*2013/12/16 15:10:16.10 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : PDT 1996/06/06 10:14:00.000 NUMBER OF RECORDS : 7 DATA DESCRIPTION : Bottle:Rosette:Up:Stop FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------------ --------- -------------- -------------- 1 Bottle_Number n/a 1 7 2 Pressure decibar 1.8 100.3 3 Oxygen:Dissolved mL/L 2.492 8.096 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 0 ' ' 5 I I 0 2 0 ' ' 7 F ' ' 1 3 -99 ' ' 8 F ' ' 3 $END $REMARKS Raw data in file 96130013 VI03 = 10.025 ! Volume of iodate standard (cm**3) NI03 = .010126 ! Normality of iodate standard VREG = 2.0 ! Volume of sample displaced by reagents (cm**3) DOREG = 0.0017 ! Absolute amount of O2 added with reagents (ml) UFLAG = -1 ! 0|-1, -1 indicates DO_mass is valid $END *ADMINISTRATION MISSION : 1996-13 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Laperouse, JGOFS SCIENTIST : Mackas D. PLATFORM : John P. Tully *LOCATION STATION : LB04 EVENT NUMBER : 13 LATITUDE : 48 35.60000 N ! (deg min) LONGITUDE : 125 9.01000 W ! (deg min) WATER DEPTH : 111 *INSTRUMENT TYPE : Bottle MODEL : Niskin 10 litre $REMARKS Dissolved oxygen concentration determined using an automated titration system consisting of a Brinkman Dosimat (model 665) and a PC 900 Colorimeter. $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- AutoOxy.bas 1.8 1996/06/07 02:55:41 ' ' 7 CLEAN 2.2 1997/03/26 13:40:48 7 7 REMOVECH 6.0 2002/03/08 13:55:57 7 7 HDREDIT2 1.8 2003/10/14 14:49:27 ? ? CLEAN 4.5 2003/10/14 15:39:58 7 7 MERGE 3.1 2003/10/14 16:07:40 7 7 CLEAN 4.5 2003/10/14 18:18:32 7 7 SORT 3.4.1 2004/04/13 15:39:11 7 7 HDREDIT2 2.0 2004/05/19 14:44:02 ? ? CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:10:16 7 7 $END $REMARKS C.H. Culbertson's paper on Dissolved Oxygen in the 'Woce Hydrographic Program Operations and Methods - July 1991' CLEAN functions performed: - Reset #RECS, MIN & MAX values in header. -The following CHANNEL(S) were removed from file. Temperature:Sample Salinity:CTD Dissolved_Oxygen:mass Thiosulfate_titer Flask_Number Flask_Volume Blank Standard CLEAN functions: - Reset #RECS, MIN & MAX values in header. -MERGE *** Secondary file not found *** Primary file : H:\New_Archive\1996\1996-13\hydro\96130013.cln Secondary file: H:\New_Archive\1996\1996-13\hydro\96130013.clnchl CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in Channel: Oxygen:Dissoved [mL/L] -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel $END !-1-- --2--- ---3--- !Bott Pressu Oxygen: !le_ re Dissolv !Numb ed !er !---- ------ ------- *END OF HEADER 7 1.8 8.096 6 10.5 7.157 5 20.5 6.326 4 30.8 5.274 3 51.0 3.453 2 75.8 2.965 1 100.3 2.492