*2013/12/16 15:11:48.13 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 1997/03/13 06:51:00.000 NUMBER OF RECORDS : 18 DATA DESCRIPTION : Bottle:Rosette:Up:Stop FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 4 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------------ --------- -------------- -------------- 1 Sample_Number n/a 88 106 2 Pressure decibar 1.5 193.1 3 Oxygen:Dissolved mL/L 0.138 8.951 4 Salinity:Bottle PSS-78 32.8234 32.832 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 8 F ' ' 3 4 -99 ' ' 9 F ' ' 4 $END $REMARKS Raw data in file 97040018 VI03 = 10.03 ! Volume of iodate standard (cm**3) NI03 = .01013679 ! Normalitity of iodate standard VREG = 2.0 ! Volume of sample displaced by reagents (cm**3) DOREG = 0.0017 ! Absolute amount of O2 added with reagents (ml) UFLAG = -1 ! 0|-1, -1 indicates DO_mass is valid $END *ADMINISTRATION MISSION : 1997-04 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : GLOBEC SCIENTIST : Thomson R.E. PLATFORM : John P. Tully *LOCATION STATION : EFF05A EVENT NUMBER : 18 LATITUDE : 49 2.83000 N ! (deg min) LONGITUDE : 125 9.12000 W ! (deg min) WATER DEPTH : 200 *INSTRUMENT TYPE : Bottle MODEL : Niskin 10 litre $REMARKS Dissolved oxygen concentration determined using an automated titration system consisting of a Brinkman Dosimat (model 665) and a PC 900 Colorimeter. $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- AutoOxy.bas 2.0 1997/03/13 14:15:59 ' ' 18 CLEAN 2.0 1997/03/14 05:20:45 18 18 REMOVECH 3.2 2000/01/11 09:34:46 18 18 HDREDIT2 1.8 2003/10/16 17:10:17 ? ? MERGE 3.1 2003/10/16 17:13:51 18 18 HDREDIT2 1.8 2003/10/16 17:14:50 ? ? CLEAN 4.5 2003/10/16 17:15:21 18 18 SORT 3.4.1 2004/04/13 16:45:47 18 18 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:11:48 18 18 $END $REMARKS C.H. Culbertson's paper on Dissolved Oxygen in the 'Woce Hydrographic Program Operations and Methods - July 1991' -The following CLEAN parameters were used. Reset #RECS, MIN & MAX values in header. -The following CHANNEL(S) were removed from file. Temperature:Sample Dissolved_oxygen:mass Thiosulfate_titer Flask_Number Flask_Volume Blank Standard Salinity:CTD TEMPERATURE:CTD -MERGE *** Secondary file not found *** Primary file : H:\New_Archive\1997\1997-04\hydro\97040018.fix Secondary file: H:\New_Archive\1997\1997-04\hydro\97040018.ios CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel $END *COMMENTS Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. !-1-- --2--- ---3--- ---4---- !Samp Pressu Oxygen: Salinity !le_ re Dissolv :Bottle !Numb ed !er !---- ------ ------- -------- *END OF HEADER 106 1.5 8.951 -99.0000 105 10.2 5.543 -99.0000 104 30.2 5.033 -99.0000 103 40.2 4.295 -99.0000 102 50.2 3.886 -99.0000 101 60.1 4.135 -99.0000 100 70.1 4.117 -99.0000 99 80.1 3.074 -99.0000 97 90.2 1.059 -99.0000 96 100.2 0.706 -99.0000 95 110.2 0.589 -99.0000 94 120.3 0.466 -99.0000 93 129.9 0.438 -99.0000 92 149.1 0.450 -99.0000 91 170.0 0.354 32.8234 90 190.0 0.234 32.8320 89 192.3 0.162 32.8302 88 193.1 0.138 32.8301