*2013/12/16 15:07:27.57 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 1995/05/15 22:12:00.000 NUMBER OF RECORDS : 23 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII NUMBER OF CHANNELS : 16 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ---------------------------- ---------------- -------------- -------------- 1 Sample_Number n/a 102 124 2 Pressure decibar 10.7 3819.2 3 Oxygen:Dissolved mL/L 0.371 7.189 4 Oxygen:Dissolved umol/kg 16.1 313 5 Salinity:Bottle PSS-78 32.6864 34.676 6 Bottle_Number n/a 1 23 7 Temperature 'deg C (IPTS68)' 1.5281 7.8056 8 Nitrate_plus_Nitrite umol/L 10.1 46 9 Phosphate umol/L 1.07 3.23 10 Silicate umol/L 13.9 172.7 11 Carbon:Dissolved:Organic umol/L 67.29 76.47 12 Nitrogen:Dissolved:Organic umol/L 2.82 5.33 13 Chlorofluorocarbon_11 pmol/kg 0 4.841 14 Flag:Chlorofluorocarbon_11 n/a 15 Chlorofluorocarbon_12 pmol/kg 0 2.594 16 Flag:Chlorofluorocarbon_12 n/a $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 8 F ' ' 3 4 -99 ' ' 6 F ' ' 1 5 -99 ' ' 9 F ' ' 4 6 -99 ' ' 3 I I 0 7 -99 ' ' 9 F ' ' 4 8 -99 ' ' 6 F R4 1 9 -99 ' ' 7 F R4 2 10 -99 ' ' 6 F R4 1 11 -99 ' ' ' ' F7.2 R4 ' ' 12 -99 ' ' ' ' F7.2 R4 ' ' 13 -99 ' ' ' ' F8.3 R4 ' ' 14 0 ' ' 2 NQ C ' ' 15 -99 ' ' ' ' F8.3 R4 ' ' 16 0 ' ' 2 NQ C ' ' $END $REMARKS Data quality is expressed with the following flags ------------------------------------------------------------------------------ 1 = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). 2 = Acceptable measurement (not normally used). 3 = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). 4 = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). 5 = Not reported (lost sample; unredeemably bad measurement). 6 = Mean of replicate measurements. 7 = Manual chromatographic peak measurement. 8 = Irregular digital chromatographic peak integration. 9 = Sample not drawn for this measurement from this bottle (not normally used). ------------------------------------------------------------------------------ $END *ADMINISTRATION MISSION : 1995-05 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Line P, WOCE, JGOFS SCIENTIST : Whitney F. PLATFORM : John P. Tully *LOCATION STATION : MP23 EVENT NUMBER : 47 LATITUDE : 49 46.13000 N ! (deg min) LONGITUDE : 141 40.21000 W ! (deg min) WATER DEPTH : 4057 *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- REMOVECH 3.2 2000/02/23 16:16:40 23 23 HDREDIT2 1.2 2001/12/31 13:46:44 ? ? REMOVECH 6.0 2001/12/31 13:50:39 23 23 REMOVECH 6.0 2003/05/09 16:30:26 23 23 MERGE 2.8 2003/05/20 11:15:35 23 23 HDREDIT2 1.6 2003/05/20 11:22:58 ? ? CLEAN 4.2 2003/05/20 11:23:42 23 23 SORT 3.4.1 2004/04/13 14:06:52 23 23 MERGE 3.4 2012/07/18 14:02:00 23 23 SORT 3.5 2012/11/29 15:46:54 23 23 MERGE 3.4 2012/11/29 15:47:51 23 23 SORT 3.5 2012/11/29 15:59:00 23 23 HDREDIT2 2.5.1 2012/11/29 16:01:07 ? ? CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:07:27 23 23 $END $REMARKS -The following CHANNEL(S) were removed from file. Temperature:Sample -The following CHANNEL(S) were removed from file. Flask_Number -The following CHANNEL(S) were removed from file. Silicate Nitrate_plus_nitrite Phosphate -The following MERGE parameters were used: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Nitrate_plus_Nitrite, Phosphate, Silicate Primary file : H:\STNPCHEM\process\1995\1995-05\bottle\95050047.rem Secondary file: H:\STNPCHEM\process\1995\1995-05\bottle\95050047.rev CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel -The following MERGE parameters were used: 2012/07/18 14:02:00 2012/07/18 14:02:00 2012/07/18 14:02: Merge Channel: Pressure Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Secondary Primary Channels to Include: ALL Secondary Channels to Include: Carbon:Dissolved:Organic, Nitrogen:Dissolved:Organic Primary file : P:\John Pages Archive\1995-05\DOC&DON\1995-05-0047.che Secondary file: P:\John Pages Archive\1995-05\DOC&DON\1995-05-0047.ios -SORT parameters: 2012/11/29 15:46:54 Sorted in ascending order of channel Sample_Number -The following MERGE parameters were used: 2012/11/29 15:47:50 2012/11/29 15:47:51 2012/11/29 15:47: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Secondary Primary Channels to Include: ALL Secondary Channels to Include: Chlorofluorocarbon_11, Flag:Chlorofluorocarbon_11, Chlorofluorocarbon_12, Flag:Chlorofluorocarbon_12 Primary file : P:\John Pages Archive\1995-05\CFC\1995-05-0047.srt Secondary file: P:\John Pages Archive\1995-05\CFC\1995-05-0047.ios -SORT parameters: 2012/11/29 15:59:00 Sorted in ascending order of channel Pressure -HEADER EDITS: 2012/11/29 16:01:07 Applied edit header: O:\Data Processing\Header Comments\Work\Freons_with_flags.txt $END *INSTRUMENT TYPE : Bottle MODEL : Niskin 10 Litre *COMMENTS Collection method: ------------------ A rosette, holding 24 ten-litre water samplers, with a CTD was used. Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. Nutrient samples are analyzed fresh on board using a Technicon AAII auto- analyzer following methods described in Barwell-Clarke and Whitney (1996). Chlorophyll was extracted with 90% acetone and analyzed fluorimetrically. CFC-11 and CFC-12, in their current form, do not meet the relaxed WOCE standard for CFC's. Therefore the CFC qulaity flags have been given a value of'3'(questionable). For CFC methods refer to the "Centre for Ocean Climate Chemistry Freon Data Report" located in the cruise .DOC directory. . References: 1. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 2. J. Barwell-Clarke and F. Whitney. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. 3. Minkley, B.G., and F.A. Whitney. 2001. Summary of Hydrographic/CTD Observations Made Along Line P and at Station P: 1991-1999. Canadian Data Report of Hydrography and Ocean Sciences 156: 45 pp. !-1-- --2--- ---3--- --4-- ---5---- 6- ---7---- --8-- --9--- --10- --11-- --12-- ---13-- - ---15-- - !Samp Pressu Oxygen: Oxyge Salinity Bo Temperat Nitra Phosph Silic Carbon Nitrog Chlorof F Chlorof F !le_ re Dissolv n: :Bottle tt ure te_ ate ate : en: luoroca l luoroca l !Numb ed Disso ~u plus_ Dissol Dissol rbon_11 ~ rbon_12 ~ !er lved mb Nitri ved:Or ved:Or 1 1 ! er te ganic ganic 1 2 !---- ------ ------- ----- -------- -- -------- ----- ------ ----- ------ ------ ------- - ------- - *END OF HEADER 124 10.7 7.085 308.5 32.6864 23 7.8056 10.1 1.07 13.9 76.47 5.33 4.433 3 2.271 3 123 25.4 7.144 311.1 32.6877 22 7.4825 10.1 1.07 14.1 71.01 4.26 4.767 3 2.393 3 122 49.4 7.189 313.0 32.6934 21 6.5783 10.6 1.10 14.5 68.14 2.82 4.441 3 2.504 3 121 75.2 7.020 305.7 32.7017 20 6.2487 11.4 1.17 15.4 -99.00 -99.00 4.801 3 2.373 3 120 99.9 7.051 307.0 32.7272 19 5.9407 12.8 1.25 17.0 70.23 5.15 4.841 3 2.594 3 119 150.1 4.432 192.8 33.7722 18 6.2484 26.5 1.91 39.8 -99.00 -99.00 3.350 3 1.809 3 118 198.9 3.685 160.3 33.8412 17 5.5858 30.9 2.20 51.6 67.29 4.57 -99.000 9 -99.000 9 117 297.5 2.647 115.1 33.8616 16 4.5295 37.1 2.61 69.9 -99.00 -99.00 2.732 3 1.294 3 115 399.8 1.699 73.9 33.9420 14 4.1324 41.0 2.87 85.7 -99.00 -99.00 1.489 3 0.902 3 116 399.8 1.738 75.6 33.9415 15 4.1329 41.3 2.88 85.3 67.57 -99.00 1.319 3 0.824 3 114 598.2 0.642 27.9 34.1580 13 3.7185 44.7 3.13 113.4 -99.00 -99.00 0.278 3 0.351 3 113 806.6 0.489 21.2 34.2800 12 3.3334 45.2 3.19 129.5 -99.00 -99.00 0.000 3 0.000 3 112 982.9 0.399 17.3 34.3536 11 3.0260 45.6 3.22 141.1 -99.00 -99.00 0.000 3 0.000 3 111 1249.5 0.371 16.1 34.4360 10 2.6572 46.0 3.23 154.3 -99.00 -99.00 -99.000 9 -99.000 9 110 1502.3 0.553 24.0 34.4960 9 2.3690 45.8 3.19 162.8 -99.00 -99.00 -99.000 9 -99.000 9 109 1748.1 0.857 37.2 34.5404 8 2.1634 45.1 3.12 167.5 -99.00 -99.00 -99.000 9 -99.000 9 108 2001.0 1.267 55.1 34.5805 7 1.9660 43.8 3.05 170.3 -99.00 -99.00 -99.000 9 -99.000 9 107 2249.4 1.615 70.2 34.6067 6 1.8347 43.1 2.98 172.1 -99.00 -99.00 -99.000 9 -99.000 9 106 2500.9 1.952 84.8 34.6268 5 1.7299 42.1 2.91 172.7 -99.00 -99.00 -99.000 9 -99.000 9 105 2751.1 2.271 98.7 34.6440 4 1.6417 41.2 2.84 171.7 -99.00 -99.00 -99.000 9 -99.000 9 104 3007.4 2.483 107.9 34.6536 3 1.5999 40.5 2.81 171.1 -99.00 -99.00 -99.000 9 -99.000 9 103 3497.1 2.897 125.9 34.6700 2 1.5358 39.7 2.76 169.2 -99.00 -99.00 -99.000 9 -99.000 9 102 3819.2 3.029 131.6 34.6760 1 1.5281 39.2 2.70 169.6 -99.00 -99.00 -99.000 9 -99.000 9