*2013/12/22 11:36:43.24 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 1995/09/25 16:42:00.000 NUMBER OF RECORDS : 12 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Down FILE TYPE : ASCII NUMBER OF CHANNELS : 4 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------------ --------- -------------- -------------- 1 Sample_Number n/a 356 367 2 Pressure decibar 0 160 3 Salinity PSS-78 28.8 31.302 4 Oxygen:Dissolved umol/kg 0 336 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' ' ' I5 I ' ' 2 -99 ' ' ' ' F7.1 R4 ' ' 3 -99 ' ' ' ' F8.3 R4 ' ' 4 -99 ' ' ' ' F7.1 R4 ' ' $END *ADMINISTRATION MISSION : 1995-27 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Saanich Inlet SCIENTIST : Stucchi D. PLATFORM : R.B. Young *LOCATION GEOGRAPHIC AREA : Saanich Inlet STATION : S1 EVENT NUMBER : 158 LATITUDE : 48 31.21000 N ! (deg min) LONGITUDE : 123 32.30000 W ! (deg min) *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SPRD2IS 4.9 2012/08/20 14:22:22 12 12 HDREDIT2 2.5.1 2012/08/20 14:31:07 ? ? SORT 3.5 2012/08/20 14:32:40 12 12 CLEAN 5.0.4 2012/08/20 14:33:27 12 12 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/22 11:36:43 12 12 $END $REMARKS -HEADER EDITS: 2012/08/20 14:31:07 Applied edit header: C:\temp\Frank\1995-27\1995-27.txt -SORT parameters: 2012/08/20 14:32:40 Sorted in ascending order of channel Pressure -CLEAN functions: 2012/08/20 14:33:26 20 Reset #RECS, MIN & MAX values in header. Delete Empty Channels: 4 deleted. $END *INSTRUMENT TYPE : Bottle MODEL : Niskin 10 Litre *COMMENTS Collection method: ------------------ A rosette, holding 24 ten-litre water samplers, with a CTD was used. Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. Nutrient samples are analyzed fresh on board using a Technicon AAII auto- analyzer following methods described in Barwell-Clarke and Whitney (1996). !-1-- --2--- ---3--- --4--- !Samp Pressu Salinit Oxygen !le_ re y : !Numb Dissol !er ved !---- ------ ------- ------ *END OF HEADER 367 0.0 28.800 336.0 366 10.0 29.358 172.2 365 20.0 29.494 109.9 364 30.0 29.677 84.4 363 40.0 29.895 65.2 362 50.0 30.311 31.5 361 60.0 30.615 10.6 360 80.0 31.099 0.0 359 100.0 31.158 0.0 358 120.0 31.190 0.0 357 140.0 31.240 0.0 356 160.0 31.302 15.2