*2013/12/22 11:36:42.88 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 1995/09/18 20:59:00.000 NUMBER OF RECORDS : 12 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Down FILE TYPE : ASCII NUMBER OF CHANNELS : 4 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------------ --------- -------------- -------------- 1 Sample_Number n/a 182 193 2 Pressure decibar 0 200 3 Salinity PSS-78 28.693 31.24 4 Oxygen:Dissolved umol/kg 0 360 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' ' ' I5 I ' ' 2 -99 ' ' ' ' F7.1 R4 ' ' 3 -99 ' ' ' ' F8.3 R4 ' ' 4 -99 ' ' ' ' F7.1 R4 ' ' $END *ADMINISTRATION MISSION : 1995-27 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Saanich Inlet SCIENTIST : Stucchi D. PLATFORM : R.B. Young *LOCATION GEOGRAPHIC AREA : Saanich Inlet STATION : S4 EVENT NUMBER : 88 LATITUDE : 48 37.35000 N ! (deg min) LONGITUDE : 123 29.89000 W ! (deg min) *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SPRD2IS 4.9 2012/08/20 14:22:22 12 12 HDREDIT2 2.5.1 2012/08/20 14:31:07 ? ? SORT 3.5 2012/08/20 14:32:40 12 12 CLEAN 5.0.4 2012/08/20 14:33:26 12 12 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/22 11:36:42 12 12 $END $REMARKS -HEADER EDITS: 2012/08/20 14:31:07 Applied edit header: C:\temp\Frank\1995-27\1995-27.txt -SORT parameters: 2012/08/20 14:32:40 Sorted in ascending order of channel Pressure -CLEAN functions: 2012/08/20 14:33:26 20 Reset #RECS, MIN & MAX values in header. Delete Empty Channels: 4 deleted. $END *INSTRUMENT TYPE : Bottle MODEL : Niskin 10 Litre *COMMENTS Collection method: ------------------ A rosette, holding 24 ten-litre water samplers, with a CTD was used. Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. Nutrient samples are analyzed fresh on board using a Technicon AAII auto- analyzer following methods described in Barwell-Clarke and Whitney (1996). !-1-- --2--- ---3--- --4--- !Samp Pressu Salinit Oxygen !le_ re y : !Numb Dissol !er ved !---- ------ ------- ------ *END OF HEADER 193 0.0 28.693 360.0 192 10.0 29.127 253.2 191 20.0 29.430 165.5 190 30.0 29.688 119.4 189 40.0 29.975 124.7 188 50.0 30.221 122.1 187 60.0 30.539 90.7 186 80.0 30.990 39.5 185 100.0 31.130 22.0 184 125.0 31.183 40.0 183 150.0 31.202 16.9 182 200.0 31.240 0.0