*2017/09/21 16:13:36.65 *IOS HEADER VERSION 2.0 2016/04/28 2016/06/13 IVF16 *FILE START TIME : UTC 1997/07/20 19:50:00.000 NUMBER OF RECORDS : 20 DATA DESCRIPTION : Bottle:Rosette:Up:Stop FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------------ --------- -------------- -------------- 1 Sample_Number n/a 430 449 2 Pressure decibar 1.4 1287.5 3 Oxygen:Dissolved mL/L 0.233 7.067 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 8 F ' ' 3 $END $REMARKS Raw data in file 97130104 VI03 = 10.03 ! Volume of iodate standard (cm**3) NI03 = 0.01013542 ! Normalitity of iodate standard VREG = 2.0 ! Volume of sample displaced by reagents (cm**3) DOREG = 0.0017 ! Absolute amount of O2 added with reagents (ml) UFLAG = -1 ! 0|-1, -1 indicates DO_mass is valid $END *ADMINISTRATION MISSION : 1997-13 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Laperouse, GLOBEC SCIENTIST : Thomson R.E. PLATFORM : John P. Tully *LOCATION STATION : LE08 EVENT NUMBER : 104 LATITUDE : 48 40.21700 N ! (deg min) LONGITUDE : 126 38.52100 W ! (deg min) WATER DEPTH : 1304 *INSTRUMENT TYPE : Bottle MODEL : Niskin 10 litre $REMARKS Dissolved oxygen concentration determined using an automated titration system consisting of a Brinkman Dosimat (model 665) and a PC 900 Colorimeter. $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- AutoOxy.bas 2.1 1997/07/20 19:01:45 ' ' 20 CLEAN 2.2 1997/07/21 18:34:00 20 20 REMOVECH 3.2 2000/01/11 09:54:23 20 20 HDREDIT2 1.8 2003/10/20 14:15:10 ? ? CLEAN 4.5 2003/10/20 14:18:29 20 20 SORT 3.4.1 2004/04/13 16:59:31 20 20 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:12:32 20 20 HDREDIT2 3.1.1 2017/09/21 16:13:36 ? ? $END $REMARKS C.H. Culbertson's paper on Dissolved Oxygen in the 'Woce Hydrographic Program Operations and Methods - July 1991' CLEAN functions performed: - Reset #RECS, MIN & MAX values in header. -The following CHANNEL(S) were removed from file. Temperature:Sample Dissolved_oxygen:mass THIOSULFATE_TITER FLASK_NUMBER FLASK_VOLUME BLANK STANDARD SALINITY:CTD TEMPERATURE:CTD CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel -HEADER EDITS: 2017/09/21 16:13:36 Applied edit header: D:\HourstonR_2\Data\iosshell\1997-13.hdr $END *COMMENTS Oxygen samples 431, 437 and 443 had to be warmed to remove stopper, and had air bubble in flask. Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. !-1-- --2--- ---3--- !Samp Pressu Oxygen: !le_ re Dissolv !Numb ed !er !---- ------ ------- *END OF HEADER 449 1.4 6.021 448 10.0 6.033 447 20.5 6.840 446 30.3 7.067 445 50.7 6.510 444 75.0 5.767 443 100.0 3.566 442 125.2 3.027 441 149.3 2.581 440 174.3 2.072 439 199.5 1.949 438 249.4 1.933 437 299.0 1.730 436 398.4 1.124 435 498.6 0.774 434 601.0 0.538 433 797.2 0.262 432 998.9 0.233 431 1201.1 0.443 430 1287.5 0.449