*2004/05/21 14:27:31.35 *IOS HEADER VERSION 1.4 2002/12/04 2002/12/04 *FILE START TIME : PST 1996/02/06 10:30:00.000 NUMBER OF RECORDS : 7 DATA DESCRIPTION : Bottle:Wire FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 4 $TABLE: CHANNELS ! No Name Units Minimum Maximum ! -- ------------------ -------- -------------- -------------- 1 Sample_Number n/a 149 155 2 Depth metres 0 55 3 Salinity:Bottle PSS-78 28.9747 31.1816 4 Oxygen:Dissolved mL/L 5.8 6.633 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places ! -- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 9 F ' ' 4 4 -99 ' ' 8 F ' ' 3 $END $REMARKS Raw data in file 96040008 VI03 = 10.02 ! Volume of iodate standard (cm**3) NI03 = .010133 ! Normality of iodate standard VREG = 2.0 ! Volume of sample displaced by reagents (cm**3) DOREG = 0.0017 ! Absolute amount of O2 added with reagents (ml) UFLAG = 0 ! 0|-1, -1 indicates DO_mass is valid $END *ADMINISTRATION MISSION : 1996-04 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Minette Bay Study SCIENTIST : Stucchi D. PLATFORM : Bull Block *LOCATION STATION : KA008 EVENT NUMBER : 8 LATITUDE : 53 59.14000 N ! (deg min) LONGITUDE : 128 39.33300 W ! (deg min) WATER DEPTH : 60 *INSTRUMENT TYPE : Bottle MODEL : Niskin 1.7 litre $REMARKS Dissolved oxygen concentration determined using an automated titration system consisting of a Brinkman Dosimat (model 665) and a PC 900 Colorimeter. $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ----------- ------ ---------- -------- --------- --------- AutoOxy.bas 1.8 1996/02/07 16:13:01 ' ' 7 OxyRedo.bas 1.0 1996/02/12 10:46:27 7 7 OxyRedo.bas 1.0 1996/10/15 09:37:34 7 7 REMOVECH 3.2 2000/01/14 14:40:22 7 7 HDREDIT2 1.7 2003/09/22 11:29:37 ? ? CLEAN 4.4 2003/09/22 11:30:10 7 7 HDREDIT2 2.0 2004/05/21 14:27:31 ? ? $END $REMARKS C.H. Culbertson's paper on Dissolved Oxygen in the 'Woce Hydrographic Program Operations and Methods - July 1991' OxyRedo fixs DO_mass and DO_volumne when incorrect values for VIO3, NIO3, blank, or standard have been entered. OxyRedo fixs DO_mass and DO_volumne when incorrect values for VIO3, NIO3, blank, or standard have been entered. -The following CHANNEL(S) were removed from file. SALINITY:PRIMARY SALINITY:SECONDARY TEMPERATURE:SECONDARY TEMPERATURE:PRIMARY SALINITY:T0:C0 SALINITY:T1:C1 VOLTAGE:SEATECH TRANS_ATTENUATION_COEF FLUOROMETER:SEATECH FLUOROMETER:SEAPOINT FLUOROMETER_SEATECH FLUOROMETER_SEAPOINT Temperature:Sample Dissolved_oxygen:mass Thiosulfate_titer Flask_Number Flask_Volume Blank Standard IRRADIANCE_PAR CHL_FLUORESCENCE TRANSMISSIVITY BOTTLE_NUMBER SALINITY:CTD TEMPERATURE:CTD Temperature CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. $END !-1-- --2--- ---3---- ---4--- !Samp Depth Salinity Oxygen: !le_ :Bottle Dissolv !Numb ed !er !---- ------ -------- ------- *END OF HEADER 155 0.0 28.9747 6.633 154 5.0 29.3780 6.562 153 10.0 29.7488 6.449 152 20.0 30.2404 6.440 151 30.0 30.5447 6.365 150 40.0 30.7654 6.288 149 55.0 31.1816 5.800