*2013/12/22 11:36:36.70 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 1995/07/20 17:05:00.000 NUMBER OF RECORDS : 12 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Down FILE TYPE : ASCII NUMBER OF CHANNELS : 4 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------------ --------- -------------- -------------- 1 Sample_Number n/a 535 546 2 Pressure decibar 0 161 3 Salinity PSS-78 27.084 32.136 4 Oxygen:Dissolved umol/kg 155.8 262.2 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' ' ' I5 I ' ' 2 -99 ' ' ' ' F7.1 R4 ' ' 3 -99 ' ' ' ' F8.3 R4 ' ' 4 -99 ' ' ' ' F7.1 R4 ' ' $END *ADMINISTRATION MISSION : 1995-20 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Saanich Inlet SCIENTIST : Stucchi D. PLATFORM : Vector *LOCATION GEOGRAPHIC AREA : Saanich Inlet STATION : S9 EVENT NUMBER : 127 LATITUDE : 48 43.51000 N ! (deg min) LONGITUDE : 123 15.71000 W ! (deg min) *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SPRD2IS 4.9 2012/08/20 10:06:47 12 12 HDREDIT2 2.5.1 2012/08/20 10:07:26 ? ? CLEAN 5.0.4 2012/08/20 10:10:49 12 12 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/22 11:36:36 12 12 $END $REMARKS -HEADER EDITS: 2012/08/20 10:07:26 Applied edit header: C:\temp\Frank\1995-20.txt -CLEAN functions: 2012/08/20 10:10:48 20 Reset #RECS, MIN & MAX values in header. Delete Empty Channels: 10 deleted. $END *INSTRUMENT TYPE : Bottle MODEL : Niskin 10 Litre *COMMENTS Collection method: ------------------ A rosette, holding 24 ten-litre water samplers, with a CTD was used. Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. Nutrient samples are analyzed fresh on board using a Technicon AAII auto- analyzer following methods described in Barwell-Clarke and Whitney (1996). For more information on methods see Gargett et al. Estuarine, Coastal and Shelf Science 56 (2003) 1141–1156. !-1-- --2--- ---3--- --4--- !Samp Pressu Salinit Oxygen !le_ re y : !Numb Dissol !er ved !---- ------ ------- ------ *END OF HEADER 546 0.0 27.084 262.2 545 9.6 27.935 235.3 544 19.9 29.552 202.6 543 30.1 29.890 195.9 542 40.1 30.008 193.4 541 49.9 30.394 185.8 540 60.3 30.582 183.5 539 80.2 30.801 183.7 538 100.0 31.783 161.8 537 125.4 31.967 158.7 536 150.2 32.010 155.8 535 161.0 32.136 216.8