*2013/12/22 11:36:43.02 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 1995/09/20 18:01:00.000 NUMBER OF RECORDS : 8 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Down FILE TYPE : ASCII NUMBER OF CHANNELS : 4 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------------ --------- -------------- -------------- 1 Sample_Number n/a 242 249 2 Pressure decibar 0 91 3 Salinity PSS-78 28.775 32.389 4 Oxygen:Dissolved umol/kg 124.2 310.7 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' ' ' I5 I ' ' 2 -99 ' ' ' ' F7.1 R4 ' ' 3 -99 ' ' ' ' F8.3 R4 ' ' 4 -99 ' ' ' ' F7.1 R4 ' ' $END *ADMINISTRATION MISSION : 1995-27 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Saanich Inlet SCIENTIST : Stucchi D. PLATFORM : R.B. Young *LOCATION GEOGRAPHIC AREA : Saanich Inlet STATION : S8 EVENT NUMBER : 98 LATITUDE : 48 43.28000 N ! (deg min) LONGITUDE : 123 25.25000 W ! (deg min) *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SPRD2IS 4.9 2012/08/20 14:22:22 8 8 HDREDIT2 2.5.1 2012/08/20 14:31:07 ? ? SORT 3.5 2012/08/20 14:32:40 8 8 CLEAN 5.0.4 2012/08/20 14:33:26 8 8 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/22 11:36:43 8 8 $END $REMARKS -HEADER EDITS: 2012/08/20 14:31:07 Applied edit header: C:\temp\Frank\1995-27\1995-27.txt -SORT parameters: 2012/08/20 14:32:40 Sorted in ascending order of channel Pressure -CLEAN functions: 2012/08/20 14:33:26 20 Reset #RECS, MIN & MAX values in header. Delete Empty Channels: 4 deleted. $END *COMMENTS Sample_Number 242: misfire somewhere - check against CTD cast Collection method: ------------------ A rosette, holding 24 ten-litre water samplers, with a CTD was used. Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. Nutrient samples are analyzed fresh on board using a Technicon AAII auto- analyzer following methods described in Barwell-Clarke and Whitney (1996). *INSTRUMENT TYPE : Bottle MODEL : Niskin 10 Litre !-1-- --2--- ---3--- --4--- !Samp Pressu Salinit Oxygen !le_ re y : !Numb Dissol !er ved !---- ------ ------- ------ *END OF HEADER 249 0.0 28.775 310.7 248 20.0 29.346 240.8 247 30.0 29.781 185.9 246 40.0 29.962 176.4 245 50.0 30.357 159.7 244 60.0 30.601 156.5 243 80.0 32.037 -99.0 242 91.0 32.389 124.2