*2013/12/16 15:09:41.67 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : PDT 1996/08/07 09:54:00.000 NUMBER OF RECORDS : 16 DATA DESCRIPTION : Bottle:Wire FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------------ --------- -------------- -------------- 1 Sample_Number n/a 222 236 2 Pressure decibar 0 35 3 Oxygen:Dissolved mL/L 0.28E-01 6.9 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 8 F ' ' 3 $END $REMARKS Raw data in file 96990018 VI03 = 10.025 ! Volume of iodate standard (cm**3) NI03 = .01013376 ! Normality of iodate standard VREG = 2.0 ! Volume of sample displaced by reagents (cm**3) DOREG = 0.0017 ! Absolute amount of O2 added with reagents (ml) UFLAG = -1 ! 0|-1, -1 indicates DO_mass is valid $END *ADMINISTRATION MISSION : 1996-04 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Minette Bay Study SCIENTIST : Stucchi D. PLATFORM : Bull Block *LOCATION STATION : MB1 EVENT NUMBER : 18 LATITUDE : 54 1.39000 N ! (deg min) LONGITUDE : 128 37.28000 W ! (deg min) WATER DEPTH : 36 *INSTRUMENT TYPE : Bottle MODEL : Niskin 1.7 litre $REMARKS Dissolved oxygen concentration determined using an automated titration system consisting of a Brinkman Dosimat (model 665) and a PC 900 Colorimeter. $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- AutoOxy.bas 1.8 1996/08/08 12:25:45 ' ' 16 OxyRedo.bas 1.0 1996/09/09 10:55:59 16 16 REMOVECH 3.2 2000/01/14 14:40:26 16 16 HDREDIT2 1.7 2003/09/22 11:29:38 ? ? CLEAN 4.4 2003/09/22 11:30:10 16 16 HDREDIT2 2.0 2004/05/21 14:27:54 ? ? CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:09:41 16 16 $END $REMARKS C.H. Culbertson's paper on Dissolved Oxygen in the 'Woce Hydrographic Program Operations and Methods - July 1991' OxyRedo fixs DO_mass and DO_volumne when incorrect values for VIO3, NIO3, blank, or standard have been entered. -The following CHANNEL(S) were removed from file. SALINITY:PRIMARY SALINITY:SECONDARY TEMPERATURE:SECONDARY TEMPERATURE:PRIMARY SALINITY:T0:C0 SALINITY:T1:C1 VOLTAGE:SEATECH TRANS_ATTENUATION_COEF FLUOROMETER:SEATECH FLUOROMETER:SEAPOINT FLUOROMETER_SEATECH FLUOROMETER_SEAPOINT Temperature:Sample Dissolved_oxygen:mass Thiosulfate_titer Flask_Number Flask_Volume Blank Standard IRRADIANCE_PAR CHL_FLUORESCENCE TRANSMISSIVITY BOTTLE_NUMBER SALINITY:CTD TEMPERATURE:CTD Temperature CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. $END !-1-- --2--- ---3--- !Samp Pressu Oxygen: !le_ re Dissolv !Numb ed !er !---- ------ ------- *END OF HEADER 236 0.0 6.900 235 0.0 6.859 234 5.0 6.792 233 5.0 6.809 232 10.0 6.611 231 10.0 6.677 230 15.0 2.220 229 15.0 2.154 228 20.0 0.128 227 20.0 0.152 226 25.0 0.181 225 25.0 0.102 224 30.0 0.096 223 30.0 0.056 222 35.0 0.033 222 35.0 0.028