*2013/12/16 15:09:06.06 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 1995/10/05 06:32:00.000 NUMBER OF RECORDS : 8 DATA DESCRIPTION : Bottle:Rosette:Up:Stop FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------------ --------- -------------- -------------- 1 Sample_Number n/a 254 261 2 Pressure decibar 4.4 190.7 3 Oxygen:Dissolved mL/L 1.65 5.265 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 8 F ' ' 3 $END $REMARKS Raw data in file 95300168 VI03 = 10.025 ! Volume of iodate standard (cm**3) NI03 = .01012867 ! Normalitity of iodate standard VREG = 2.0 ! Volume of sample displaced by reagents (cm**3) DOREG = 0.0017 ! Absolute amount of O2 added with reagents (ml) UFLAG = -1 ! 0|-1, -1 indicates DO_mass is valid $END *ADMINISTRATION MISSION : 1995-30 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Laperouse, JGOFS SCIENTIST : Denman K.L. PLATFORM : John P. Tully *LOCATION STATION : D14A EVENT NUMBER : 168 LATITUDE : 48 21.90000 N ! (deg min) LONGITUDE : 124 15.03000 W ! (deg min) WATER DEPTH : 200 *INSTRUMENT TYPE : Bottle MODEL : Niskin 10 litre $REMARKS Dissolved oxygen concentration determined using an automated titration system consisting of a Brinkman Dosimat (model 665) and a PC 900 Colorimeter. $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- AutoOxy.bas 1.5 1995/10/05 14:28:25 ' ' 8 REMOVECH 3.1 1999/03/30 15:45:44 8 8 REMOVECH 3.2 2000/01/10 16:11:05 8 8 HDREDIT2 1.7 2003/09/17 13:26:10 ? ? MERGE 3.0 2003/09/17 13:27:24 8 8 CLEAN 4.4 2003/09/17 13:32:43 8 8 SORT 3.4.1 2004/04/13 14:41:51 8 8 HDREDIT2 2.0 2004/05/19 14:32:25 ? ? CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:09:06 8 8 $END $REMARKS C.H. Culbertson's paper on Dissolved Oxygen in the 'Woce Hydrographic Program Operations and Methods - July 1991' -The following CHANNEL(S) were removed from file. Thiosulfate_titer Flask_Volume Blank Standard -The following CHANNEL(S) were removed from file. Temperature:Sample Dissolved_oxygen:mass THIOSULFATE_TITER Flask_Number FLASK_VOLUME BLANK STANDARD Salinity:CTD -MERGE *** Secondary file not found *** Primary file : H:\New_Archive\1995\1995-30\nuts\95300168.fix Secondary file: H:\New_Archive\1995\1995-30\nuts\95300168.rev CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel $END !-1-- --2--- ---3--- !Samp Pressu Oxygen: !le_ re Dissolv !Numb ed !er !---- ------ ------- *END OF HEADER 261 4.4 5.265 260 15.5 4.580 259 28.0 3.940 258 50.8 3.542 257 74.4 2.598 256 101.4 2.059 255 150.7 1.660 254 190.7 1.650