*2004/05/21 14:27:58.98 *IOS HEADER VERSION 1.4 2002/12/04 2002/12/04 *FILE START TIME : PDT 1996/08/08 09:16:00.000 NUMBER OF RECORDS : 7 DATA DESCRIPTION : Bottle:Wire FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum ! -- ------------------ -------- -------------- -------------- 1 Sample_Number n/a 237 243 2 Depth metres 0 55 3 Oxygen:Dissolved mL/L 3.555 7.119 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places ! -- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 8 F ' ' 3 $END $REMARKS Raw data in file 96040020 VI03 = 10.025 ! Volume of iodate standard (cm**3) NI03 = .01013376 ! Normality of iodate standard VREG = 2.0 ! Volume of sample displaced by reagents (cm**3) DOREG = 0.0017 ! Absolute amount of O2 added with reagents (ml) UFLAG = -1 ! 0|-1, -1 indicates DO_mass is valid $END *ADMINISTRATION MISSION : 1996-04 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Minette Bay Study SCIENTIST : Stucchi D. PLATFORM : Bull Block *LOCATION STATION : KA EVENT NUMBER : 20 LATITUDE : 53 59.14000 N ! (deg min) LONGITUDE : 128 39.34000 W ! (deg min) WATER DEPTH : 67 *INSTRUMENT TYPE : Bottle MODEL : Niskin 1.7 litre $REMARKS Dissolved oxygen concentration determined using an automated titration system consisting of a Brinkman Dosimat (model 665) and a PC 900 Colorimeter. $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ----------- ------ ---------- -------- --------- --------- AutoOxy.bas 1.8 1996/08/09 17:41:39 ' ' 7 OxyRedo.bas 1.0 1996/09/09 10:02:47 7 7 OxyRedo.bas 1.0 1996/09/09 10:56:21 7 7 REMOVECH 3.2 2000/01/14 14:40:26 7 7 HDREDIT2 1.7 2003/09/22 11:29:38 ? ? CLEAN 4.4 2003/09/22 11:30:10 7 7 HDREDIT2 2.0 2004/05/21 14:27:58 ? ? $END $REMARKS C.H. Culbertson's paper on Dissolved Oxygen in the 'Woce Hydrographic Program Operations and Methods - July 1991' OxyRedo fixs DO_mass and DO_volumne when incorrect values for VIO3, NIO3, blank, or standard have been entered. OxyRedo fixs DO_mass and DO_volumne when incorrect values for VIO3, NIO3, blank, or standard have been entered. -The following CHANNEL(S) were removed from file. SALINITY:PRIMARY SALINITY:SECONDARY TEMPERATURE:SECONDARY TEMPERATURE:PRIMARY SALINITY:T0:C0 SALINITY:T1:C1 VOLTAGE:SEATECH TRANS_ATTENUATION_COEF FLUOROMETER:SEATECH FLUOROMETER:SEAPOINT FLUOROMETER_SEATECH FLUOROMETER_SEAPOINT Temperature:Sample Dissolved_oxygen:mass Thiosulfate_titer Flask_Number Flask_Volume Blank Standard IRRADIANCE_PAR CHL_FLUORESCENCE TRANSMISSIVITY BOTTLE_NUMBER SALINITY:CTD TEMPERATURE:CTD Temperature CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. $END !-1-- --2--- ---3--- !Samp Depth Oxygen: !le_ Dissolv !Numb ed !er !---- ------ ------- *END OF HEADER 243 0.0 6.936 242 5.0 7.119 241 10.0 5.271 240 20.0 4.682 239 30.0 4.156 238 40.0 3.914 237 55.0 3.555