*2013/12/22 11:36:43.32 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 1995/09/25 19:33:00.000 NUMBER OF RECORDS : 12 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Down FILE TYPE : ASCII NUMBER OF CHANNELS : 4 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------------ --------- -------------- -------------- 1 Sample_Number n/a 404 415 2 Pressure decibar 0 180 3 Salinity PSS-78 28.862 31.294 4 Oxygen:Dissolved umol/kg 14.6 356.7 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' ' ' I5 I ' ' 2 -99 ' ' ' ' F7.1 R4 ' ' 3 -99 ' ' ' ' F8.3 R4 ' ' 4 -99 ' ' ' ' F7.1 R4 ' ' $END *ADMINISTRATION MISSION : 1995-27 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Saanich Inlet SCIENTIST : Stucchi D. PLATFORM : R.B. Young *LOCATION GEOGRAPHIC AREA : Saanich Inlet STATION : S5 EVENT NUMBER : 166 LATITUDE : 48 39.28000 N ! (deg min) LONGITUDE : 123 30.17000 W ! (deg min) *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SPRD2IS 4.9 2012/08/20 14:22:23 12 12 HDREDIT2 2.5.1 2012/08/20 14:31:07 ? ? SORT 3.5 2012/08/20 14:32:40 12 12 CLEAN 5.0.4 2012/08/20 14:33:27 12 12 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/22 11:36:43 12 12 $END $REMARKS -HEADER EDITS: 2012/08/20 14:31:07 Applied edit header: C:\temp\Frank\1995-27\1995-27.txt -SORT parameters: 2012/08/20 14:32:40 Sorted in ascending order of channel Pressure -CLEAN functions: 2012/08/20 14:33:26 20 Reset #RECS, MIN & MAX values in header. Delete Empty Channels: 4 deleted. $END *INSTRUMENT TYPE : Bottle MODEL : Niskin 10 Litre *COMMENTS Collection method: ------------------ A rosette, holding 24 ten-litre water samplers, with a CTD was used. Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. Nutrient samples are analyzed fresh on board using a Technicon AAII auto- analyzer following methods described in Barwell-Clarke and Whitney (1996). !-1-- --2--- ---3--- --4--- !Samp Pressu Salinit Oxygen !le_ re y : !Numb Dissol !er ved !---- ------ ------- ------ *END OF HEADER 415 0.0 28.862 356.7 414 10.0 29.434 193.5 413 20.0 29.654 156.9 412 30.0 29.866 122.7 411 40.0 30.125 128.7 410 50.0 30.467 100.9 409 60.0 30.671 58.4 408 80.0 31.115 14.6 407 100.0 31.224 40.2 406 125.0 31.244 19.3 405 150.0 31.268 24.1 404 180.0 31.294 27.1