*2013/12/16 15:06:42.60 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 1994/08/17 05:21:49.000 NUMBER OF RECORDS : 11 DATA DESCRIPTION : Bottle:Rosette:Up:Stop FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------------ --------- -------------- -------------- 1 Sample_Number n/a 1 11 2 Pressure decibar 5 130 3 Oxygen:Dissolved mL/L 2.938 6.464 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 8 F ' ' 3 $END $REMARKS Raw data in file 94310150 VI03 = 10.025 ! Volume of iodate standard (cm**3) NI03 = .0101326 ! Normalitity of iodate standard VREG = 2.0 ! Volume of sample displaced by reagents (cm**3) DOREG = 0.0017 ! Absolute amount of O2 added with reagents (ml) UFLAG = -1 ! 0|-1, -1 indicates DO_mass is valid $END *ADMINISTRATION MISSION : 1994-31 AGENCY : IOS, Ocean Physics Division, Sidney, B.C. COUNTRY : Canada PROJECT : Laperouse, JGOFS SCIENTIST : Denman K.L. PLATFORM : John P. Tully *LOCATION STATION : LD06 EVENT NUMBER : 150 LATITUDE : 48 46.10000 N ! (deg min) LONGITUDE : 126 10.18000 W ! (deg min) WATER DEPTH : 137 *INSTRUMENT TYPE : Brinkman Dosimat and PC 900 Colorimeter MODEL : 665 $REMARKS Dissolved oxygen concentration determined using an automated titration system consisting of a Brinkman Dosimat (model 665) and a PC 900 Colorimeter. $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- AutoOxy.bas 1.4 1994/08/17 07:46:07 ' ' 11 CLEAN 2.2 1997/04/22 09:12:37 11 11 REMOVECH 3.2 2000/01/10 15:58:23 11 11 REMOVECH 6.0 2003/09/16 11:21:36 11 11 HDREDIT2 1.7 2003/09/16 11:27:55 ? ? CLEAN 4.4 2003/09/16 11:30:07 11 11 SORT 3.4.1 2004/04/13 13:53:37 11 11 HDREDIT2 2.0 2004/04/30 17:39:23 ? ? CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:06:42 11 11 $END $REMARKS C.H. Culbertson's paper on Dissolved Oxygen in the 'Woce Hydrographic Program Operations and Methods - July 1991' CLEAN functions performed: - Reset #RECS, MIN & MAX values in header. -The following CHANNEL(S) were removed from file. TEMPERATURE:SAMPLE DISSOLVED_OXYGEN:MASS THIOSULFATE_TITER FLASK_NUMBER FLASK_VOLUME BLANK STANDARD SALINITY:CTD -No channels were removed. CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel $END *COMMENTS bottle #7 (25 db) leaks. salinity values from CTD with corection of .1 added. !-1-- --2--- ---3--- !Samp Pressu Oxygen: !le_ re Dissolv !Numb ed !er !---- ------ ------- *END OF HEADER 11 5.0 6.464 10 10.0 4.559 9 15.0 3.877 8 20.0 3.666 7 25.0 3.703 6 30.0 4.209 5 35.0 3.448 4 40.0 3.126 3 50.0 2.938 2 100.0 3.668 1 130.0 3.001