*2013/12/16 15:06:42.49 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 1994/08/16 10:32:31.000 NUMBER OF RECORDS : 12 DATA DESCRIPTION : Bottle:Rosette:Up:Stop FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 4 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------------ --------- -------------- -------------- 1 Sample_Number n/a 134 145 2 Pressure decibar 1 950 3 Salinity:Bottle PSS-78 31.536 34.335 4 Oxygen:Dissolved mL/L 0.25 6.243 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 8 F ' ' 3 4 -99 ' ' 8 F ' ' 3 $END $REMARKS Raw data in file 94310130 VI03 = 10.025 ! Volume of iodate standard (cm**3) NI03 = .0101326 ! Normalitity of iodate standard VREG = 2.0 ! Volume of sample displaced by reagents (cm**3) DOREG = 0.0017 ! Absolute amount of O2 added with reagents (ml) UFLAG = -1 ! 0|-1, -1 indicates DO_mass is valid $END *ADMINISTRATION MISSION : 1994-31 AGENCY : IOS, Ocean Physics Division, Sidney, B.C. COUNTRY : Canada PROJECT : Laperouse, JGOFS SCIENTIST : Denman K.L. PLATFORM : John P. Tully *LOCATION STATION : LG06 EVENT NUMBER : 130 LATITUDE : 49 2.94000 N ! (deg min) LONGITUDE : 127 0.81000 W ! (deg min) WATER DEPTH : 973 *INSTRUMENT TYPE : Brinkman Dosimat and PC 900 Colorimeter MODEL : 665 $REMARKS Dissolved oxygen concentration determined using an automated titration system consisting of a Brinkman Dosimat (model 665) and a PC 900 Colorimeter. $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- AutoOxy.bas 1.4 1994/08/16 09:12:55 ' ' 12 CLEAN 2.2 1997/04/22 09:12:35 12 12 REMOVECH 3.2 2000/01/10 15:58:21 12 12 REMOVECH 6.0 2003/09/16 11:21:36 12 12 HDREDIT2 1.7 2003/09/16 11:27:55 ? ? CLEAN 4.4 2003/09/16 11:30:07 12 12 SORT 3.4.1 2004/04/13 13:53:27 12 12 HDREDIT2 2.0 2004/04/30 17:39:16 ? ? CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:06:42 12 12 $END $REMARKS C.H. Culbertson's paper on Dissolved Oxygen in the 'Woce Hydrographic Program Operations and Methods - July 1991' CLEAN functions performed: - Reset #RECS, MIN & MAX values in header. -The following CHANNEL(S) were removed from file. TEMPERATURE:SAMPLE DISSOLVED_OXYGEN:MASS THIOSULFATE_TITER FLASK_NUMBER FLASK_VOLUME BLANK STANDARD SALINITY:CTD -The following CHANNEL(S) were removed from file. Temperature:CTD CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel $END *COMMENTS oxygen at 1.0 db has to be recalculated using correct salinity. 800 db sample had stirrer bar added with acid, flask volume will be reduced. !-1-- --2--- ---3--- ---4--- !Samp Pressu Salinit Oxygen: !le_ re y: Dissolv !Numb Bottle ed !er !---- ------ ------- ------- *END OF HEADER 134 1.0 31.536 6.091 135 10.0 31.612 6.243 136 20.0 31.805 6.062 137 30.0 31.984 4.829 138 50.0 32.419 5.703 139 75.0 32.932 4.872 140 100.0 33.299 4.126 141 200.0 33.885 2.947 142 500.0 34.079 0.833 143 800.0 34.259 0.276 144 850.0 34.293 0.290 145 950.0 34.335 0.250