*2013/12/16 15:07:27.50 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 1995/05/13 01:17:00.000 NUMBER OF RECORDS : 23 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII NUMBER OF CHANNELS : 16 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ---------------------------- ---------------- -------------- -------------- 1 Sample_Number n/a 33 55 2 Pressure decibar 23.9 3274.5 3 Oxygen:Dissolved mL/L 0.307 6.886 4 Oxygen:Dissolved umol/kg 13.3 300 5 Salinity:Bottle PSS-78 32.4951 34.6504 6 Bottle_Number n/a 1 23 7 Temperature 'deg C (IPTS68)' 1.662 9.5615 8 Nitrate_plus_Nitrite umol/L 2.9 44.8 9 Phosphate umol/L 0.62 3.26 10 Silicate umol/L 8.1 177.4 11 Carbon:Dissolved:Organic umol/L 73.47 91.91 12 Nitrogen:Dissolved:Organic umol/L 3.18 7.36 13 Chlorofluorocarbon_11 pmol/kg 0 4.453 14 Flag:Chlorofluorocarbon_11 n/a 15 Chlorofluorocarbon_12 pmol/kg 0 3.477 16 Flag:Chlorofluorocarbon_12 n/a $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 8 F ' ' 3 4 -99 ' ' 6 F ' ' 1 5 -99 ' ' 9 F ' ' 4 6 -99 ' ' 3 I I 0 7 -99 ' ' 9 F ' ' 4 8 -99 ' ' 6 F R4 1 9 -99 ' ' 7 F R4 2 10 -99 ' ' 6 F R4 1 11 -99 ' ' ' ' F7.2 R4 ' ' 12 -99 ' ' ' ' F7.2 R4 ' ' 13 -99 ' ' ' ' F8.3 R4 ' ' 14 0 ' ' 2 NQ C ' ' 15 -99 ' ' ' ' F8.3 R4 ' ' 16 0 ' ' 2 NQ C ' ' $END $REMARKS Data quality is expressed with the following flags ------------------------------------------------------------------------------ 1 = Sample for this measurement was drawn from water bottle but not analyzed (not normally used). 2 = Acceptable measurement (not normally used). 3 = Questionable measurement (no problem observed in sampling or analysis, but value is not trusted, nonetheless; includes outlyers). 4 = Bad measurement (known problem with sampling or analysis, but not serious enough to completely discard the value). 5 = Not reported (lost sample; unredeemably bad measurement). 6 = Mean of replicate measurements. 7 = Manual chromatographic peak measurement. 8 = Irregular digital chromatographic peak integration. 9 = Sample not drawn for this measurement from this bottle (not normally used). ------------------------------------------------------------------------------ $END *ADMINISTRATION MISSION : 1995-05 AGENCY : IOS, Ocean Science and Productivity, Sidney, B.C. COUNTRY : Canada PROJECT : Line P, WOCE, JGOFS SCIENTIST : Whitney F. PLATFORM : John P. Tully *LOCATION STATION : MP12 EVENT NUMBER : 23 LATITUDE : 48 58.26000 N ! (deg min) LONGITUDE : 130 38.94000 W ! (deg min) WATER DEPTH : 3290 *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- REMOVECH 3.2 2000/02/23 16:16:40 23 23 HDREDIT2 1.2 2001/12/31 13:46:43 ? ? REMOVECH 6.0 2001/12/31 13:50:38 23 23 REMOVECH 6.0 2003/05/09 16:30:26 23 23 MERGE 2.8 2003/05/20 11:15:35 23 23 HDREDIT2 1.6 2003/05/20 11:22:58 ? ? CLEAN 4.2 2003/05/20 11:23:42 23 23 SORT 3.4.1 2004/04/13 14:06:44 23 23 MERGE 3.4 2012/07/18 14:02:00 23 23 SORT 3.5 2012/11/29 15:46:54 23 23 MERGE 3.4 2012/11/29 15:47:51 23 23 SORT 3.5 2012/11/29 15:59:00 23 23 HDREDIT2 2.5.1 2012/11/29 16:01:06 ? ? CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:07:27 23 23 $END $REMARKS -The following CHANNEL(S) were removed from file. Temperature:Sample Pressure values changed to match data checked by John Page. -The following CHANNEL(S) were removed from file. Flask_Number -The following CHANNEL(S) were removed from file. Silicate Nitrate_plus_nitrite Phosphate -The following MERGE parameters were used: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Nitrate_plus_Nitrite, Phosphate, Silicate Primary file : H:\STNPCHEM\process\1995\1995-05\bottle\95050023.rem Secondary file: H:\STNPCHEM\process\1995\1995-05\bottle\95050023.rev CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel -The following MERGE parameters were used: 2012/07/18 14:02:00 2012/07/18 14:02:00 Merge Channel: Pressure Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Secondary Primary Channels to Include: ALL Secondary Channels to Include: Carbon:Dissolved:Organic, Nitrogen:Dissolved:Organic Primary file : P:\John Pages Archive\1995-05\DOC&DON\1995-05-0023.che Secondary file: P:\John Pages Archive\1995-05\DOC&DON\1995-05-0023.ios -SORT parameters: 2012/11/29 15:46:54 Sorted in ascending order of channel Sample_Number -The following MERGE parameters were used: 2012/11/29 15:47:50 2012/11/29 15:47:51 Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Secondary Primary Channels to Include: ALL Secondary Channels to Include: Chlorofluorocarbon_11, Flag:Chlorofluorocarbon_11, Chlorofluorocarbon_12, Flag:Chlorofluorocarbon_12 Primary file : P:\John Pages Archive\1995-05\CFC\1995-05-0023.srt Secondary file: P:\John Pages Archive\1995-05\CFC\1995-05-0023.ios -SORT parameters: 2012/11/29 15:59:00 Sorted in ascending order of channel Pressure -HEADER EDITS: 2012/11/29 16:01:06 Applied edit header: O:\Data Processing\Header Comments\Work\Freons_with_flags.txt $END *INSTRUMENT TYPE : Bottle MODEL : Niskin 10 Litre *COMMENTS Collection method: ------------------ A rosette, holding 24 ten-litre water samplers, with a CTD was used. Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. Nutrient samples are analyzed fresh on board using a Technicon AAII auto- analyzer following methods described in Barwell-Clarke and Whitney (1996). Chlorophyll was extracted with 90% acetone and analyzed fluorimetrically. CFC-11 and CFC-12, in their current form, do not meet the relaxed WOCE standard for CFC's. Therefore the CFC qulaity flags have been given a value of'3'(questionable). For CFC methods refer to the "Centre for Ocean Climate Chemistry Freon Data Report" located in the cruise .DOC directory. . References: 1. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 2. J. Barwell-Clarke and F. Whitney. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. 3. Minkley, B.G., and F.A. Whitney. 2001. Summary of Hydrographic/CTD Observations Made Along Line P and at Station P: 1991-1999. Canadian Data Report of Hydrography and Ocean Sciences 156: 45 pp. !-1-- --2--- ---3--- --4-- ---5---- 6- ---7---- --8-- --9--- --10- --11-- --12-- ---13-- - ---15-- - !Samp Pressu Oxygen: Oxyge Salinity Bo Temperat Nitra Phosph Silic Carbon Nitrog Chlorof F Chlorof F !le_ re Dissolv n: :Bottle tt ure te_ ate ate : en: luoroca l luoroca l !Numb ed Disso ~u plus_ Dissol Dissol rbon_11 ~ rbon_12 ~ !er lved mb Nitri ved:Or ved:Or 1 1 ! er te ganic ganic 1 2 !---- ------ ------- ----- -------- -- -------- ----- ------ ----- ------ ------ ------- - ------- - *END OF HEADER 55 23.9 6.878 299.7 32.4951 23 9.5615 2.9 0.62 8.1 91.91 7.36 4.189 3 2.145 3 54 50.2 6.886 300.0 32.5054 22 9.2377 3.5 0.66 8.3 -99.00 -99.00 4.453 3 3.477 3 53 68.9 6.708 292.2 32.5152 21 8.3388 4.9 0.75 9.4 89.55 5.17 4.349 3 2.198 3 52 98.4 5.016 218.4 33.2075 20 7.7883 18.0 1.50 23.0 85.25 4.56 3.757 3 1.966 3 51 149.8 3.110 135.3 33.7924 19 7.3137 28.8 2.14 39.7 -99.00 -99.00 2.680 3 1.386 3 50 201.6 2.768 120.4 33.9020 18 6.6509 31.6 2.30 48.3 85.90 5.67 2.181 3 1.180 3 49 299.7 1.958 85.2 33.9627 17 5.7318 36.1 2.62 64.4 -99.00 -99.00 1.414 3 0.761 3 48 398.4 1.257 54.7 34.0158 16 5.0791 39.9 2.91 79.4 82.62 3.18 0.804 3 0.569 3 47 500.6 0.897 39.0 34.0600 15 4.2769 42.1 3.04 96.8 -99.00 -99.00 0.534 3 0.952 3 46 601.6 0.621 27.0 34.1354 14 4.1134 43.4 3.12 106.0 73.47 -99.00 0.337 3 0.360 3 45 798.7 0.355 15.4 34.2840 13 3.6789 44.2 3.23 124.8 -99.00 -99.00 0.000 3 0.000 3 44 1000.0 0.307 13.3 34.3807 12 3.3418 44.7 3.26 137.4 -99.00 -99.00 0.000 3 0.000 3 43 1250.8 0.437 19.0 34.4552 11 2.8129 44.8 3.23 153.1 -99.00 -99.00 0.000 3 0.000 3 42 1501.4 0.705 30.7 34.5085 10 2.4097 44.2 3.17 164.3 -99.00 -99.00 0.000 3 0.000 3 41 1750.1 1.069 46.5 34.5562 9 2.1265 43.6 3.08 170.7 -99.00 -99.00 0.000 3 0.000 3 39 1998.9 1.411 61.3 34.5892 7 1.9451 42.9 3.02 174.9 -99.00 -99.00 0.000 3 0.000 3 40 1998.9 1.406 61.1 34.5891 8 1.9451 42.7 3.03 174.8 -99.00 -99.00 -99.000 9 -99.000 9 38 2249.5 1.728 75.1 34.6140 6 1.8197 42.0 2.96 177.3 -99.00 -99.00 -99.000 9 -99.000 9 37 2501.6 1.927 83.7 34.6276 5 1.7483 41.7 2.92 176.9 -99.00 -99.00 -99.000 9 -99.000 9 35 2749.2 2.182 94.8 34.6419 3 1.6763 41.4 2.88 177.4 -99.00 -99.00 -99.000 9 -99.000 9 36 2749.2 2.189 95.1 34.6418 4 1.6763 41.1 2.87 177.3 -99.00 -99.00 -99.000 9 -99.000 9 34 3000.0 2.312 100.5 34.6485 2 1.6620 41.0 2.84 176.8 -99.00 -99.00 -99.000 9 -99.000 9 33 3274.5 2.348 102.1 34.6504 1 1.6702 41.0 2.83 176.1 -99.00 -99.00 -99.000 9 -99.000 9