*2013/12/16 15:08:20.54 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 1995/07/23 04:53:10.160 END TIME : UTC 1995/07/23 05:38:28.980 NUMBER OF RECORDS : 3 DATA DESCRIPTION : Bottle:Rosette FILE TYPE : ASCII DATA TYPE : real*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ----------------- --------- -------------- -------------- 1 Sample_Number n/a 1 3 2 Pressure decibar 1743.5 1874.4 3 Salinity:Bottle PSS-78 34.5564 34.5667 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 10 F ' ' 4 $END *ADMINISTRATION MISSION : 1995-21 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Endeavour Ridge SCIENTIST : Thomson R.E. PLATFORM : Endeavour *LOCATION GEOGRAPHIC AREA : Endeavour Ridge STATION : R9509 EVENT NUMBER : 65 LATITUDE : 47 55.78000 N ! (deg min) LONGITUDE : 129 5.75000 W ! (deg min) WATER DEPTH : 2375 *INSTRUMENT TYPE : Bottle MODEL : Niskin (10 litre) $REMARKS Salinity analyzed using a Guildline Portsal Salinometer model 8410, serial number 59724. Instrument standardized against IAPSO Standard Seawater from Wormely, England. $END *COMMENTS Analyzes methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC900 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- HDREDIT2 1.6 2003/09/09 11:13:46 ? ? CLEAN 4.4 2003/09/09 11:14:09 3 3 SORT 3.4.1 2004/04/13 14:12:00 3 3 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:08:20 3 3 $END $REMARKS CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel $END !-1-- --2--- ----3---- !Samp Pressu Salinity: !le_ re Bottle !Numb !er !---- ------ --------- *END OF HEADER 1 1743.5 34.5564 2 1825.8 34.5575 3 1874.4 34.5667