*2003/07/28 11:47:56.23 *IOS HEADER VERSION 1.4 2002/12/04 2002/12/04 *FILE START TIME : UTC 1990/08/26 17:20:00.000 NUMBER OF RECORDS : 56 DATA DESCRIPTION : CTD FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum ! -- ------------- ---------------- -------------- -------------- 1 Depth metres 0 55 2 Temperature 'deg C (IPTS68)' 12.704 15.574 3 Salinity PSS-78 31.615 31.979 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places ! -- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 6 F ' ' 0 2 -99 ' ' 8 F ' ' 3 3 -99 ' ' 8 F ' ' 3 $END $REMARKS This file converted from 12 line header format. $END *ADMINISTRATION MISSION : 1990-30 AGENCY : IOS, Tides & Currents, Sidney, B.C. COUNTRY : Canada PROJECT : PERD, Charolettes SCIENTIST : Crawford W.R. PLATFORM : Westerly Wind *LOCATION GEOGRAPHIC AREA : DIXON ENTRANCE, HECATE STRAIT STATION : 182 EVENT NUMBER : 182 LATITUDE : 52 53.40000 N ! (deg min) LONGITUDE : 131 56.10000 W ! (deg min) *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-19 SERIAL NUMBER : 193390-451 $TABLE: SENSORS ! Name Abs Depth Serial No ! -------------- -------------- ---------- Pressure n/a ? Temperature n/a ? Conductivity n/a ? $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! -------- ------ ---------- -------- --------- --------- C12L_IOS 2.0 1993/08/21 11:13:43 56 56 HDREDIT2 1.6 2003/07/28 11:36:19 ? ? CLEAN 4.3.1 2003/07/28 11:47:56 56 56 $END $REMARKS CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. $END *COMMENTS Profile made by Seakem Oceanography: R. Kashino, P. Greisman, S. Gormikan on MV Westerly Wind while tracking near-surface drifters. A Seabird water pump was attached to the conductivity cell. See Inst. Ocean Sciences library report IOSPB -CR-199 for initial processing by Seakem. Final editing by IOS scientists J. Linguanti & W. Crawford: conductivity lagged by 0.6 sec., and obvious spikes in the data removed. Initial data sampled at 2/sec, 0.75 to 1.0 m/s drop speed. SBE-19 CTD SN 193390-451 with submersible pump for flushing the conductivity cell . Sea-Bird Electronics, Inc. CTD acquisition software, SEASOFT VERSION 3.3. !--1-- ---2--- ---3--- !Depth Tempera Salinit ! ture y !----- ------- ------- *END OF HEADER 0. 15.574 31.627 1. 15.568 31.625 2. 15.537 31.615 3. 15.317 31.638 4. 14.935 31.691 5. 14.553 31.738 6. 14.396 31.778 7. 14.319 31.796 8. 14.250 31.797 9. 14.100 31.793 10. 13.977 31.821 11. 13.894 31.832 12. 13.829 31.843 13. 13.763 31.847 14. 13.705 31.852 15. 13.660 31.854 16. 13.593 31.860 17. 13.565 31.869 18. 13.552 31.874 19. 13.521 31.875 20. 13.457 31.878 21. 13.436 31.892 22. 13.389 31.895 23. 13.351 31.902 24. 13.330 31.906 25. 13.322 31.907 26. 13.313 31.908 27. 13.294 31.910 28. 13.279 31.912 29. 13.228 31.909 30. 13.169 31.925 31. 13.142 31.930 32. 13.108 31.934 33. 13.076 31.940 34. 13.036 31.945 35. 13.009 31.951 36. 12.984 31.953 37. 12.967 31.957 38. 12.963 31.958 39. 12.951 31.958 40. 12.921 31.957 41. 12.896 31.962 42. 12.892 31.963 43. 12.883 31.960 44. 12.868 31.959 45. 12.856 31.960 46. 12.851 31.961 47. 12.846 31.961 48. 12.825 31.964 49. 12.820 31.966 50. 12.812 31.968 51. 12.804 31.970 52. 12.777 31.974 53. 12.750 31.973 54. 12.714 31.979 55. 12.704 31.977