*2013/12/22 11:36:43.07 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 1995/09/20 20:20:00.000 NUMBER OF RECORDS : 12 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Down FILE TYPE : ASCII NUMBER OF CHANNELS : 4 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------------ --------- -------------- -------------- 1 Sample_Number n/a 270 281 2 Pressure decibar 0 200 3 Salinity PSS-78 28.527 31.303 4 Oxygen:Dissolved umol/kg 11.2 364.6 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' ' ' I5 I ' ' 2 -99 ' ' ' ' F7.1 R4 ' ' 3 -99 ' ' ' ' F8.3 R4 ' ' 4 -99 ' ' ' ' F7.1 R4 ' ' $END *ADMINISTRATION MISSION : 1995-27 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Saanich Inlet SCIENTIST : Stucchi D. PLATFORM : R.B. Young *LOCATION GEOGRAPHIC AREA : Saanich Inlet STATION : S4 EVENT NUMBER : 104 LATITUDE : 48 37.31000 N ! (deg min) LONGITUDE : 123 29.94000 W ! (deg min) *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SPRD2IS 4.9 2012/08/20 14:22:22 12 12 HDREDIT2 2.5.1 2012/08/20 14:31:07 ? ? SORT 3.5 2012/08/20 14:32:40 12 12 CLEAN 5.0.4 2012/08/20 14:33:26 12 12 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/22 11:36:43 12 12 $END $REMARKS -HEADER EDITS: 2012/08/20 14:31:07 Applied edit header: C:\temp\Frank\1995-27\1995-27.txt -SORT parameters: 2012/08/20 14:32:40 Sorted in ascending order of channel Pressure -CLEAN functions: 2012/08/20 14:33:26 20 Reset #RECS, MIN & MAX values in header. Delete Empty Channels: 4 deleted. $END *INSTRUMENT TYPE : Bottle MODEL : Niskin 10 Litre *COMMENTS Collection method: ------------------ A rosette, holding 24 ten-litre water samplers, with a CTD was used. Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. Nutrient samples are analyzed fresh on board using a Technicon AAII auto- analyzer following methods described in Barwell-Clarke and Whitney (1996). !-1-- --2--- ---3--- --4--- !Samp Pressu Salinit Oxygen !le_ re y : !Numb Dissol !er ved !---- ------ ------- ------ *END OF HEADER 281 0.0 28.527 364.6 280 10.0 28.996 274.6 279 20.0 29.443 167.8 278 30.0 29.648 124.5 277 40.0 30.006 131.9 276 50.0 30.458 118.0 275 60.0 30.708 53.0 274 80.0 31.063 16.0 273 100.0 31.137 11.2 272 125.0 31.187 34.4 271 150.0 31.234 35.6 270 200.0 31.303 34.7