*2013/12/16 15:07:27.54 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 1995/05/15 03:28:00.000 NUMBER OF RECORDS : 23 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII NUMBER OF CHANNELS : 16 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ---------------------------- ---------------- -------------- -------------- 1 Sample_Number n/a 79 101 2 Pressure decibar 11.1 4013.1 3 Oxygen:Dissolved mL/L 0.378 7.159 4 Oxygen:Dissolved umol/kg 16.4 311.8 5 Salinity:Bottle PSS-78 32.6365 34.6778 6 Bottle_Number n/a 1 23 7 Temperature 'deg C (IPTS68)' 1.537 8.2249 8 Nitrate_plus_Nitrite umol/L 7.9 45.7 9 Phosphate umol/L 0.96 3.23 10 Silicate umol/L 12.7 174.4 11 Carbon:Dissolved:Organic umol/L 65.72 84.65 12 Nitrogen:Dissolved:Organic umol/L 2.63 5.97 13 Chlorofluorocarbon_11 pmol/kg 0 4.893 14 Flag:Chlorofluorocarbon_11 n/a 15 Chlorofluorocarbon_12 pmol/kg 0 2.487 16 Flag:Chlorofluorocarbon_12 n/a $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 8 F ' ' 3 4 -99 ' ' 6 F ' ' 1 5 -99 ' ' 9 F ' ' 4 6 -99 ' ' 3 I I 0 7 -99 ' ' 9 F ' ' 4 8 -99 ' ' 6 F R4 1 9 -99 ' ' 7 F R4 2 10 -99 ' ' 6 F R4 1 11 -99 ' ' ' ' F7.2 R4 ' ' 12 -99 ' ' ' ' F7.2 R4 ' ' 13 -99 ' ' ' ' F8.3 R4 ' ' 14 0 ' ' 2 NQ C ' ' 15 -99 ' ' ' ' F8.3 R4 ' ' 16 0 ' ' 2 NQ C ' ' $END $REMARKS Data quality is expressed with the following flags ------------------------------------------------------------------------------ 1 = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). 2 = Acceptable measurement (not normally used). 3 = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). 4 = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). 5 = Not reported (lost sample; unredeemably bad measurement). 6 = Mean of replicate measurements. 7 = Manual chromatographic peak measurement. 8 = Irregular digital chromatographic peak integration. 9 = Sample not drawn for this measurement from this bottle (not normally used). ------------------------------------------------------------------------------ $END *ADMINISTRATION MISSION : 1995-05 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Line P, WOCE, JGOFS SCIENTIST : Whitney F. PLATFORM : John P. Tully *LOCATION STATION : MP20 EVENT NUMBER : 41 LATITUDE : 49 34.07000 N ! (deg min) LONGITUDE : 138 40.37000 W ! (deg min) WATER DEPTH : 3953 *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- REMOVECH 3.2 2000/02/23 16:16:40 23 23 HDREDIT2 1.2 2001/12/31 13:46:44 ? ? REMOVECH 6.0 2001/12/31 13:50:39 23 23 REMOVECH 6.0 2003/05/09 16:30:26 23 23 MERGE 2.8 2003/05/20 11:15:35 23 23 HDREDIT2 1.6 2003/05/20 11:22:58 ? ? CLEAN 4.2 2003/05/20 11:23:42 23 23 SORT 3.4.1 2004/04/13 14:06:49 23 23 MERGE 3.4 2012/07/18 14:02:00 23 23 SORT 3.5 2012/11/29 15:46:54 23 23 MERGE 3.4 2012/11/29 15:47:51 23 23 SORT 3.5 2012/11/29 15:59:00 23 23 HDREDIT2 2.5.1 2012/11/29 16:01:06 ? ? CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:07:27 23 23 $END $REMARKS -The following CHANNEL(S) were removed from file. Temperature:Sample -The following CHANNEL(S) were removed from file. Flask_Number -The following CHANNEL(S) were removed from file. Silicate Nitrate_plus_nitrite Phosphate -The following MERGE parameters were used: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Nitrate_plus_Nitrite, Phosphate, Silicate Primary file : H:\STNPCHEM\process\1995\1995-05\bottle\95050041.rem Secondary file: H:\STNPCHEM\process\1995\1995-05\bottle\95050041.rev CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel -The following MERGE parameters were used: 2012/07/18 14:02:00 2012/07/18 14:02:00 2012/07/18 14:02: Merge Channel: Pressure Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Secondary Primary Channels to Include: ALL Secondary Channels to Include: Carbon:Dissolved:Organic, Nitrogen:Dissolved:Organic Primary file : P:\John Pages Archive\1995-05\DOC&DON\1995-05-0041.che Secondary file: P:\John Pages Archive\1995-05\DOC&DON\1995-05-0041.ios -SORT parameters: 2012/11/29 15:46:54 Sorted in ascending order of channel Sample_Number -The following MERGE parameters were used: 2012/11/29 15:47:50 2012/11/29 15:47:51 2012/11/29 15:47: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Secondary Primary Channels to Include: ALL Secondary Channels to Include: Chlorofluorocarbon_11, Flag:Chlorofluorocarbon_11, Chlorofluorocarbon_12, Flag:Chlorofluorocarbon_12 Primary file : P:\John Pages Archive\1995-05\CFC\1995-05-0041.srt Secondary file: P:\John Pages Archive\1995-05\CFC\1995-05-0041.ios -SORT parameters: 2012/11/29 15:59:00 Sorted in ascending order of channel Pressure -HEADER EDITS: 2012/11/29 16:01:06 Applied edit header: O:\Data Processing\Header Comments\Work\Freons_with_flags.txt $END *INSTRUMENT TYPE : Bottle MODEL : Niskin 10 Litre *COMMENTS Collection method: ------------------ A rosette, holding 24 ten-litre water samplers, with a CTD was used. Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. Nutrient samples are analyzed fresh on board using a Technicon AAII auto- analyzer following methods described in Barwell-Clarke and Whitney (1996). Chlorophyll was extracted with 90% acetone and analyzed fluorimetrically. CFC-11 and CFC-12, in their current form, do not meet the relaxed WOCE standard for CFC's. Therefore the CFC qulaity flags have been given a value of'3'(questionable). For CFC methods refer to the "Centre for Ocean Climate Chemistry Freon Data Report" located in the cruise .DOC directory. . References: 1. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 2. J. Barwell-Clarke and F. Whitney. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. 3. Minkley, B.G., and F.A. Whitney. 2001. Summary of Hydrographic/CTD Observations Made Along Line P and at Station P: 1991-1999. Canadian Data Report of Hydrography and Ocean Sciences 156: 45 pp. !-1-- --2--- ---3--- --4-- ---5---- 6- ---7---- --8-- --9--- --10- --11-- --12-- ---13-- - ---15-- - !Samp Pressu Oxygen: Oxyge Salinity Bo Temperat Nitra Phosph Silic Carbon Nitrog Chlorof F Chlorof F !le_ re Dissolv n: :Bottle tt ure te_ ate ate : en: luoroca l luoroca l !Numb ed Disso ~u plus_ Dissol Dissol rbon_11 ~ rbon_12 ~ !er lved mb Nitri ved:Or ved:Or 1 1 ! er te ganic ganic 1 2 !---- ------ ------- ----- -------- -- -------- ----- ------ ----- ------ ------ ------- - ------- - *END OF HEADER 100 11.1 7.049 307.0 32.6512 22 8.2041 8.4 0.98 13.4 84.65 5.97 4.495 3 2.326 3 101 11.2 7.054 307.2 32.6566 23 8.2249 8.6 0.99 13.6 -99.00 -99.00 4.452 3 2.273 3 99 25.1 7.089 308.8 32.6365 21 7.8022 7.9 0.96 12.7 84.03 5.74 4.506 3 2.296 3 98 48.7 7.159 311.8 32.6933 20 7.0641 9.4 1.04 15.0 81.62 5.67 4.893 3 2.487 3 97 74.7 7.064 307.6 32.7093 19 6.2632 11.3 1.17 16.4 -99.00 -99.00 4.857 3 2.420 3 96 100.3 6.757 294.0 32.8099 18 6.0345 13.5 1.30 18.9 76.63 5.55 4.715 3 2.447 3 95 151.8 4.174 181.6 33.7600 17 6.4238 26.8 1.97 40.8 -99.00 -99.00 3.487 3 1.896 3 94 200.3 3.626 157.8 33.8422 16 5.8072 31.0 2.23 51.7 75.68 5.47 2.755 3 1.510 3 93 300.3 2.402 104.5 33.8652 15 4.6166 37.2 2.66 71.0 -99.00 -99.00 1.969 3 1.267 3 92 400.6 1.468 63.9 33.9530 14 4.2628 41.4 2.93 87.1 65.72 2.63 1.180 3 0.737 3 91 599.9 0.591 25.7 34.1512 13 3.8292 44.2 3.17 112.5 -99.00 -99.00 0.141 3 0.400 3 90 802.2 0.482 21.0 34.2704 12 3.3768 44.9 3.20 130.0 -99.00 -99.00 0.000 3 0.000 3 89 1002.9 0.386 16.8 34.3617 11 2.9918 45.4 3.23 144.0 -99.00 -99.00 0.000 3 0.000 3 88 1250.4 0.378 16.4 34.4360 10 2.6587 45.7 3.23 155.2 -99.00 -99.00 -99.000 9 -99.000 9 87 1500.9 0.578 25.1 34.4910 9 2.3851 45.3 3.19 163.9 -99.00 -99.00 -99.000 9 -99.000 9 86 1747.8 0.933 40.5 34.5482 8 2.1157 44.6 3.12 169.7 -99.00 -99.00 -99.000 9 -99.000 9 85 2000.0 1.280 55.6 34.5820 7 1.9548 43.7 3.05 172.5 -99.00 -99.00 -99.000 9 -99.000 9 84 2250.2 1.609 69.9 34.6104 6 1.8274 42.9 2.98 173.8 -99.00 -99.00 -99.000 9 -99.000 9 83 2500.2 1.965 85.4 34.6287 5 1.7221 42.0 2.91 173.6 -99.00 -99.00 -99.000 9 -99.000 9 82 2749.8 2.284 99.3 34.6438 4 1.6431 41.3 2.85 172.8 -99.00 -99.00 -99.000 9 -99.000 9 81 2999.3 2.508 109.0 34.6548 3 1.5912 40.7 2.80 172.6 -99.00 -99.00 -99.000 9 -99.000 9 80 3501.5 2.884 125.3 34.6696 2 1.5370 39.7 2.72 171.6 -99.00 -99.00 -99.000 9 -99.000 9 79 4013.1 3.042 132.2 34.6778 1 1.5438 39.3 2.69 174.4 -99.00 -99.00 -99.000 9 -99.000 9