*2013/12/22 11:36:36.81 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 1995/07/20 23:12:00.000 NUMBER OF RECORDS : 12 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Down FILE TYPE : ASCII NUMBER OF CHANNELS : 4 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------------ --------- -------------- -------------- 1 Sample_Number n/a 614 625 2 Pressure decibar 0 171.5 3 Salinity PSS-78 28.871 31.231 4 Oxygen:Dissolved umol/kg 0.1 410.2 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' ' ' I5 I ' ' 2 -99 ' ' ' ' F7.1 R4 ' ' 3 -99 ' ' ' ' F8.3 R4 ' ' 4 -99 ' ' ' ' F7.1 R4 ' ' $END *ADMINISTRATION MISSION : 1995-20 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Saanich Inlet SCIENTIST : Stucchi D. PLATFORM : Vector *LOCATION GEOGRAPHIC AREA : Saanich Inlet STATION : S1 EVENT NUMBER : 141 LATITUDE : 48 31.13000 N ! (deg min) LONGITUDE : 123 32.37000 W ! (deg min) *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SPRD2IS 4.9 2012/08/20 10:06:47 12 12 HDREDIT2 2.5.1 2012/08/20 10:07:26 ? ? CLEAN 5.0.4 2012/08/20 10:10:49 12 12 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/22 11:36:36 12 12 $END $REMARKS -HEADER EDITS: 2012/08/20 10:07:26 Applied edit header: C:\temp\Frank\1995-20.txt -CLEAN functions: 2012/08/20 10:10:48 20 Reset #RECS, MIN & MAX values in header. Delete Empty Channels: 10 deleted. $END *INSTRUMENT TYPE : Bottle MODEL : Niskin 10 Litre *COMMENTS Collection method: ------------------ A rosette, holding 24 ten-litre water samplers, with a CTD was used. Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. Nutrient samples are analyzed fresh on board using a Technicon AAII auto- analyzer following methods described in Barwell-Clarke and Whitney (1996). For more information on methods see Gargett et al. Estuarine, Coastal and Shelf Science 56 (2003) 1141–1156. !-1-- --2--- ---3--- --4--- !Samp Pressu Salinit Oxygen !le_ re y : !Numb Dissol !er ved !---- ------ ------- ------ *END OF HEADER 625 0.0 28.871 410.2 624 10.5 28.946 332.6 623 19.9 29.143 185.4 622 29.9 29.366 157.5 621 40.2 29.527 131.5 620 50.1 29.707 82.2 619 60.3 30.127 76.8 618 80.1 30.726 13.1 617 99.9 30.893 5.1 616 119.9 31.073 0.1 615 140.0 31.197 0.1 614 171.5 31.231 0.1