*2013/12/16 15:14:35.44 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 1998/05/10 09:34:33.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 10 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII NUMBER OF CHANNELS : 4 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- -------------------------- --------- -------------- -------------- 1 Sample_Number n/a 91 100 2 Pressure decibar 200.3 1547.8 3 Fluorescence:URU:Wetlabs mg/m^3 6.505 9.614 4 Salinity:Bottle PSS-78 33.8948 34.5345 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 8 F ' ' 3 4 -99 ' ' 9 F ' ' 4 $END $REMARKS This file converted from Sea-Bird file: d:\data\9809\98090031.ros $END *ADMINISTRATION MISSION : 1998-09 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Laperouse, GLOBEC, CRD SCIENTIST : Juhasz T. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : STATION : LB15 EVENT NUMBER : 31 LATITUDE : 48 4.45000 N ! (deg min) LONGITUDE : 126 8.64000 W ! (deg min) *INSTRUMENT TYPE : Bottle MODEL : Niskin 10 Litre SERIAL NUMBER : 0443 $TABLE: SENSORS ! Name Abs Depth Serial No ! ------------------------ -------------- ---------- temperature:primary ' ' 2095 conductivity:primary ' ' 1763 pressure ' ' 63507 temperature:secondary ' ' 2142 conductivity:secondary ' ' 1766 userpoly ' ' FPK-018 transmissometer ' ' 182D $END $REMARKS SOFTWARE VERSION 4.229 $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SBE_IOS 1.1 1998/05/11 20:10:14 1210 1210 BINAVE2 1.0 1998/05/11 20:13:23 1210 10 MERGE 1.0 1998/05/11 14:19:00 10 10 MERGE 1.0 1998/05/11 14:29:17 10 10 CALIB 7.5 1999/04/21 10:02:34 10 10 REMOVECH 3.2 2000/01/11 12:23:37 10 10 HDREDIT2 1.8 2004/01/12 10:56:15 ? ? REVERSE 2.0 2004/01/12 10:57:41 10 10 CLEAN 4.5 2004/01/12 10:57:54 10 10 REMOVECH 6.0 2004/05/26 14:06:13 10 10 HDREDIT2 2.2 2004/09/22 13:51:54 ? ? CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:14:35 10 10 $END $REMARKS -The following BINAVE2 parameters were used: Bin channel = Sample_number Averaging interval = 1.0 Minimum bin value = .000 Bin value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following MERGE parameters were used: Primary File Extension: avg Secondary File Extension: oxy Merge Channel: Sample_Number Merge Scheme Used: Interweave Records from Both Files Overlap Scheme Used: Keep Primary Primary Channels to Include: Sample_Number,Pressure,Temperature:primary,Salinity:T0:C0,Salinity:T1:C1,Transm Secondary Channels to Include: Sample_Number,Dissolved_Oxygen:vol,Flask_Number -The following MERGE parameters were used: Primary File Extension: tab Secondary File Extension: ios Merge Channel: Sample_Number Merge Scheme Used: Interweave Records from Both Files Overlap Scheme Used: Keep Primary Primary Channels to Include: Sample_Number,Pressure,Temperature:primary,Salinity:T0:C0,Salinity:T1:C1,Transm Secondary Channels to Include: Sample_Number,Salinity:bottle -The following CALIB parameters were used: Calibration type = C Pressure offset = 0.0 Calibration file = d:\data\1998\9809\9809oxy.cor -The following CHANNEL(S) were removed from file. SALINITY:PRIMARY SALINITY:SECONDARY TEMPERATURE:SECONDARY Temperature:Primary Salinity:T0:C0 Salinity:T1:C1 TEMPERATURE:SAMPLE DISSOLVED_OXYGEN:MASS THIOSULFATE_TITER FLASK_NUMBER FLASK_VOLUME BLANK STANDARD Transmissivity SALINITY:CTD TEMPERATURE:CTD Temperature CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. - Remove Sea-Bird comments from the header. -The following CHANNEL(S) were removed from file. Sample_number -HEADER EDITS: Channel 3: Fluorescence:URU [mg/m^3] Name ==> Fluorescence:URU:Wetlabs $END *COMMENTS Collection method: ------------------ A rosette, holding 24 ten-litre water samplers, with a CTD was used. Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. References: 1. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. *CALIBRATION !-1-- --2--- ---3--- ---4---- !Samp Pressu Fluores Salinity !le_ re cence: :Bottle !Numb URU: !er Wetlabs !---- ------ ------- -------- *END OF HEADER 100 200.3 7.418 33.8948 99 252.4 7.542 33.9629 98 302.4 7.939 34.0066 97 399.8 8.089 34.0849 96 501.5 6.505 34.1531 95 599.2 9.614 34.2099 94 794.2 8.995 34.3132 93 1001.0 6.832 34.3982 92 1199.0 7.514 34.4570 91 1547.8 8.839 34.5345