*2013/12/16 14:42:58.81 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : UTC 1994/05/11 09:40:06.000 NUMBER OF RECORDS : 10 DATA DESCRIPTION : Bottle:Rosette:Up:Stop + CTD:Up FILE TYPE : ASCII NUMBER OF CHANNELS : 10 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------------ ---------------- -------------- -------------- 1 Sample_Number n/a 105 114 2 Pressure decibar 0.5 105.5 3 Oxygen:Dissolved mL/L 4.758 5.59 4 Oxygen:Dissolved umol/kg 207.5 243.9 5 Salinity:Bottle PSS-78 30.554 31.335 6 Temperature 'deg C (IPTS68)' 8.735 9.26 7 Nitrate umol/L 20.4 24 8 Nitrite umol/L 0.23 0.27 9 Phosphate umol/L 1.81 2.05 10 Silicate umol/L 35.2 38.9 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 5 I I 0 2 -99 ' ' 7 F ' ' 1 3 -99 ' ' 8 F ' ' 3 4 -99 ' ' 6 F ' ' 1 5 -99 ' ' 9 F ' ' 4 6 -99 ' ' 9 F ' ' 4 7 -99 ' ' 6 F R4 1 8 -99 ' ' ' ' F7.2 R4 ' ' 9 -99 ' ' 7 F R4 2 10 -99 ' ' 6 F R4 1 $END $REMARKS Raw data in file 94020009 VI03 = 10.043 ! Volume of iodate standard (cm**3) NI03 = .010131 ! Normalitity of iodate standard VREG = 2.0 ! Volume of sample displaced by reagents (cm**3) DOREG = 0.0017 ! Absolute amount of O2 added with reagents (ml) UFLAG = -1 ! 0|-1, -1 indicates DO_mass is valid $END *ADMINISTRATION MISSION : 1994-02 AGENCY : 'IOS, Climate Chemistry and Ocean Physics, Sidney,' CONTINUED : ' B.C.' COUNTRY : Canada PROJECT : Line P, WOCE, JGOFS SCIENTIST : Whitney F. PLATFORM : John P. Tully *LOCATION STATION : SH12 EVENT NUMBER : 9 LATITUDE : 48 26.80000 N ! (deg min) LONGITUDE : 123 9.41000 W ! (deg min) WATER DEPTH : 110 *INSTRUMENT TYPE : Bottle MODEL : Niskin 10 Litre $REMARKS Dissolved oxygen concentration determined using an automated titration system consisting of a Brinkman Dosimat (model 665) and a PC 900 Colorimeter. $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- AutoOxy.bas 1.2 1994/05/11 07:54:09 ' ' 10 CLEAN 2.1 1994/05/21 16:41:46 10 10 MERGE 2.3 1999/01/27 14:25:37 10 10 REMOVECH 6.0 2003/05/20 15:44:13 10 10 MERGE 2.8 2003/05/20 15:45:04 10 10 HDREDIT2 1.6 2003/05/20 15:52:47 ? ? CLEAN 4.2 2003/05/20 15:55:50 10 10 SORT 3.4.1 2004/04/23 11:15:03 10 10 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 14:42:58 10 10 $END $REMARKS C.H. Culbertson's paper on Dissolved Oxygen in the 'Woce Hydrographic Program Operations and Methods - July 1991' -The following CLEAN parameters were used. -The following MERGE parameters were used: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: pressure, Dissolved_Oxygen:vol, Dissolved_Oxygen:mas, Flask_Number, Salinity:Bottle Secondary Channels to Include: Temperature:CTD, Silicate, Nitrate, Phosphate Primary file : e:\data\1994\9402\94020009.hyd Secondary file: e:\data\1994\9402\94020009.ios -The following CHANNEL(S) were removed from file. Flask_Number Silicate Nitrate_plus_nitrite Phosphate -The following MERGE parameters were used: Merge Channel: Sample_Number Merge Scheme Used: Add Secondary to Primary Overlap Scheme Used: Keep Primary Primary Channels to Include: ALL Secondary Channels to Include: Nitrate, Nitrite, Phosphate, Silicate Primary file : H:\STNPCHEM\process\1994\1994-02\bottle\94020009.rem Secondary file: H:\STNPCHEM\process\1994\1994-02\bottle\94020009.ios CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. -The following SORT parameters were used. Sorted by channel: Pressure Pressure channel sorted according to values in sort channel $END *COMMENTS Collection method: ------------------ A rosette, holding 24 ten-litre water samplers, with a CTD was used. Analysis methods: ----------------- Salinity samples are collected in glass bottles and analyzed on Guildline model 8410 Portasal Salinometers which are standardized with IAPSO standard seawater. Oxygen samples are analyzed on an automated Winkler titration system following the procedures of Carpenter (1965). A Brinkmann model 665 Dosimat and model PC910 Colorimeter is controlled by Visual-Basic program to titrate the oxygen samples. Nutrient samples are analyzed fresh on board using a Technicon AAII auto- analyzer following methods described in Barwell-Clarke and Whitney (1996). Chlorophyll was extracted with 90% acetone and analyzed fluorimetrically. References: 1. Carpenter, J.H. 1965. The Chesapeake Bay Institute Technique for the Winkler Dissolved Oxygen Method. Limmnol. & Oceanogr., 10: 141-143. 2. J. Barwell-Clarke and F. Whitney. 1996. Institute of Ocean Sciences Nutrient Methods and Analysis. Canadian Technical Report of Hydrography and Ocean Sciences, No. 182, 43 pp. 3. Minkley, B.G., and F.A. Whitney. 2001. Summary of Hydrographic/CTD Observations Made Along Line P and at Station P: 1991-1999. Canadian Data Report of Hydrography and Ocean Sciences 156: 45 pp. !-1-- --2--- ---3--- --4-- ---5---- ---6---- --7-- --8--- --9--- --10- !Samp Pressu Oxygen: Oxyge Salinity Temperat Nitra Nitrit Phosph Silic !le_ re Dissolv n: :Bottle ure te e ate ate !Numb ed Disso !er lved !---- ------ ------- ----- -------- -------- ----- ------ ------ ----- *END OF HEADER 105 0.5 5.590 243.9 30.5540 9.2600 20.4 0.26 1.87 35.2 106 10.1 5.404 235.8 30.7450 9.2600 21.3 0.26 1.81 36.3 107 10.2 5.420 236.5 30.7370 9.2420 21.4 0.27 1.83 35.9 108 19.8 5.207 227.1 30.9080 9.0760 22.0 0.25 1.88 36.3 109 29.9 5.163 225.2 30.9320 9.0780 22.3 0.25 1.89 37.1 110 49.7 5.157 224.9 30.9820 9.0250 22.3 0.24 2.00 37.9 111 76.0 4.974 216.9 31.1420 8.9390 23.0 0.23 2.00 38.0 112 100.8 4.805 209.5 31.3350 8.7350 23.7 0.24 2.05 38.9 113 100.8 4.758 207.5 31.3220 8.7790 24.0 0.24 2.01 38.7 114 105.5 4.930 215.0 31.2240 8.8300 23.2 0.25 2.02 38.0