*2013/12/16 15:09:43.00 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 1996/04/14 01:27:00.000 NUMBER OF RECORDS : 16 DATA DESCRIPTION : Bottle:Rosette:Up:Stop FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 4 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------------ --------- -------------- -------------- 1 Bottle_Number n/a 1 16 2 Pressure decibar 1.3 858.1 3 Salinity:Bottle PSS-78 31.6564 34.3287 4 Oxygen:Dissolved mL/L 0.375 6.784 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 3 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 8 F ' ' 4 4 -99 ' ' 7 F ' ' 3 $END $REMARKS Raw data in file 96080024 VI03 = 10.02 ! Volume of iodate standard (cm**3) NI03 = .010123 ! Normality of iodate standard VREG = 2.0 ! Volume of sample displaced by reagents (cm**3) DOREG = 0.0017 ! Absolute amount of O2 added with reagents (ml) UFLAG = -1 ! 0|-1, -1 indicates DO_mass is valid $END *ADMINISTRATION MISSION : 1996-08 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Laperouse, JGOFS, CRD, Effingham Inlet SCIENTIST : Denman K.L. PLATFORM : John P. Tully *LOCATION STATION : LBP6 EVENT NUMBER : 24 LATITUDE : 49 56.27000 N ! (deg min) LONGITUDE : 128 5.62000 W ! (deg min) WATER DEPTH : 785 *INSTRUMENT TYPE : Bottle MODEL : Niskin 10 litre $REMARKS Dissolved oxygen concentration determined using an automated titration system consisting of a Brinkman Dosimat (model 665) and a PC 900 Colorimeter. $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- AutoOxy.bas 1.8 1996/04/14 17:59:40 ' ' 16 CLEAN 2.0 1996/06/04 10:39:26 16 16 SORT 2.3 1997/01/05 11:59:07 16 16 REMOVECH 3.2 2000/01/10 16:20:39 16 16 HDREDIT2 1.7 2003/09/22 15:01:24 ? ? CLEAN 4.4 2003/09/22 15:03:02 16 16 SORT 3.4.1 2004/04/13 15:01:15 16 16 HDREDIT2 2.0 2004/04/28 11:58:58 ? ? CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:09:43 16 16 $END $REMARKS C.H. Culbertson's paper on Dissolved Oxygen in the 'Woce Hydrographic Program Operations and Methods - July 1991' -The following CLEAN parameters were used. Reset #RECS, MIN & MAX values in header. -The following SORT parameters were used. Sorted by channel: pressure Pressure channel sorted according to values in sort channel -The following CHANNEL(S) were removed from file. Temperature:Sample Dissolved_oxygen:mass Thiosulfate_titer Flask_Number Flask_Volume Blank Standard SALINITY:CTD CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel $END !1- --2--- ---3--- --4--- !Bo Pressu Salinit Oxygen !tt re y: : !~u Bottle Dissol !mb ved !er !-- ------ ------- ------ *END OF HEADER 16 1.3 31.6584 6.770 15 8.8 31.6564 6.784 14 20.4 31.7054 6.772 13 29.9 31.8995 6.691 12 49.4 32.4735 6.374 11 74.4 32.8558 5.307 10 99.9 33.3740 4.003 9 122.9 33.6586 3.109 8 150.3 33.8068 2.794 7 199.8 33.8970 2.529 6 249.6 33.9494 2.276 5 302.0 33.9372 2.270 4 398.4 34.0312 1.296 3 500.4 34.0912 0.853 2 596.2 34.1512 0.625 1 858.1 34.3287 0.375