*2013/12/16 15:13:47.30 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 1997/10/12 02:22:44.000 NUMBER OF RECORDS : 4 DATA DESCRIPTION : Bottle:Rosette:Up:Stop FILE TYPE : ASCII NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ----------------- --------- -------------- -------------- 1 Sample_Number n/a 429 432 2 Salinity:Bottle PSS-78 30.621 31.4422 3 Pressure decibar 150.503 217.833 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 F I 0 2 -99 ' ' 10 F ' ' 4 3 -99 ' ' 11 F ' ' 3 $END *ADMINISTRATION MISSION : 1997-38 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Inlets SCIENTIST : Stucchi D. PLATFORM : Vector *LOCATION STATION : D06A EVENT NUMBER : 94 LATITUDE : 48 45.83000 N ! (deg min) LONGITUDE : 123 2.34000 W ! (deg min) WATER DEPTH : 239 *INSTRUMENT TYPE : Bottle MODEL : Niskin 10 Litre SERIAL : 59724 ! custom item *COMMENTS Collection method: ------------------ A rosette, holding 24 ten-litre water samplers, with a CTD was used. Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. References: 1. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- CLEAN 2.2 1997/10/12 03:30:26 4 4 REMOVECH 3.2 2000/01/11 11:59:13 4 4 HDREDIT2 1.8 2003/10/21 14:29:16 ? ? CLEAN 4.5 2003/10/21 14:30:05 4 4 SORT 3.4.1 2004/04/13 17:04:04 4 4 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:13:47 4 4 $END $REMARKS CLEAN functions performed: - Reset #RECS, MIN & MAX values in header. -The following CHANNEL(S) were removed from file. Salinity:Primary Salinity:Secondary TEMPERATURE:SECONDARY Temperature:Primary SALINITY:T0:C0 SALINITY:T1:C1 TEMPERATURE:SAMPLE DISSOLVED_OXYGEN:MASS THIOSULFATE_TITER FLASK_NUMBER FLASK_VOLUME BLANK STANDARD TRANSMISSIVITY SALINITY:CTD TEMPERATURE:CTD CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel $END !-1-- ----2---- ----3----- !Samp Salinity: Pressure !le_ Bottle !Numb !er !---- --------- ---------- *END OF HEADER 432 30.6210 150.503 431 31.2898 175.854 430 31.4010 200.180 429 31.4422 217.833