*2003/07/28 11:47:47.73 *IOS HEADER VERSION 1.4 2002/12/04 2002/12/04 *FILE START TIME : UTC 1990/07/15 09:55:00.000 NUMBER OF RECORDS : 26 DATA DESCRIPTION : CTD FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum ! -- ------------- ---------------- -------------- -------------- 1 Depth metres 0 25 2 Temperature 'deg C (IPTS68)' 11.858 14.932 3 Salinity PSS-78 31.833 32.097 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places ! -- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 6 F ' ' 0 2 -99 ' ' 8 F ' ' 3 3 -99 ' ' 8 F ' ' 3 $END $REMARKS This file converted from 12 line header format. $END *ADMINISTRATION MISSION : 1990-30 AGENCY : IOS, Tides & Currents, Sidney, B.C. COUNTRY : Canada PROJECT : PERD, Charolettes SCIENTIST : Crawford W.R. PLATFORM : Westerly Wind *LOCATION GEOGRAPHIC AREA : DIXON ENTRANCE, HECATE STRAIT STATION : 51 EVENT NUMBER : 51 LATITUDE : 52 23.38000 N ! (deg min) LONGITUDE : 129 54.31000 W ! (deg min) *INSTRUMENT TYPE : Sea-Bird CTD MODEL : SBE-19 SERIAL NUMBER : 193390-451 $TABLE: SENSORS ! Name Abs Depth Serial No ! -------------- -------------- ---------- Pressure n/a ? Temperature n/a ? Conductivity n/a ? $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! -------- ------ ---------- -------- --------- --------- C12L_IOS 2.0 1993/08/21 11:11:44 26 26 HDREDIT2 1.6 2003/07/28 11:36:12 ? ? CLEAN 4.3.1 2003/07/28 11:47:47 26 26 $END $REMARKS CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. $END *COMMENTS Profile made by Seakem Oceanography: R. Kashino, P. Greisman, S. Gormikan on MV Westerly Wind while tracking near-surface drifters. A Seabird water pump was attached to the conductivity cell. See Inst. Ocean Sciences library report IOSPB -CR-199 for initial processing by Seakem. Final editing by IOS scientists J. Linguanti & W. Crawford: conductivity lagged by 0.6 sec., and obvious spikes in the data removed. Initial data sampled at 2/sec, 0.75 to 1.0 m/s drop speed. SBE-19 CTD SN 193390-451 with submersible pump for flushing the conductivity cell . Sea-Bird Electronics, Inc. CTD acquisition software, SEASOFT VERSION 3.3. !--1-- ---2--- ---3--- !Depth Tempera Salinit ! ture y !----- ------- ------- *END OF HEADER 0. 14.928 31.835 1. 14.928 31.833 2. 14.931 31.836 3. 14.932 31.836 4. 14.931 31.836 5. 14.930 31.836 6. 14.929 31.836 7. 14.928 31.837 8. 14.928 31.838 9. 14.927 31.842 10. 14.917 31.855 11. 14.900 31.871 12. 14.841 31.871 13. 14.637 31.877 14. 14.077 31.918 15. 13.703 31.973 16. 13.606 31.984 17. 13.440 32.039 18. 13.129 32.072 19. 13.025 32.076 20. 12.925 32.084 21. 12.789 32.083 22. 12.612 32.097 23. 12.341 32.048 24. 12.034 32.072 25. 11.858 32.035