 3.5 2013/12/24 12:52:25 22 22 HDREDIT2 2.6 2013/12/24 13:04:59 ? ? HDREDIT2 2.6 2013/12/24 13:06:07 ? ? CLEAN 5.1 2013/12/24 13:10:04 22 22 HDREDIT2 2.6 2013/12/24 14:29:06 ? ? CHANGE_MISSION_IDs 1.0 2014/03/03 10:29:20 22 22 CHANGE_FLAGS 2.0 2014/11/20 09:52:11 22 22 HDREDIT2 3.1.1 2019/01/17 16:56:00 ? ? $END $REMARKS -The following FSICNVT parameters were used: Project Name: Northwater Polynya Config File: W:\ctd\9812\1329.txt FSI Configuration File Summary: Number of Channels: 7 Bytes/Record: 19 Records/Second : 25 CTD Serial #: 1329 Channel Raw Units Cal Units Serial # Format Scale Pos -------------------- ---------- ---------- ---------- -------- ---------- --- Pressure Dbars Dbars 1329 F10.1 .1000 2 Temperature Deg C Deg C 1329 F12.4 .0005 4 Conductivity mmho/cm Ratio 1329 F12.6 .0010 6 Thermistor1 Deg C Deg C 1329 F12.4 .0005 9 Touch Down raw raw 0 F8.0 1.0000 11 Transmissivity raw % 598 F10.2 1.0000 13 Chlorophyl raw mg/m^3 93S F10.2 1.0000 15 -The following CALIB parameters were used: Calibration type = Raw Mode: UNION - calibration specs from Header and Cal File. Salinity is computed Calibration file = M:\Data\9812\9812RCAL.txt Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 1 Pressure Dbars 10 -0.6000000E+00 0.1000000E+01 2 Temperature Deg C 10 0.2452940E-01 0.9962400E+00 0.1587200E-03 -0.1968500E-05 3 Conductivity Ratio 68 0.0000000E+00 0.1000000E+01 Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 9 Salinity PSS-78 130 Pressure Temperature Conductivity -The following CALIB parameters were used: Calibration type = Correct Mode: ONLY - calibration specs from Cal File only. Salinity is computed Calibration file = M:\Data\9812\9812_cond_cal.CCF Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 3 Conductivity Ratio 10 0.0000000E+00 0.9990838E+00 Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 9 Salinity PSS-78 130 Pressure Temperature Conductivity -The following BINAVE parameters were used: Bin channel = Bottle Number Averaging interval = 1.0 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -REMOVECH 2013/12/24 11:41:14 The following CHANNEL(S) were removed: Conductivity [Ratio] Thermistor1 [Deg C] Touch Down [raw] Transmissivity [%] Chlorophyl [mg/m^3] -SORT parameters: 2013/12/24 11:42:44 Sorted in ascending order of channel Pressure -The following MERGE parameters were used: 2013/12/24 12:52:25 Merge Channel: Pressure Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Average Primary Channels to Include: ALL Secondary Channels to Include: Carbon:Dissolved:Inorganic, Flag:Carbon:Dissolved:Inorganic, Alkalinity:Total, Flag:Alkalinity:Total, Carbon:Total:Organic, Carbon:Particulate:Total, Flag:Carbon:Particulate:Total, Nitrogen:Particulate:Total, Oxygen:Dissolved, Flag:Oxygen:Dissolved Primary file : P:\Cruise_Data_Processing\Lisa Miller's Carbon Data\1998-12\1998-12-0175.remsrt Secondary file: P:\Cruise_Data_Processing\Lisa Miller's Carbon Data\1998-12\1998-12-0175.ios -HEADER EDITS: 2013/12/24 13:04:59 Applied edit header: O:\Data Processing\Header Comments\Work\Quality_Flags_numeric.txt Channel 1: Pressure [decibar] Units: Dbars ==> decibar Channel 2: Temperature [deg C] Units: Deg C ==> deg C Channel 3: Bottle_Number [n/a] Name: Bottle Number ==> Bottle_Number -HEADER EDITS: 2013/12/24 13:06:07 - none. -CLEAN functions: 2013/12/24 13:09:59 20 Reset #RECS, MIN & MAX values in header. Delete Empty Channels: 6 deleted. -HEADER EDITS: 2013/12/24 14:29:06 Applied edit header: P:\Cruise_Data_Processing\Lisa Miller's Carbon Data\DIC_ALK.txt -HEADER EDITS: 2019/01/17 16:56:00 Applied edit header: P:\Cruise_Data_Processing\2018-040\Processing\ios\1998-12-hdr.txt $END *RAW START TIME : UTC 1998/05/14 06:25:00.000 TIME INCREMENT : 0 0 0 0 40 ! (day hr min sec ms) NUMBER OF RECORDS : 10006 $TABLE: CHANNELS ! Averaging (day hr min sec ms) !Name Raw Units Interval Time Lag !---------------- --------- --------- ----------- Pressure Dbars Temperature 'Deg C' Conductivity mmho/cm Thermistor1 'Deg C' 'Touch Down' raw Transmissivity raw Chlorophyl raw $END *CALIBRATION START TIME : UTC 1998/05/14 06:25:00.000 $TABLE: RAW CHANNELS ! Name Units Fmla Pad Coefficients ! -------------- ------- ---- ------ ------------ Pressure Dbars 10 ' ' (-0.6 1) Temperature 'Deg C' 10 ' ' (0.245294E-01 0.99624 0.15872E-03 -0.19685E-05) Conductivity Ratio 68 ' ' (0 1) $END $TABLE: CALCULATED CHANNELS ! Name Units Fmla Pad Coefficients ! ---------- -------- ---- ------ ------------ Salinity PSS-78 130 ' ' (Pressure Temperature Conductivity) () Salinity PSS-78 130 ' ' (Pressure Temperature Conductivity) () $END $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! -------------- ------- ---- ------ ------------ Conductivity Ratio 10 ' ' () (0 0.9990838) $END *COMMENTS Dissolved inorganic carbon (DIC) was determined using coulometric analysis. Total alkalinity (Alk) was determined by potentiometric titration. Complete documentation on DIC and ALK sampling, analysis and precision estimates can be found in the Carbon Excel file from the cruise located in the cruise "DOC" directory. . !----1----- ---2---- -3- ---4---- -5-- --6-- ---7--- 8- --9--- ! Pressure Temperat Bot Salinity Numb Carbo Carbon: Fl Nitrog ! ure tle er_o n: Particu ag en: ! _ ~bin Total late: ~T Partic ! Num _rec :Orga Total ot ulate: ! ber ords nic al Total !---------- -------- --- -------- ---- ----- ------- -- ------ *END OF HEADER 1.21 -1.7591 22. 32.8819 100. 98. 8.942 0 1.29 9.38 -1.7633 21. 32.8816 100. 94. 6.297 0 1.32 19.57 -1.7601 19. 32.8868 100. -99. -99.000 0 -99.00 19.73 -1.7605 20. 32.8851 74. 100. 8.000 0 0.89 26.99 -1.7516 17. 32.9191 100. -99. -99.000 0 -99.00 27.02 -1.7547 18. 32.9040 65. 128. 7.145 0 0.98 39.15 -1.7374 16. 33.0051 100. -99. -99.000 0 -99.00 56.94 -1.7498 14. 33.0287 100. -99. -99.000 0 -99.00 57.09 -1.7512 15. 33.0313 70. 114. 3.101 0 0.72 84.28 -1.7205 12. 33.1038 100. -99. -99.000 0 -99.00 84.59 -1.7200 13. 33.1027 61. 113. 3.051 0 0.65 100.22 -1.6394 10. 33.1325 100. -99. -99.000 0 -99.00 100.56 -1.6395 11. 33.1334 79. 107. -99.000 0 -99.00 200.80 -1.2002 8. 33.6019 100. -99. -99.000 0 -99.00 201.69 -1.1747 9. 33.5997 57. 93. 5.299 0 0.69 299.79 -0.6349 6. 33.9815 100. -99. -99.000 0 -99.00 300.37 -0.6341 7. 33.9816 56. 73. 7.456 0 0.60 399.47 -0.4630 4. 34.1595 100. -99. -99.000 0 -99.00 399.81 -0.4628 5. 34.1595 65. 77. 3.933 0 0.30 499.60 -0.3814 2. 34.2401 100. -99. -99.000 0 -99.00 499.84 -0.3819 3. 34.2396 70. -99. -99.000 0 -99.00 503.11 -0.3794 1. 34.2417 100. 116. -99.000 0 -99.00