*2025/02/12 11:41:10.21 *IOS HEADER VERSION 2.0 2016/04/28 2016/06/13 IVF16 *FILE START TIME : UTC 1997/08/13 06:59:10.000 TIME INCREMENT : 0 0 0 0.5 0 ! (day hr min sec ms) NUMBER OF RECORDS : 1 DATA DESCRIPTION : Bottle:Wire + CTD:Down FILE TYPE : ASCII NUMBER OF CHANNELS : 6 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ---------------------- --------------- -------------- -------------- 1 Depth metres 175.063 175.063 2 Temperature:Primary 'deg C (ITS90)' 8.3952 8.3952 3 Salinity:T0:C0 PSS-78 27.6921 27.6921 4 Transmissivity %/metre 8.7 8.7 5 Salinity:Bottle PSS-78 27.7085 27.7085 6 Flag:Salinity:Bottle n/a $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 ' ' ' ' 6 F ' ' 1 2 -99 ' ' 9 F ' ' 4 3 -99 ' ' 9 F ' ' 4 4 -99 ' ' 6 F ' ' 1 5 -9.9 ' ' 9 F R4 4 6 0 ' ' 2 NQ C ' ' $END $REMARKS Flag channels initialized with zeros. Non-zero values have the following significance: -------------------------------------------------------------------------------------- 1 = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). 2 = Acceptable measurement (not normally used). 3 = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). 4 = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). 5 = Not reported (lost sample; unredeemably bad measurement). 6 = Mean of replicate measurements. 7 = Manual chromatographic peak measurement. 8 = Irregular digital chromatographic peak integration. 9 = Sample not drawn for this measurement from this bottle (not normally used). -------------------------------------------------------------------------------------- $END *ADMINISTRATION MISSION : 1997-36 AGENCY : PBS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Red Tide SCIENTIST : Forbes R. PLATFORM : Revisor *LOCATION GEOGRAPHIC AREA : Mainland B.C. Inlets STATION : 001 EVENT NUMBER : 1 LATITUDE : 50 11.45000 N ! (deg min) LONGITUDE : 123 47.08100 W ! (deg min) *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-19 SERIAL NUMBER : 1294 $TABLE: SENSORS ! Name Abs Depth Serial No ! ---- -------------- ---------- ' ' ' ' ' ' $END $REMARKS SOFTWARE VERSION 4.024 $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SBE_IOS 2.7 2004/01/13 15:03:37 1652 1652 SHIFTDAT 3.3 2004/01/13 17:08:49 ? ? DELETE 6.3 2004/01/13 17:14:00 1652 656 CTDEDIT 4.50 2004/01/15 11:32:30 656 492 CALIB 11.3 2004/01/16 09:23:30 492 492 BINAVE 4.0.1 2004/01/16 09:23:45 492 176 REMOVECH 6.0 2004/01/16 09:44:37 176 176 HDREDIT2 1.9 2004/01/16 10:06:15 ? ? DERIVEDQ 3.2 2004/01/22 09:14:48 176 176 CLEAN 4.5 2004/01/22 09:14:57 ? ? THIN 2.13 2004/01/22 09:15:15 176 1 MERGE 3.1 2004/01/22 09:24:05 1 1 HDREDIT2 1.9 2004/01/22 10:17:14 ? ? CHANGE_FLAGS 1.0 2013/07/29 14:27:40 1 1 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:13:36 1 1 CHANGE_FLAGS 2.0 2014/11/20 09:51:58 1 1 HDREDIT2 3.2 2025/02/12 11:41:10 ? ? $END $REMARKS -The following SHIFT parameters were used. Shift Channel: Temperature:Primary # of Records to Advance (-ve for Delay): At REC# 0 Shift= 1.40 Salinity was recalculated after shift -The following DELETE parameters were used: Surface Record Removal: Low Sal & Last Press Min Maximum Surface Pressure (relative): 10.00 Minimum Surface Salinity: 2.000 Surface Swell Pressure Tolerance: 0.50 Pressure filtered over width: 5 Swells deleted. Warning message if pressure difference of 2.00 Slow Drop Rate NOT deleted. -The following CALIB parameters were used: Calibration type = Calculate Mode: ONLY - calibration specs from Cal File only. Salinity is computed Calibration file = Q:\Cruise_Data\9736\doc\9736-recal.CCF Calibrations applied: Ch Name Units Fmla Coefficents -- ----------------------------- --------- --- ----------------------------- 7 Salinity:T0:C0 PSS-78 10 -0.9000000E-02 0.1000000E+01 -The following BINAVE parameters were used: Bin channel = Pressure:StrainGauge Averaging interval = 1.00 Minimum bin value = 0.000 Average value was used Interpolated values were NOT used for empty bins Channel 'NUMBER_OF_BIN_RECORDS' was added to file. -The following CHANNEL(S) were removed from file. Scan_Number Conductivity:Primary Descent_Rate Flag -The following DERIVEQ parameters were used Reference channel for pressure is: Pressure Reference channel for temperature is: Temperature:Primary Reference channel for conductivity ratio is: Conductivity:Primary Reference channel for salinity is: Salinity:T0:C0 Reference channel for oxygen is: Dissolved_Oxygen:volume Computed properties Derived Properties Ref Press Temp Type Replace ------------------ --------- --------- ------- Depth Insitu n/a YES CLEAN functions: - Remove Sea-Bird comments from the header. -The following THIN parameters were used: Thin by selecting parameter values Reference Channel: Depth List of Values read from file: ddepths.txt Tolerance for finding values: 1.000 Closest Value within Tolerance will be Output -The following MERGE parameters were used: Merge Channel: Depth Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Secondary Primary Channels to Include: Temperature:Primary, Salinity:T0:C0, Transmissivity Secondary Channels to Include: Nitrate_plus_nitrite, Flag:Nitrate_plus_nitrite, Silicate, Flag:Silicate, Phosphate, Flag:Phosphate, Phaeo-Pigment:Extracted, Flag:Phaeophytin, Chlorophyll:Extracted, Flag:Chlorophyll, Salinity:Bottle, Flag:Salinity:Bottle Primary file : Q:\Cruise_Data\9736\test\97360001.ctdthn Secondary file: Q:\Cruise_Data\9736\test\97360001.mrg -HEADER EDITS: 2025/02/12 11:41:10 - none. $END *COMMENTS CTDEDIT was used to remove surface records to 1db and a few records from the bottom of the cast; salinity was cleaned very lightly. ********************************************************************* SEACAT salinity is prone to error due to mismatch of conductivity and temperature response times. These errors are likely to be larger than the calibration errors. Salinity should be considered +/-0.05psu in areas of high gradients and +/-0.01psu elsewhere. The transmissivity data is unedited. ********************************************************************* Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. The bottle depths are approximate. The bottles was fired during a cast that followed the CTD cast. *CALIBRATION $TABLE: CALCULATED CHANNELS ! Name Units Fmla Pad Coefficients ! ---------------- -------- ---- ------ ------------ Salinity:T0:C0 PSS-78 10 -99 () (-0.9E-02 1) $END !--1-- ---2---- ---3---- --4-- ---5---- 6 !Depth Temperat Salinity Trans Salinity F ! ure: :T0:C0 missi :Bottle l ! Primary vity ~ ! l ! e !----- -------- -------- ----- -------- - *END OF HEADER 175.1 8.3952 27.6921 8.7 27.7085 0