*2013/12/16 14:16:18.11 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : PST 1978/03/23 04:39:00.000 NUMBER OF RECORDS : 47 DATA DESCRIPTION : CTD FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------- ---------------- -------------- -------------- 1 Pressure decibar 0.1 190.1 2 Temperature 'deg C (IPTS68)' 8.014 8.344 3 Salinity ppt 27.719 30.706 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 7 F ' ' 1 2 -99 ' ' 8 F ' ' 3 3 -99 ' ' 8 F ' ' 3 $END $REMARKS This file converted from 12 line header format. $END *ADMINISTRATION MISSION : 1978-12 AGENCY : IOS, Offshore Oceanography, Sidney, B.C. COUNTRY : Canada PROJECT : Georgia Strait,L.S.C SCIENTIST : Thomson R.E. PLATFORM : Parizeau *LOCATION GEOGRAPHIC AREA : Georgia, Juan De Fuca, Haro STATION : BP 9 EVENT NUMBER : 173 LATITUDE : 48 50.30000 N ! (deg min) LONGITUDE : 123 2.40000 W ! (deg min) *INSTRUMENT TYPE : Guildline Analog CTD MODEL : 8701 $TABLE: SENSORS ! Name Abs Depth Serial No ! -------------- -------------- ---------- Pressure n/a ? Temperature n/a ? Conductivity n/a ? $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- HP_IOS 1.0 1993/11/09 13:19:12 118 118 DELETE 4.4 2000/01/25 13:57:48 118 47 HDREDIT2 1.6 2003/06/13 11:45:09 ? ? CLEAN 4.2 2003/06/13 11:45:36 47 47 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 14:16:18 47 47 $END $REMARKS -The following DELETE parameters were used: Surface Record Removal: Last Press Min Maximum Surface Pressure (relative): 20.00 Surface Swell Pressure Tolerance: 1.00 Pressure NOT filtered Swells deleted. Warning message if pressure difference of 100.00 Slow Drop Rate NOT deleted CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. $END *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ------------- --------------- ---- ------ ------------ Temperature 'DEG C (ITS68)' 11 ' ' (Pressure) (-0.154E-01 0.5325E-04) Salinity ppt 11 ' ' (Pressure) (-0.268E-01 -0.4894E-04) $END *COMMENTS PROCESSED CTD DATA FROM THE HP 2100 ACQUISITION SYSTEM, CONVERTED FROM BINARY TO ASCII. HYDRO CORRECTIONS HAVE BEEN APPLIED TO THE DATA. Collection method: Salinity-Temperature-pressure data were obtained with a Guildline CTD. Output from the probe consisted of analogue voltages of temperature, conductivity and pressure. The probe output was input into a 2100-series HP computer, digitized at a rate of 10 samples per second and stored on a 9-track magnetic tape. !--1--- ---2--- ---3--- !Pressu Tempera Salinit !re ture y !------ ------- ------- *END OF HEADER 0.1 8.331 27.865 0.3 8.333 27.859 0.5 8.332 27.853 0.6 8.329 27.864 0.8 8.333 27.858 1.1 8.328 27.854 2.1 8.329 27.857 3.0 8.338 27.784 4.0 8.344 27.719 5.3 8.338 27.722 10.2 8.304 28.048 15.0 8.303 28.117 20.1 8.117 29.171 25.0 8.014 29.733 30.0 8.025 29.837 35.1 8.027 29.849 40.2 8.031 29.866 45.1 8.034 29.880 50.1 8.035 29.876 55.1 8.038 29.889 60.1 8.044 29.906 65.1 8.043 29.908 70.1 8.045 29.919 75.1 8.046 29.915 80.0 8.054 29.966 85.2 8.059 29.984 90.2 8.062 30.027 95.1 8.072 30.043 100.2 8.073 30.040 105.0 8.075 30.052 110.1 8.095 30.133 115.1 8.095 30.181 120.2 8.101 30.265 125.2 8.110 30.298 130.0 8.113 30.355 135.3 8.118 30.424 140.1 8.122 30.487 145.1 8.122 30.471 150.1 8.121 30.497 155.0 8.123 30.494 160.1 8.122 30.502 165.1 8.126 30.501 170.2 8.128 30.529 175.1 8.135 30.559 180.0 8.137 30.593 185.0 8.143 30.625 190.1 8.148 30.706