*2017/09/21 16:13:36.33 *IOS HEADER VERSION 2.0 2016/04/28 2016/06/13 IVF16 *FILE START TIME : UTC 1997/07/17 09:53:00.000 NUMBER OF RECORDS : 19 DATA DESCRIPTION : Bottle:Rosette:Up:Stop FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------------ --------- -------------- -------------- 1 Sample_Number n/a 31 49 2 Pressure decibar 0.2 1002.3 3 Oxygen:Dissolved mL/L 0.291 7.349 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 8 F ' ' 3 $END $REMARKS Raw data in file 97130022 VI03 = 10.03 ! Volume of iodate standard (cm**3) NI03 = 0.01013542 ! Normalitity of iodate standard VREG = 2.0 ! Volume of sample displaced by reagents (cm**3) DOREG = 0.0017 ! Absolute amount of O2 added with reagents (ml) UFLAG = -1 ! 0|-1, -1 indicates DO_mass is valid $END *ADMINISTRATION MISSION : 1997-13 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Laperouse, GLOBEC SCIENTIST : Thomson R.E. PLATFORM : John P. Tully *LOCATION STATION : LG06 EVENT NUMBER : 22 LATITUDE : 49 3.35000 N ! (deg min) LONGITUDE : 127 1.48000 W ! (deg min) WATER DEPTH : 1003 *INSTRUMENT TYPE : Bottle MODEL : Niskin 10 litre $REMARKS Dissolved oxygen concentration determined using an automated titration system consisting of a Brinkman Dosimat (model 665) and a PC 900 Colorimeter. $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- AutoOxy.bas 2.1 1997/07/17 13:53:01 ' ' 18 CLEAN 2.2 1997/07/21 18:33:50 19 19 REMOVECH 3.2 2000/01/11 09:54:14 19 19 HDREDIT2 1.8 2003/10/20 14:15:08 ? ? CLEAN 4.5 2003/10/20 14:18:27 19 19 SORT 3.4.1 2004/04/13 16:57:41 19 19 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:12:31 19 19 HDREDIT2 3.1.1 2017/09/21 16:13:36 ? ? $END $REMARKS C.H. Culbertson's paper on Dissolved Oxygen in the 'Woce Hydrographic Program Operations and Methods - July 1991' CLEAN functions performed: - Reset #RECS, MIN & MAX values in header. -The following CHANNEL(S) were removed from file. Temperature:Sample Dissolved_oxygen:mass Thiosulfate_titer Flask_Number Flask_Volume Blank Standard SALINITY:CTD TEMPERATURE:CTD CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel -HEADER EDITS: 2017/09/21 16:13:36 Applied edit header: D:\HourstonR_2\Data\iosshell\1997-13.hdr $END *COMMENTS Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. !-1-- --2--- ---3--- !Samp Pressu Oxygen: !le_ re Dissolv !Numb ed !er !---- ------ ------- *END OF HEADER 49 0.2 6.086 48 11.9 6.105 47 21.1 7.121 46 28.1 7.349 45 48.8 6.378 44 75.7 6.059 43 100.1 3.967 42 120.6 2.944 41 149.6 2.723 40 175.1 2.622 39 194.8 2.535 38 250.1 2.175 37 299.4 1.893 36 398.6 1.282 35 499.9 0.819 34 599.6 0.793 33 798.0 0.316 32 899.8 0.291 31 1002.3 0.346