*2014/02/03 17:02:42.70 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 1998/03/03 16:20:04.000 TIME INCREMENT : 0 0 0 0.416667E-01 0 ! (day hr min sec ms) NUMBER OF RECORDS : 17 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII NUMBER OF CHANNELS : 13 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ---------------------------- --------------- -------------- -------------- 1 Sample_Number n/a 105 121 2 Pressure decibar 2.4 401.3 3 Temperature:Primary 'deg C (ITS90)' 4.7512 8.631 4 PAR uE/m^2/sec 1.9 21.2 5 Transmissivity %/metre 45.6 63.9 6 Oxygen:Dissolved mL/L 1.501 6.558 7 Salinity:Bottle PSS-78 32.5879 33.9674 8 Phosphate umol/L 0.76 2.82 9 Nitrate_plus_Nitrite umol/L 5.8 40.4 10 Silicate umol/L 6.6 78.5 11 Chlorophyll:Extracted mg/m^3 0.18 0.5 12 Nitrogen:Dissolved:Organic umol/L 2.4 6.1 13 Dimethyl_Sulphide nmol/L 0 4.48 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 9 F ' ' 4 4 -99 ' ' 7 F ' ' 1 5 -99 ' ' 6 F ' ' 1 6 -99 ' ' 8 F ' ' 3 7 -99 ' ' 9 F ' ' 4 8 -99 ' ' 7 F ' ' 2 9 -99 ' ' 6 F ' ' 1 10 -99 ' ' 6 F ' ' 1 11 -99 ' ' 7 F ' ' 2 12 -99 ' ' ' ' F7.1 R4 ' ' 13 -99 ' ' ' ' F7.2 R4 ' ' $END *ADMINISTRATION MISSION : 1998-03 AGENCY : IOS, Ocean Science and Productivity, Sidney, BC COUNTRY : Canada PROJECT : Line P SCIENTIST : Whitney F. PLATFORM : John P. Tully *LOCATION GEOGRAPHIC AREA : N.E. Pacific STATION : MP12 EVENT NUMBER : 41 LATITUDE : 48 58.16000 N ! (deg min) LONGITUDE : 130 40.13000 W ! (deg min) *COMMENTS Salinity samples 119 to 121 were not taken. Collection method: ------------------ A rosette, holding 24 ten-litre water samplers, with a CTD was used. Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. Nutrient samples are analyzed fresh on board using a Technicon AAII auto- analyzer following methods described in Barwell-Clarke and Whitney (1996). Chlorophyll was extracted with 90% acetone and analyzed fluorimetrically. For DMS methods see file "Method 1996 to 1999 for Dimethylsulfide Analysis.doc" in directory \\OSD_Data_Archive\Cruise_Data\Documents\Analysis Reference Papers\. . References: 1. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 2. J. Barwell-Clarke and F. Whitney. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. 3. Minkley, B.G., and F.A. Whitney. 2001. Summary of Hydrographic/CTD Observations Made Along Line P and at Station P: 1991-1999. Canadian Data Report of Hydrography and Ocean Sciences 156: 45 pp. *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- MERGE 2.3 1999/01/19 11:35:01 17 17 REMOVECH 3.1 1999/02/04 15:30:13 17 17 CALIB 7.5 1999/04/21 10:04:40 17 17 CLEAN 2.8.1 2000/03/24 15:41:56 17 17 REMOVECH 6.0 2003/04/29 11:24:36 17 17 HDREDIT2 1.6 2003/04/29 11:27:35 ? ? CLEAN 4.2 2003/04/29 11:27:52 17 17 SORT 3.4.1 2004/04/14 08:32:40 17 17 SORT 3.6 2013/06/14 16:10:39 17 17 MERGE 3.5 2013/06/14 16:11:13 17 17 SORT 3.6 2013/06/14 16:12:23 17 17 HDREDIT2 2.6 2013/06/14 16:12:30 ? ? CLEAN 5.1 2013/06/14 16:12:54 17 17 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:14:22 17 17 REMOVECH 8.2 2014/02/03 17:02:42 17 17 $END $REMARKS -The following MERGE parameters were used: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: pressure, Temperature:Primary, Salinity:T0:C0, Irradiance_PAR, Transmissivity, Dissolved_Oxygen:vol, Flask_Number, Salinity:Bottle Secondary Channels to Include: Phosphate, Nitrate, Silicate, Ammonia, Chlorophyll Primary file : d:\data\1998\9803\98030041.hyd Secondary file: d:\data\1998\9803\98030041.ios -The following CHANNEL(S) were removed from file. Ammonia -The following CALIB parameters were used: Calibration type = C Pressure offset = 0.0 Calibration file = d:\data\1998\9803\9803oxy.cor CLEAN functions: - Reset #RECS, MIN & MAX values in header. -The following CHANNEL(S) were removed from file. Flask_Number CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. - Remove Sea-Bird comments from the header. -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel -SORT parameters: 2013/06/14 16:10:39 Sorted in ascending order of channel Sample_Number -The following MERGE parameters were used: 2013/06/14 16:11:13 Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Secondary Primary Channels to Include: ALL Secondary Channels to Include: Carbon:Dissolved:Organic, Nitrogen:Dissolved:Organic, Dimethyl_Sulphide Primary file : P:\John Pages Archive\1998-03\DMS, DON\1998-03-0041.srt_che Secondary file: P:\John Pages Archive\1998-03\DMS, DON\1998-03-0041.srt_ios Comments from secondary file: P:\John Pages Archive\1998-03\DMS, DON\1998-03-0041.srt_ios ----------------------------------------------------------- -SORT parameters: 2013/06/14 16:11:05 Sorted in ascending order of channel Sample_Number -SORT parameters: 2013/06/14 16:12:23 Sorted in ascending order of channel Pressure -HEADER EDITS: 2013/06/14 16:12:30 Applied edit header: P:\John Pages Archive\DMS_Methods.txt -CLEAN functions: 2013/06/14 16:12:54 20 Reset #RECS, MIN & MAX values in header. Delete Empty Channels: 1 deleted. -REMOVECH 2014/02/03 17:02:42 The following CHANNEL(S) were removed: Salinity:T0:C0 [PSS-78] $END *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ------------------------- ------ ---- ------ ------------ Dissolved_Oxygen:volume ml/l 10 -99 () (0 0.9988) $END *INSTRUMENT TYPE : Bottle MODEL : Niskin 10 Litre !-1-- --2--- ---3---- --4--- --5-- ---6--- ---7---- --8--- --9-- --10- --11-- --12-- --13-- !Samp Pressu Temperat PAR Trans Oxygen: Salinity Phosph Nitra Silic Chloro Nitrog Dimeth !le_ re ure: missi Dissolv :Bottle ate te_ ate phyll: en: yl_ !Numb Primary vity ed plus_ Extrac Dissol Sulphi !er Nitri ted ved:Or de ! te ganic !---- ------ -------- ------ ----- ------- -------- ------ ----- ----- ------ ------ ------ *END OF HEADER 121 2.4 8.6310 21.2 45.6 6.558 -99.0000 0.77 5.8 6.8 0.49 4.1 2.75 120 6.1 8.6232 12.0 55.3 6.522 -99.0000 0.77 5.8 6.6 0.47 -99.0 2.47 119 11.0 8.6145 7.4 56.2 6.524 -99.0000 0.77 5.8 6.8 0.50 4.0 4.48 118 20.7 8.6139 5.2 56.2 6.521 32.5940 0.76 5.8 6.7 0.49 4.1 3.61 117 30.2 8.4843 3.9 56.5 6.543 32.5900 0.79 6.1 7.0 0.49 -99.0 2.78 116 41.3 8.4439 2.8 56.6 6.554 32.5879 0.81 6.4 7.2 0.47 4.4 2.38 115 51.6 8.4231 2.1 56.6 6.531 32.5890 0.80 6.6 7.4 0.49 -99.0 2.46 114 59.4 8.4208 1.9 56.7 6.535 32.5888 0.80 6.5 7.4 0.46 4.1 1.95 113 80.5 8.4042 1.9 61.0 5.832 32.8342 1.05 11.0 12.3 0.22 -99.0 0.80 112 100.0 7.9022 1.9 62.6 4.719 33.3429 1.52 19.4 22.5 0.18 6.1 0.50 111 125.3 7.3940 1.9 63.2 3.989 33.6951 1.82 25.1 32.3 -99.00 -99.0 0.28 110 147.6 7.1507 1.9 63.4 3.754 33.8249 1.92 26.8 36.9 -99.00 3.7 0.22 109 174.6 6.9273 1.9 63.4 3.633 33.8856 1.97 27.9 40.5 -99.00 -99.0 0.00 108 199.2 6.7841 1.9 63.5 3.496 33.9004 2.02 28.7 42.7 -99.00 2.8 0.00 107 250.3 6.0666 1.9 63.5 2.971 33.9085 2.26 32.0 52.2 -99.00 -99.0 0.00 106 299.7 5.4042 1.9 63.7 2.416 33.9088 2.49 35.4 61.9 -99.00 2.4 0.00 105 401.3 4.7512 1.9 63.9 1.501 33.9674 2.82 40.4 78.5 -99.00 2.7 0.00