*2013/12/16 14:16:18.34 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : PST 1978/03/23 09:25:00.000 NUMBER OF RECORDS : 44 DATA DESCRIPTION : CTD FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------- ---------------- -------------- -------------- 1 Pressure decibar 3.3 205.2 2 Temperature 'deg C (IPTS68)' 8.017 8.226 3 Salinity ppt 28.953 31.527 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 7 F ' ' 1 2 -99 ' ' 8 F ' ' 3 3 -99 ' ' 8 F ' ' 3 $END $REMARKS This file converted from 12 line header format. $END *ADMINISTRATION MISSION : 1978-12 AGENCY : IOS, Offshore Oceanography, Sidney, B.C. COUNTRY : Canada PROJECT : Georgia Strait,L.S.C SCIENTIST : Thomson R.E. PLATFORM : Parizeau *LOCATION GEOGRAPHIC AREA : Georgia, Juan De Fuca, Haro STATION : H 5 EVENT NUMBER : 185 LATITUDE : 48 46.40000 N ! (deg min) LONGITUDE : 123 1.50000 W ! (deg min) *INSTRUMENT TYPE : Guildline Analog CTD MODEL : 8701 $TABLE: SENSORS ! Name Abs Depth Serial No ! -------------- -------------- ---------- Pressure n/a ? Temperature n/a ? Conductivity n/a ? $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- HP_IOS 1.0 1993/11/09 13:21:24 46 46 DELETE 4.4 2000/01/25 13:57:58 46 44 HDREDIT2 1.6 2003/06/13 11:45:09 ? ? CLEAN 4.2 2003/06/13 11:45:36 44 44 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 14:16:18 44 44 $END $REMARKS -The following DELETE parameters were used: Surface Record Removal: Last Press Min Maximum Surface Pressure (relative): 20.00 Surface Swell Pressure Tolerance: 1.00 Pressure NOT filtered Swells deleted. Warning message if pressure difference of 100.00 Slow Drop Rate NOT deleted CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. $END *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ------------- --------------- ---- ------ ------------ Temperature 'DEG C (ITS68)' 11 ' ' (Pressure) (-0.154E-01 0.5325E-04) Salinity ppt 11 ' ' (Pressure) (-0.268E-01 -0.4894E-04) $END *COMMENTS PROCESSED CTD DATA FROM THE HP 2100 ACQUISITION SYSTEM, CONVERTED FROM BINARY TO ASCII. HYDRO CORRECTIONS HAVE BEEN APPLIED TO THE DATA. Collection method: Salinity-Temperature-pressure data were obtained with a Guildline CTD. Output from the probe consisted of analogue voltages of temperature, conductivity and pressure. The probe output was input into a 2100-series HP computer, digitized at a rate of 10 samples per second and stored on a 9-track magnetic tape. !--1--- ---2--- ---3--- !Pressu Tempera Salinit !re ture y !------ ------- ------- *END OF HEADER 3.3 8.069 28.962 3.5 8.071 28.959 4.1 8.072 28.976 5.2 8.076 28.953 10.2 8.047 29.165 15.1 8.041 29.268 20.1 8.030 29.508 25.0 8.022 29.903 30.2 8.021 29.851 35.2 8.017 30.015 40.0 8.032 30.101 45.1 8.040 30.179 50.2 8.046 30.253 55.0 8.050 30.336 60.1 8.049 30.328 65.2 8.053 30.326 70.1 8.063 30.426 75.3 8.094 30.623 80.0 8.103 30.654 85.3 8.107 30.694 90.0 8.114 30.725 95.1 8.120 30.767 100.2 8.134 30.834 105.1 8.138 30.855 110.1 8.141 30.866 115.3 8.143 30.863 120.0 8.148 30.883 125.1 8.150 30.921 130.0 8.152 30.916 135.0 8.156 30.931 140.4 8.157 30.937 145.0 8.161 30.985 150.1 8.173 31.059 155.1 8.176 31.106 160.0 8.179 31.142 165.2 8.181 31.121 170.0 8.182 31.161 175.1 8.196 31.322 180.3 8.218 31.501 185.0 8.223 31.522 190.1 8.220 31.527 195.0 8.224 31.527 200.2 8.225 31.518 205.2 8.226 31.513