*2013/12/16 14:16:18.12 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : PST 1978/03/23 05:08:00.000 NUMBER OF RECORDS : 46 DATA DESCRIPTION : CTD FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------- ---------------- -------------- -------------- 1 Pressure decibar 0.3 190.1 2 Temperature 'deg C (IPTS68)' 7.855 8.384 3 Salinity ppt 27.096 30.885 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 7 F ' ' 1 2 -99 ' ' 8 F ' ' 3 3 -99 ' ' 8 F ' ' 3 $END $REMARKS This file converted from 12 line header format. $END *ADMINISTRATION MISSION : 1978-12 AGENCY : IOS, Offshore Oceanography, Sidney, B.C. COUNTRY : Canada PROJECT : Georgia Strait,L.S.C SCIENTIST : Thomson R.E. PLATFORM : Parizeau *LOCATION GEOGRAPHIC AREA : Georgia, Juan De Fuca, Haro STATION : BP10 EVENT NUMBER : 174 LATITUDE : 48 50.80000 N ! (deg min) LONGITUDE : 123 4.80000 W ! (deg min) *INSTRUMENT TYPE : Guildline Analog CTD MODEL : 8701 $TABLE: SENSORS ! Name Abs Depth Serial No ! -------------- -------------- ---------- Pressure n/a ? Temperature n/a ? Conductivity n/a ? $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- HP_IOS 1.0 1993/11/09 13:19:30 131 131 DELETE 4.4 2000/01/25 13:57:49 131 46 HDREDIT2 1.6 2003/06/13 11:45:09 ? ? CLEAN 4.2 2003/06/13 11:45:36 46 46 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 14:16:18 46 46 $END $REMARKS -The following DELETE parameters were used: Surface Record Removal: Last Press Min Maximum Surface Pressure (relative): 20.00 Surface Swell Pressure Tolerance: 1.00 Pressure NOT filtered Swells deleted. Warning message if pressure difference of 100.00 Slow Drop Rate NOT deleted CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. $END *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ------------- --------------- ---- ------ ------------ Temperature 'DEG C (ITS68)' 11 ' ' (Pressure) (-0.154E-01 0.5325E-04) Salinity ppt 11 ' ' (Pressure) (-0.268E-01 -0.4894E-04) $END *COMMENTS PROCESSED CTD DATA FROM THE HP 2100 ACQUISITION SYSTEM, CONVERTED FROM BINARY TO ASCII. HYDRO CORRECTIONS HAVE BEEN APPLIED TO THE DATA. Collection method: Salinity-Temperature-pressure data were obtained with a Guildline CTD. Output from the probe consisted of analogue voltages of temperature, conductivity and pressure. The probe output was input into a 2100-series HP computer, digitized at a rate of 10 samples per second and stored on a 9-track magnetic tape. !--1--- ---2--- ---3--- !Pressu Tempera Salinit !re ture y !------ ------- ------- *END OF HEADER 0.3 8.187 27.548 0.4 8.193 27.582 0.6 8.191 27.580 0.8 8.193 27.570 1.1 8.232 27.525 2.0 8.384 27.096 3.4 8.210 27.487 4.0 8.319 27.166 5.2 8.359 27.139 10.1 7.855 28.814 15.2 8.019 29.426 20.1 8.037 29.502 25.0 8.038 29.509 30.2 8.038 29.523 35.3 8.058 29.577 40.3 8.052 29.672 45.1 8.050 29.683 50.1 8.046 29.742 55.0 8.030 29.820 60.1 8.031 29.844 65.1 8.036 29.869 70.0 8.036 29.881 75.1 8.059 29.949 80.1 8.077 30.110 85.2 8.082 30.158 90.2 8.086 30.201 95.0 8.088 30.256 100.1 8.092 30.258 105.0 8.093 30.258 110.1 8.095 30.319 115.1 8.104 30.366 120.0 8.112 30.423 125.1 8.116 30.496 130.2 8.120 30.504 135.0 8.120 30.539 140.2 8.123 30.552 145.1 8.132 30.610 150.2 8.154 30.787 155.0 8.156 30.825 160.2 8.157 30.845 165.1 8.157 30.835 170.0 8.159 30.840 175.1 8.162 30.841 180.2 8.162 30.845 185.0 8.165 30.863 190.1 8.167 30.885