*2003/07/28 11:47:53.87 *IOS HEADER VERSION 1.4 2002/12/04 2002/12/04 *FILE START TIME : UTC 1990/08/17 08:50:00.000 NUMBER OF RECORDS : 12 DATA DESCRIPTION : CTD FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum ! -- ------------- ---------------- -------------- -------------- 1 Depth metres 0 11 2 Temperature 'deg C (IPTS68)' 12.914 13.307 3 Salinity PSS-78 31.939 31.975 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places ! -- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 6 F ' ' 0 2 -99 ' ' 8 F ' ' 3 3 -99 ' ' 8 F ' ' 3 $END $REMARKS This file converted from 12 line header format. $END *ADMINISTRATION MISSION : 1990-30 AGENCY : IOS, Tides & Currents, Sidney, B.C. COUNTRY : Canada PROJECT : PERD, Charolettes SCIENTIST : Crawford W.R. PLATFORM : Westerly Wind *LOCATION GEOGRAPHIC AREA : DIXON ENTRANCE, HECATE STRAIT STATION : 142 EVENT NUMBER : 142 LATITUDE : 52 34.20000 N ! (deg min) LONGITUDE : 131 26.40000 W ! (deg min) *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-19 SERIAL NUMBER : 193390-451 $TABLE: SENSORS ! Name Abs Depth Serial No ! -------------- -------------- ---------- Pressure n/a ? Temperature n/a ? Conductivity n/a ? $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! -------- ------ ---------- -------- --------- --------- C12L_IOS 2.0 1993/08/21 11:13:02 12 12 HDREDIT2 1.6 2003/07/28 11:36:17 ? ? CLEAN 4.3.1 2003/07/28 11:47:53 12 12 $END $REMARKS CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. $END *COMMENTS Profile made by Seakem Oceanography: R. Kashino, P. Greisman, S. Gormikan on MV Westerly Wind while tracking near-surface drifters. A Seabird water pump was attached to the conductivity cell. See Inst. Ocean Sciences library report IOSPB -CR-199 for initial processing by Seakem. Final editing by IOS scientists J. Linguanti & W. Crawford: conductivity lagged by 0.6 sec., and obvious spikes in the data removed. Initial data sampled at 2/sec, 0.75 to 1.0 m/s drop speed. SBE-19 CTD SN 193390-451 with submersible pump for flushing the conductivity cell . Sea-Bird Electronics, Inc. CTD acquisition software, SEASOFT VERSION 3.3. !--1-- ---2--- ---3--- !Depth Tempera Salinit ! ture y !----- ------- ------- *END OF HEADER 0. 13.307 31.947 1. 13.283 31.946 2. 13.185 31.943 3. 13.162 31.949 4. 13.162 31.947 5. 13.161 31.946 6. 13.133 31.939 7. 13.005 31.952 8. 12.938 31.968 9. 12.922 31.969 10. 12.914 31.975 11. 12.927 31.971