*2013/12/16 15:09:41.70 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 1996/10/18 20:55:00.000 NUMBER OF RECORDS : 16 DATA DESCRIPTION : Bottle:Wire FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------------ --------- -------------- -------------- 1 Sample_Number n/a 1 16 2 Pressure decibar 0 34 3 Oxygen:Dissolved mL/L -0.12E-01 6.764 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 8 F ' ' 3 $END $REMARKS Raw data in file 96040021 VI03 = 10.02 ! Volume of iodate standard (cm**3) NI03 = 0.01012923 ! Normality of iodate standard VREG = 2.0 ! Volume of sample displaced by reagents (cm**3) DOREG = 0.0017 ! Absolute amount of O2 added with reagents (ml) UFLAG = 0 ! 0|-1, -1 indicates DO_mass is valid $END *ADMINISTRATION MISSION : 1996-04 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Minette Bay Study SCIENTIST : Stucchi D. PLATFORM : Bull Block *LOCATION STATION : MB EVENT NUMBER : 21 LATITUDE : 54 1.49000 N ! (deg min) LONGITUDE : 128 37.10000 W ! (deg min) WATER DEPTH : 36 *INSTRUMENT TYPE : Bottle MODEL : Niskin 10 litre $REMARKS Dissolved oxygen concentration determined using an automated titration system consisting of a Brinkman Dosimat (model 665) and a PC 900 Colorimeter. $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- AutoOxy.bas 1.9 1996/10/20 01:50:59 ' ' 16 OxyRedo.bas 1.0 1996/11/01 08:15:31 16 16 REMOVECH 3.2 2000/01/14 14:40:26 16 16 HDREDIT2 1.7 2003/09/22 11:29:38 ? ? CLEAN 4.4 2003/09/22 11:30:10 16 16 HDREDIT2 2.0 2004/05/21 14:27:59 ? ? CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:09:41 16 16 $END $REMARKS C.H. Culbertson's paper on Dissolved Oxygen in the 'Woce Hydrographic Program Operations and Methods - July 1991' OxyRedo fixs DO_mass and DO_volumne when incorrect values for VIO3, NIO3, blank, or standard have been entered. Pickling temperatures estimated - DJS. -The following CHANNEL(S) were removed from file. SALINITY:PRIMARY SALINITY:SECONDARY TEMPERATURE:SECONDARY TEMPERATURE:PRIMARY SALINITY:T0:C0 SALINITY:T1:C1 VOLTAGE:SEATECH TRANS_ATTENUATION_COEF FLUOROMETER:SEATECH FLUOROMETER:SEAPOINT FLUOROMETER_SEATECH FLUOROMETER_SEAPOINT Temperature:Sample Dissolved_oxygen:mass Thiosulfate_titer Flask_Number Flask_Volume Blank Standard IRRADIANCE_PAR CHL_FLUORESCENCE TRANSMISSIVITY BOTTLE_NUMBER SALINITY:CTD TEMPERATURE:CTD Temperature CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. $END !-1-- --2--- ---3--- !Samp Pressu Oxygen: !le_ re Dissolv !Numb ed !er !---- ------ ------- *END OF HEADER 1 0.0 6.764 2 0.0 6.543 3 4.0 5.245 4 4.0 5.227 5 9.0 4.684 6 9.0 4.704 7 14.0 4.070 8 14.0 4.086 9 19.0 2.833 10 19.0 2.811 11 24.0 0.061 12 24.0 0.016 13 29.0 0.039 14 29.0 -0.001 15 34.0 -0.001 16 34.0 -0.012