*2013/12/22 11:36:36.44 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 1995/07/13 22:46:00.000 NUMBER OF RECORDS : 12 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Down FILE TYPE : ASCII NUMBER OF CHANNELS : 4 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------------ --------- -------------- -------------- 1 Sample_Number n/a 314 325 2 Pressure decibar 0 200 3 Salinity PSS-78 28.906 31.256 4 Oxygen:Dissolved umol/kg 0.1 337.4 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' ' ' I5 I ' ' 2 -99 ' ' ' ' F7.1 R4 ' ' 3 -99 ' ' ' ' F8.3 R4 ' ' 4 -99 ' ' ' ' F7.1 R4 ' ' $END *ADMINISTRATION MISSION : 1995-20 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Saanich Inlet SCIENTIST : Stucchi D. PLATFORM : Vector *LOCATION GEOGRAPHIC AREA : Saanich Inlet STATION : S2 EVENT NUMBER : 69 LATITUDE : 48 33.49000 N ! (deg min) LONGITUDE : 123 30.33000 W ! (deg min) *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- SPRD2IS 4.9 2012/08/20 10:06:46 12 12 HDREDIT2 2.5.1 2012/08/20 10:07:26 ? ? CLEAN 5.0.4 2012/08/20 10:10:49 12 12 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/22 11:36:36 12 12 $END $REMARKS -HEADER EDITS: 2012/08/20 10:07:26 Applied edit header: C:\temp\Frank\1995-20.txt -CLEAN functions: 2012/08/20 10:10:48 20 Reset #RECS, MIN & MAX values in header. Delete Empty Channels: 10 deleted. $END *INSTRUMENT TYPE : Bottle MODEL : Niskin 10 Litre *COMMENTS Collection method: ------------------ A rosette, holding 24 ten-litre water samplers, with a CTD was used. Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. Nutrient samples are analyzed fresh on board using a Technicon AAII auto- analyzer following methods described in Barwell-Clarke and Whitney (1996). For more information on methods see Gargett et al. Estuarine, Coastal and Shelf Science 56 (2003) 1141–1156. !-1-- --2--- ---3--- --4--- !Samp Pressu Salinit Oxygen !le_ re y : !Numb Dissol !er ved !---- ------ ------- ------ *END OF HEADER 325 0.0 28.906 337.4 324 9.6 29.237 190.5 323 20.0 29.391 174.1 322 29.8 29.489 167.6 321 39.2 29.641 160.8 320 50.0 30.059 148.4 319 60.0 30.353 147.8 318 80.0 30.841 82.4 317 100.0 30.945 31.3 316 125.0 31.142 0.2 315 150.0 31.229 0.2 314 200.0 31.256 0.1