*2013/12/16 15:07:27.51 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 1995/05/14 04:38:00.000 NUMBER OF RECORDS : 23 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII NUMBER OF CHANNELS : 16 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ---------------------------- ---------------- -------------- -------------- 1 Sample_Number n/a 56 78 2 Pressure decibar 10.1 3679.2 3 Oxygen:Dissolved mL/L 0.342 7.052 4 Oxygen:Dissolved umol/kg 14.9 307.1 5 Salinity:Bottle PSS-78 32.4774 34.6704 6 Bottle_Number n/a 1 23 7 Temperature 'deg C (IPTS68)' 1.5754 8.6404 8 Nitrate_plus_Nitrite umol/L 7.2 45.6 9 Phosphate umol/L 0.92 3.23 10 Silicate umol/L 12.3 175 11 Carbon:Dissolved:Organic umol/L 70.41 84.94 12 Nitrogen:Dissolved:Organic umol/L 5.11 7.03 13 Chlorofluorocarbon_11 pmol/kg 0 4.656 14 Flag:Chlorofluorocarbon_11 n/a 15 Chlorofluorocarbon_12 pmol/kg 0 3.63 16 Flag:Chlorofluorocarbon_12 n/a $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 8 F ' ' 3 4 -99 ' ' 6 F ' ' 1 5 -99 ' ' 9 F ' ' 4 6 -99 ' ' 3 I I 0 7 -99 ' ' 9 F ' ' 4 8 -99 ' ' 6 F R4 1 9 -99 ' ' 7 F R4 2 10 -99 ' ' 6 F R4 1 11 -99 ' ' ' ' F7.2 R4 ' ' 12 -99 ' ' ' ' F7.2 R4 ' ' 13 -99 ' ' ' ' F8.3 R4 ' ' 14 0 ' ' 2 NQ C ' ' 15 -99 ' ' ' ' F8.3 R4 ' ' 16 0 ' ' 2 NQ C ' ' $END $REMARKS Data quality is expressed with the following flags ------------------------------------------------------------------------------ 1 = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). 2 = Acceptable measurement (not normally used). 3 = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). 4 = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). 5 = Not reported (lost sample; unredeemably bad measurement). 6 = Mean of replicate measurements. 7 = Manual chromatographic peak measurement. 8 = Irregular digital chromatographic peak integration. 9 = Sample not drawn for this measurement from this bottle (not normally used). ------------------------------------------------------------------------------ $END *ADMINISTRATION MISSION : 1995-05 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Line P, WOCE, JGOFS SCIENTIST : Whitney F. PLATFORM : John P. Tully *LOCATION STATION : MP16 EVENT NUMBER : 33 LATITUDE : 49 16.72000 N ! (deg min) LONGITUDE : 134 40.71000 W ! (deg min) WATER DEPTH : 3632 *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- REMOVECH 3.2 2000/02/23 16:16:40 23 23 HDREDIT2 1.2 2001/12/31 13:46:44 ? ? REMOVECH 6.0 2001/12/31 13:50:38 23 23 REMOVECH 6.0 2003/05/09 16:30:26 23 23 MERGE 2.8 2003/05/20 11:15:35 23 23 HDREDIT2 1.6 2003/05/20 11:22:58 ? ? CLEAN 4.2 2003/05/20 11:23:42 23 23 SORT 3.4.1 2004/04/13 14:06:46 23 23 MERGE 3.4 2012/07/18 14:02:00 23 23 SORT 3.5 2012/11/29 15:46:54 23 23 MERGE 3.4 2012/11/29 15:47:51 23 23 SORT 3.5 2012/11/29 15:59:00 23 23 HDREDIT2 2.5.1 2012/11/29 16:01:06 ? ? CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:07:27 23 23 $END $REMARKS -The following CHANNEL(S) were removed from file. Temperature:Sample -The following CHANNEL(S) were removed from file. Flask_Number -The following CHANNEL(S) were removed from file. Silicate Nitrate_plus_nitrite Phosphate -The following MERGE parameters were used: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Nitrate_plus_Nitrite, Phosphate, Silicate Primary file : H:\STNPCHEM\process\1995\1995-05\bottle\95050033.rem Secondary file: H:\STNPCHEM\process\1995\1995-05\bottle\95050033.rev CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel -The following MERGE parameters were used: 2012/07/18 14:02:00 2012/07/18 14:02:00 2012/07/18 14:02: Merge Channel: Pressure Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Secondary Primary Channels to Include: ALL Secondary Channels to Include: Carbon:Dissolved:Organic, Nitrogen:Dissolved:Organic Primary file : P:\John Pages Archive\1995-05\DOC&DON\1995-05-0033.che Secondary file: P:\John Pages Archive\1995-05\DOC&DON\1995-05-0033.ios -SORT parameters: 2012/11/29 15:46:54 Sorted in ascending order of channel Sample_Number -The following MERGE parameters were used: 2012/11/29 15:47:50 2012/11/29 15:47:51 2012/11/29 15:47: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Secondary Primary Channels to Include: ALL Secondary Channels to Include: Chlorofluorocarbon_11, Flag:Chlorofluorocarbon_11, Chlorofluorocarbon_12, Flag:Chlorofluorocarbon_12 Primary file : P:\John Pages Archive\1995-05\CFC\1995-05-0033.srt Secondary file: P:\John Pages Archive\1995-05\CFC\1995-05-0033.ios -SORT parameters: 2012/11/29 15:59:00 Sorted in ascending order of channel Pressure -HEADER EDITS: 2012/11/29 16:01:06 Applied edit header: O:\Data Processing\Header Comments\Work\Freons_with_flags.txt $END *INSTRUMENT TYPE : Bottle MODEL : Niskin 10 Litre *COMMENTS Collection method: ------------------ A rosette, holding 24 ten-litre water samplers, with a CTD was used. Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. Nutrient samples are analyzed fresh on board using a Technicon AAII auto- analyzer following methods described in Barwell-Clarke and Whitney (1996). Chlorophyll was extracted with 90% acetone and analyzed fluorimetrically. CFC-11 and CFC-12, in their current form, do not meet the relaxed WOCE standard for CFC's. Therefore the CFC qulaity flags have been given a value of'3'(questionable). For CFC methods refer to the "Centre for Ocean Climate Chemistry Freon Data Report" located in the cruise .DOC directory. . References: 1. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 2. J. Barwell-Clarke and F. Whitney. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. 3. Minkley, B.G., and F.A. Whitney. 2001. Summary of Hydrographic/CTD Observations Made Along Line P and at Station P: 1991-1999. Canadian Data Report of Hydrography and Ocean Sciences 156: 45 pp. !-1-- --2--- ---3--- --4-- ---5---- 6- ---7---- --8-- --9--- --10- --11-- --12-- ---13-- - ---15-- - !Samp Pressu Oxygen: Oxyge Salinity Bo Temperat Nitra Phosph Silic Carbon Nitrog Chlorof F Chlorof F !le_ re Dissolv n: :Bottle tt ure te_ ate ate : en: luoroca l luoroca l !Numb ed Disso ~u plus_ Dissol Dissol rbon_11 ~ rbon_12 ~ !er lved mb Nitri ved:Or ved:Or 1 1 ! er te ganic ganic 1 2 !---- ------ ------- ----- -------- -- -------- ----- ------ ----- ------ ------ ------- - ------- - *END OF HEADER 77 10.1 6.987 304.4 32.4774 22 8.6362 7.2 0.92 12.7 84.94 5.71 4.507 3 2.528 3 78 10.1 6.969 303.6 32.4776 23 8.6404 7.9 0.92 12.5 -99.00 -99.00 4.460 3 2.400 3 76 26.7 7.033 306.4 32.4804 21 8.0682 7.4 0.92 12.7 82.44 5.11 4.504 3 2.541 3 75 50.8 7.052 307.1 32.4966 20 7.6240 7.6 0.93 12.3 -99.00 -99.00 4.521 3 2.456 3 74 78.0 6.962 303.2 32.4903 19 6.8523 8.8 1.03 13.3 83.25 5.39 4.656 3 2.383 3 73 100.5 6.731 293.1 32.5459 18 6.7815 10.2 1.10 15.0 -99.00 -99.00 4.595 3 3.630 3 72 150.7 4.451 193.6 33.6946 17 6.3210 25.8 1.88 39.6 76.57 7.03 3.410 3 1.811 3 71 200.7 3.645 158.6 33.8358 16 5.7634 30.6 2.18 51.0 -99.00 -99.00 2.997 3 1.504 3 70 300.3 2.346 102.0 33.8736 15 4.7511 37.5 2.66 70.2 70.41 -99.00 1.977 3 1.068 3 69 400.1 1.532 66.6 33.9563 14 4.2588 41.2 2.91 87.1 -99.00 -99.00 1.206 3 0.661 3 68 603.2 0.673 29.3 34.1527 13 3.7940 44.2 3.13 113.0 -99.00 -99.00 0.345 3 0.240 3 67 802.7 0.438 19.1 34.2878 12 3.3393 45.0 3.23 131.0 -99.00 -99.00 0.000 3 0.000 3 66 1002.4 0.342 14.9 34.3703 11 2.9822 45.4 3.23 144.0 -99.00 -99.00 0.000 3 0.000 3 65 1249.4 0.371 16.1 34.4385 10 2.6681 45.6 3.23 155.0 -99.00 -99.00 -99.000 9 -99.000 9 64 1499.8 0.610 26.5 34.5036 9 2.3394 45.2 3.18 164.0 -99.00 -99.00 -99.000 9 -99.000 9 63 1748.2 0.964 41.9 34.5524 8 2.1144 44.0 3.11 169.0 -99.00 -99.00 -99.000 9 -99.000 9 62 2000.2 1.311 57.0 34.5857 7 1.9510 43.3 3.05 173.0 -99.00 -99.00 -99.000 9 -99.000 9 61 2249.7 1.552 67.4 34.6123 6 1.8205 42.5 2.98 174.0 -99.00 -99.00 -99.000 9 -99.000 9 60 2501.2 1.990 86.5 34.6319 5 1.7189 41.6 2.92 175.0 -99.00 -99.00 -99.000 9 -99.000 9 59 2751.3 2.252 97.9 34.6446 4 1.6516 40.9 2.86 175.0 -99.00 -99.00 -99.000 9 -99.000 9 58 3000.6 2.458 106.8 34.6543 3 1.6064 40.2 2.81 174.0 -99.00 -99.00 -99.000 9 -99.000 9 57 3249.9 2.605 113.2 34.6610 2 1.5860 39.8 2.78 174.0 -99.00 -99.00 -99.000 9 -99.000 9 56 3679.2 2.785 121.1 34.6704 1 1.5754 39.6 2.74 175.0 -99.00 -99.00 -99.000 9 -99.000 9