*2013/12/16 15:14:46.67 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 1998/05/28 01:15:47.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 3 DATA DESCRIPTION : Bottle:Rosette:Up:Stop FILE TYPE : ASCII NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ----------------- --------- -------------- -------------- 1 Sample_Number n/a 22 24 2 Pressure decibar 503.4 2503.2 3 Salinity:Bottle PSS-78 34.0896 34.6343 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 9 F ' ' 4 $END *ADMINISTRATION MISSION : 1998-11 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Laperouse SCIENTIST : Juhasz T. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : WEST COAST VANCOUVER ISLAND STATION : ENP8 EVENT NUMBER : 2 LATITUDE : 48 48.94000 N ! (deg min) LONGITUDE : 128 39.90000 W ! (deg min) *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- CALIB 7.5 1999/04/21 09:57:18 3 3 REMOVECH 3.2 2000/01/11 15:16:42 3 3 HDREDIT2 1.8 2004/01/12 15:48:05 ? ? SORT 3.4.1 2004/01/12 15:48:50 3 3 CLEAN 4.5 2004/01/12 15:49:07 3 3 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:14:46 3 3 $END $REMARKS -The following CALIB parameters were used: Calibration type = C Pressure offset = 0.0 Calibration file = d:\data\1998\9811\9811oxy.cor -The following CHANNEL(S) were removed from file. Salinity:Primary SALINITY:SECONDARY TEMPERATURE:SECONDARY Temperature:Primary SALINITY:T0:C0 SALINITY:T1:C1 TEMPERATURE:SAMPLE DISSOLVED_OXYGEN:MASS THIOSULFATE_TITER FLASK_NUMBER FLASK_VOLUME BLANK STANDARD IRRADIANCE_PAR CHL_FLUORESCENCE Transmissivity BOTTLE_NUMBER SALINITY:CTD TEMPERATURE:CTD Temperature -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. - Remove Sea-Bird comments from the header. $END *CALIBRATION *INSTRUMENT TYPE : Bottle MODEL : Niskin 10 Litre *COMMENTS Collection method: ------------------ A rosette, holding 24 ten-litre water samplers, with a CTD was used. Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. References: 1. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. !-1-- --2--- ---3---- !Samp Pressu Salinity !le_ re :Bottle !Numb !er !---- ------ -------- *END OF HEADER 24 503.4 34.0896 23 1001.0 34.3753 22 2503.2 34.6343