*2013/12/16 15:11:48.16 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 1997/03/13 08:25:00.000 NUMBER OF RECORDS : 12 DATA DESCRIPTION : Bottle:Rosette:Up:Stop FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------------ --------- -------------- -------------- 1 Sample_Number n/a 122 133 2 Pressure decibar 1.8 120 3 Oxygen:Dissolved mL/L 0.308 7.714 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 8 F ' ' 3 $END $REMARKS Raw data in file 97040022 VI03 = 10.03 ! Volume of iodate standard (cm**3) NI03 = .01013679 ! Normalitity of iodate standard VREG = 2.0 ! Volume of sample displaced by reagents (cm**3) DOREG = 0.0017 ! Absolute amount of O2 added with reagents (ml) UFLAG = -1 ! 0|-1, -1 indicates DO_mass is valid $END *ADMINISTRATION MISSION : 1997-04 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : GLOBEC SCIENTIST : Thomson R.E. PLATFORM : John P. Tully *LOCATION STATION : EFF07 EVENT NUMBER : 22 LATITUDE : 49 1.29000 N ! (deg min) LONGITUDE : 125 9.42000 W ! (deg min) WATER DEPTH : 121 *INSTRUMENT TYPE : Bottle MODEL : Niskin 10 litre $REMARKS Dissolved oxygen concentration determined using an automated titration system consisting of a Brinkman Dosimat (model 665) and a PC 900 Colorimeter. $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- AutoOxy.bas 2.0 1997/03/13 16:19:41 ' ' 12 CLEAN 2.0 1997/03/14 05:20:45 12 12 REMOVECH 3.2 2000/01/11 09:34:46 12 12 HDREDIT2 1.8 2003/10/16 17:10:18 ? ? MERGE 3.1 2003/10/16 17:13:51 12 12 HDREDIT2 1.8 2003/10/16 17:14:50 ? ? CLEAN 4.5 2003/10/16 17:15:21 12 12 SORT 3.4.1 2004/04/13 16:45:50 12 12 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:11:48 12 12 $END $REMARKS C.H. Culbertson's paper on Dissolved Oxygen in the 'Woce Hydrographic Program Operations and Methods - July 1991' -The following CLEAN parameters were used. Reset #RECS, MIN & MAX values in header. -The following CHANNEL(S) were removed from file. Temperature:Sample Dissolved_oxygen:mass Thiosulfate_titer Flask_Number Flask_Volume Blank Standard Salinity:CTD TEMPERATURE:CTD -MERGE *** Secondary file not found *** Primary file : H:\New_Archive\1997\1997-04\hydro\97040022.fix Secondary file: H:\New_Archive\1997\1997-04\hydro\97040022.ios CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel $END *COMMENTS Sample #127 oxygen poor, air bubble on lens. Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. !-1-- --2--- ---3--- !Samp Pressu Oxygen: !le_ re Dissolv !Numb ed !er !---- ------ ------- *END OF HEADER 133 1.8 7.714 132 10.5 5.830 131 30.4 5.635 130 40.3 5.059 129 50.3 4.077 128 60.2 4.021 127 70.2 4.380 126 80.2 3.840 125 90.1 1.791 124 110.0 0.464 123 114.9 0.308 122 120.0 0.349