*2013/12/16 15:09:23.89 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 1995/12/12 17:32:00.000 NUMBER OF RECORDS : 6 DATA DESCRIPTION : Bottle:Rosette FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 4 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------------ --------- -------------- -------------- 1 Sample_Number n/a 1 6 2 Pressure decibar 1 25.1 3 Salinity:Bottle PSS-78 25.3234 30.2176 4 Oxygen:Dissolved mL/L 4.61 5.718 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 9 F ' ' 4 4 -99 ' ' 8 F ' ' 3 $END $REMARKS Raw data in file 95420002 VI03 = 10.02 ! Volume of iodate standard (cm**3) NI03 = .010123 ! Normality of iodate standard VREG = 2.0 ! Volume of sample displaced by reagents (cm**3) DOREG = 0.0017 ! Absolute amount of O2 added with reagents (ml) UFLAG = -1 ! 0|-1, -1 indicates DO_mass is valid $END *ADMINISTRATION MISSION : 1995-42 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Effingham Inlet SCIENTIST : Thomson R.E. PLATFORM : John P. Tully $REMARKS Header Admin section updated RMB $END *LOCATION STATION : EFF01 EVENT NUMBER : 2 LATITUDE : 49 5.58000 N ! (deg min) LONGITUDE : 125 11.64000 W ! (deg min) WATER DEPTH : 28 *INSTRUMENT TYPE : Bottle MODEL : Niskin (10 litre) $REMARKS Dissolved oxygen concentration determined using an automated titration system consisting of a Brinkman Dosimat (model 665) and a PC 900 Colorimeter. $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- AutoOxy.bas 1.8 1995/12/12 14:17:06 ' ' 6 CLEAN 1.1 1996/03/19 13:46:00 6 6 HEADEDIT 1.1 1996/05/23 12:10:12 ' ' ' ' REMOVECH 3.2 2000/01/10 16:15:17 6 6 HDREDIT2 1.6 2003/09/09 11:04:55 ? ? CLEAN 4.4 2003/09/09 11:05:36 6 6 SORT 3.4.1 2004/04/13 14:44:36 6 6 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:09:23 6 6 $END $REMARKS C.H. Culbertson's paper on Dissolved Oxygen in the 'Woce Hydrographic Program Operations and Methods - July 1991' OxyRedo fixs DO_mass and DO_volumne when incorrect values for VIO3, NIO3, blank, or standard have been entered. -The following CLEAN parameters were used. Reset #RECS, MIN & MAX values in header. -The following CHANNEL(S) were removed from file. Temperature:Sample Dissolved_oxygen:mass Thiosulfate_titer Flask_Number Flask_Volume Blank Standard SALINITY:CTD CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel $END *COMMENTS Analyzes methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC900 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. !-1-- --2--- ---3---- ---4--- !Samp Pressu Salinity Oxygen: !le_ re :Bottle Dissolv !Numb ed !er !---- ------ -------- ------- *END OF HEADER 6 1.0 25.3234 5.718 5 5.1 28.9596 5.167 4 9.9 29.7697 5.019 3 15.2 29.8586 5.126 2 19.7 30.0146 4.922 1 25.1 30.2176 4.610