*2003/07/28 11:47:53.46 *IOS HEADER VERSION 1.4 2002/12/04 2002/12/04 *FILE START TIME : UTC 1990/08/13 18:07:00.000 NUMBER OF RECORDS : 46 DATA DESCRIPTION : CTD FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum ! -- ------------- ---------------- -------------- -------------- 1 Depth metres 0 45 2 Temperature 'deg C (IPTS68)' 16.918 17.404 3 Salinity PSS-78 31.544 31.591 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places ! -- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 6 F ' ' 0 2 -99 ' ' 8 F ' ' 3 3 -99 ' ' 8 F ' ' 3 $END $REMARKS This file converted from 12 line header format. $END *ADMINISTRATION MISSION : 1990-30 AGENCY : IOS, Tides & Currents, Sidney, B.C. COUNTRY : Canada PROJECT : PERD, Charolettes SCIENTIST : Crawford W.R. PLATFORM : Westerly Wind *LOCATION GEOGRAPHIC AREA : DIXON ENTRANCE, HECATE STRAIT STATION : 134 EVENT NUMBER : 134 LATITUDE : 53 15.20000 N ! (deg min) LONGITUDE : 131 55.50000 W ! (deg min) *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-19 SERIAL NUMBER : 193390-451 $TABLE: SENSORS ! Name Abs Depth Serial No ! -------------- -------------- ---------- Pressure n/a ? Temperature n/a ? Conductivity n/a ? $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! -------- ------ ---------- -------- --------- --------- C12L_IOS 2.0 1993/08/21 11:12:55 46 46 HDREDIT2 1.6 2003/07/28 11:36:17 ? ? CLEAN 4.3.1 2003/07/28 11:47:53 46 46 $END $REMARKS CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. $END *COMMENTS Profile made by Seakem Oceanography: R. Kashino, P. Greisman, S. Gormikan on MV Westerly Wind while tracking near-surface drifters. A Seabird water pump was attached to the conductivity cell. See Inst. Ocean Sciences library report IOSPB -CR-199 for initial processing by Seakem. Final editing by IOS scientists J. Linguanti & W. Crawford: conductivity lagged by 0.6 sec., and obvious spikes in the data removed. Initial data sampled at 2/sec, 0.75 to 1.0 m/s drop speed. SBE-19 CTD SN 193390-451 with submersible pump for flushing the conductivity cell . Sea-Bird Electronics, Inc. CTD acquisition software, SEASOFT VERSION 3.3. !--1-- ---2--- ---3--- !Depth Tempera Salinit ! ture y !----- ------- ------- *END OF HEADER 0. 17.392 31.584 1. 17.404 31.580 2. 17.403 31.587 3. 17.403 31.585 4. 17.395 31.586 5. 17.377 31.582 6. 17.366 31.582 7. 17.326 31.582 8. 17.297 31.591 9. 17.290 31.585 10. 17.265 31.579 11. 17.264 31.569 12. 17.259 31.582 13. 17.209 31.571 14. 17.171 31.575 15. 17.128 31.570 16. 17.045 31.548 17. 16.957 31.544 18. 16.928 31.549 19. 16.922 31.555 20. 16.925 31.557 21. 16.927 31.558 22. 16.928 31.559 23. 16.931 31.557 24. 16.932 31.559 25. 16.932 31.558 26. 16.929 31.556 27. 16.925 31.553 28. 16.920 31.553 29. 16.918 31.555 30. 16.920 31.559 31. 16.923 31.558 32. 16.926 31.560 33. 16.930 31.563 34. 16.931 31.560 35. 16.930 31.561 36. 16.930 31.560 37. 16.935 31.564 38. 16.944 31.566 39. 16.947 31.566 40. 16.947 31.567 41. 16.945 31.567 42. 16.945 31.571 43. 16.947 31.571 44. 16.947 31.575 45. 16.948 31.578