*2013/12/16 15:09:43.47 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 1996/04/23 06:25:00.000 NUMBER OF RECORDS : 12 DATA DESCRIPTION : Bottle:Rosette:Up:Stop FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------------ --------- -------------- -------------- 1 Bottle_Number n/a 1 12 2 Pressure decibar 0 92 3 Oxygen:Dissolved mL/L 4.213 7.192 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 3 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 7 F ' ' 3 $END $REMARKS Raw data in file 96080172 VI03 = 10.02 ! Volume of iodate standard (cm**3) NI03 = .010123 ! Normality of iodate standard VREG = 2.0 ! Volume of sample displaced by reagents (cm**3) DOREG = 0.0017 ! Absolute amount of O2 added with reagents (ml) UFLAG = -1 ! 0|-1, -1 indicates DO_mass is valid $END *ADMINISTRATION MISSION : 1996-08 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Laperouse, JGOFS, CRD, Effingham Inlet SCIENTIST : Juhasz T. PLATFORM : John P. Tully *LOCATION STATION : EFF10 EVENT NUMBER : 172 LATITUDE : 48 59.85000 N ! (deg min) LONGITUDE : 125 11.22000 W ! (deg min) WATER DEPTH : 95 *INSTRUMENT TYPE : Bottle MODEL : Niskin 10 litre $REMARKS Dissolved oxygen concentration determined using an automated titration system consisting of a Brinkman Dosimat (model 665) and a PC 900 Colorimeter. $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- AutoOxy.bas 1.8 1996/04/23 23:45:11 ' ' 12 CLEAN 2.0 1996/06/04 10:39:35 12 12 SORT 2.3 1997/01/05 11:59:13 12 12 REMOVECH 3.2 2000/01/10 16:20:51 12 12 HDREDIT2 1.7 2003/09/22 15:02:26 ? ? CLEAN 4.4 2003/09/22 15:03:03 12 12 SORT 3.4.1 2004/04/13 15:02:36 12 12 HDREDIT2 2.0 2004/04/28 11:59:33 ? ? CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:09:43 12 12 $END $REMARKS C.H. Culbertson's paper on Dissolved Oxygen in the 'Woce Hydrographic Program Operations and Methods - July 1991' -The following CLEAN parameters were used. Reset #RECS, MIN & MAX values in header. -The following SORT parameters were used. Sorted by channel: pressure Pressure channel sorted according to values in sort channel -The following CHANNEL(S) were removed from file. Temperature:Sample Dissolved_oxygen:mass Thiosulfate_titer Flask_Number Flask_Volume Blank Standard SALINITY:CTD CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel $END !1- --2--- --3--- !Bo Pressu Oxygen !tt re : !~u Dissol !mb ved !er !-- ------ ------ *END OF HEADER 12 0.0 7.192 11 5.6 6.702 10 10.5 6.668 9 14.7 6.547 8 20.0 6.501 7 25.2 6.402 6 30.3 6.237 5 39.6 5.842 4 50.5 5.175 3 60.8 4.313 2 80.8 4.220 1 92.0 4.213