*2013/12/16 15:06:42.47 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 1994/08/16 07:15:00.000 NUMBER OF RECORDS : 10 DATA DESCRIPTION : Bottle:Rosette:Up:Stop FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 4 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------------ --------- -------------- -------------- 1 Sample_Number n/a 1 10 2 Pressure decibar 1 135 3 Salinity:Bottle PSS-78 31.823 33.883 4 Oxygen:Dissolved mL/L 2.018 6.86 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 8 F ' ' 3 4 -99 ' ' 8 F ' ' 3 $END $REMARKS Raw data in file 94310124 VI03 = 10.025 ! Volume of iodate standard (cm**3) NI03 = .0101326 ! Normalitity of iodate standard VREG = 2.0 ! Volume of sample displaced by reagents (cm**3) DOREG = 0.0017 ! Absolute amount of O2 added with reagents (ml) UFLAG = -1 ! 0|-1, -1 indicates DO_mass is valid $END *ADMINISTRATION MISSION : 1994-31 AGENCY : IOS, Ocean Physics Division, Sidney, B.C. COUNTRY : Canada PROJECT : Laperouse, JGOFS SCIENTIST : Denman K.L. PLATFORM : John P. Tully *LOCATION STATION : LG04 EVENT NUMBER : 124 LATITUDE : 49 11.26000 N ! (deg min) LONGITUDE : 126 48.96000 W ! (deg min) WATER DEPTH : 142 *INSTRUMENT TYPE : Brinkman Dosimat and PC 900 Colorimeter MODEL : 665 $REMARKS Dissolved oxygen concentration determined using an automated titration system consisting of a Brinkman Dosimat (model 665) and a PC 900 Colorimeter. $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- AutoOxy.bas 1.4 1994/08/16 13:00:49 ' ' 10 CLEAN 2.2 1997/04/22 09:12:35 10 10 REMOVECH 3.2 2000/01/10 15:58:21 10 10 REMOVECH 6.0 2003/09/16 11:21:36 10 10 HDREDIT2 1.7 2003/09/16 11:27:55 ? ? CLEAN 4.4 2003/09/16 11:30:07 10 10 SORT 3.4.1 2004/04/13 13:53:25 10 10 HDREDIT2 2.0 2004/04/30 17:39:15 ? ? CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 15:06:42 10 10 $END $REMARKS C.H. Culbertson's paper on Dissolved Oxygen in the 'Woce Hydrographic Program Operations and Methods - July 1991' CLEAN functions performed: - Reset #RECS, MIN & MAX values in header. -The following CHANNEL(S) were removed from file. TEMPERATURE:SAMPLE DISSOLVED_OXYGEN:MASS THIOSULFATE_TITER FLASK_NUMBER FLASK_VOLUME BLANK STANDARD SALINITY:CTD -No channels were removed. CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel $END !-1-- --2--- ---3--- ---4--- !Samp Pressu Salinit Oxygen: !le_ re y: Dissolv !Numb Bottle ed !er !---- ------ ------- ------- *END OF HEADER 10 1.0 31.823 6.397 9 10.0 32.290 6.860 8 20.0 32.677 4.702 7 30.0 32.905 3.808 6 50.0 33.280 3.286 5 75.0 33.676 2.797 4 100.0 33.849 2.918 1 135.0 33.883 2.057 2 135.0 33.883 2.018 3 135.0 33.883 2.021