*2013/12/16 14:16:18.04 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : PST 1978/03/23 03:24:00.000 NUMBER OF RECORDS : 48 DATA DESCRIPTION : CTD FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------- ---------------- -------------- -------------- 1 Pressure decibar 0 190.1 2 Temperature 'deg C (IPTS68)' 8.07 8.139 3 Salinity ppt 29.492 30.597 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 7 F ' ' 1 2 -99 ' ' 8 F ' ' 3 3 -99 ' ' 8 F ' ' 3 $END $REMARKS This file converted from 12 line header format. $END *ADMINISTRATION MISSION : 1978-12 AGENCY : IOS, Offshore Oceanography, Sidney, B.C. COUNTRY : Canada PROJECT : Georgia Strait,L.S.C SCIENTIST : Thomson R.E. PLATFORM : Parizeau *LOCATION GEOGRAPHIC AREA : Georgia, Juan De Fuca, Haro STATION : BP 7 EVENT NUMBER : 170 LATITUDE : 48 48.50000 N ! (deg min) LONGITUDE : 122 55.30000 W ! (deg min) *INSTRUMENT TYPE : Guildline Analog CTD MODEL : 8701 $TABLE: SENSORS ! Name Abs Depth Serial No ! -------------- -------------- ---------- Pressure n/a ? Temperature n/a ? Conductivity n/a ? $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- HP_IOS 1.0 1993/11/09 13:18:44 83 83 DELETE 4.4 2000/01/25 13:57:47 83 48 HDREDIT2 1.6 2003/06/13 11:45:09 ? ? CLEAN 4.2 2003/06/13 11:45:36 48 48 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 14:16:18 48 48 $END $REMARKS -The following DELETE parameters were used: Surface Record Removal: Last Press Min Maximum Surface Pressure (relative): 20.00 Surface Swell Pressure Tolerance: 1.00 Pressure NOT filtered Swells deleted. Warning message if pressure difference of 100.00 Slow Drop Rate NOT deleted CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. $END *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ------------- --------------- ---- ------ ------------ Temperature 'DEG C (ITS68)' 11 ' ' (Pressure) (-0.154E-01 0.5325E-04) Salinity ppt 11 ' ' (Pressure) (-0.268E-01 -0.4894E-04) $END *COMMENTS PROCESSED CTD DATA FROM THE HP 2100 ACQUISITION SYSTEM, CONVERTED FROM BINARY TO ASCII. HYDRO CORRECTIONS HAVE BEEN APPLIED TO THE DATA. Collection method: Salinity-Temperature-pressure data were obtained with a Guildline CTD. Output from the probe consisted of analogue voltages of temperature, conductivity and pressure. The probe output was input into a 2100-series HP computer, digitized at a rate of 10 samples per second and stored on a 9-track magnetic tape. !--1--- ---2--- ---3--- !Pressu Tempera Salinit !re ture y !------ ------- ------- *END OF HEADER 0.0 8.101 29.526 0.1 8.100 29.523 0.4 8.101 29.522 0.6 8.102 29.522 0.7 8.101 29.521 0.8 8.101 29.525 1.1 8.100 29.526 2.2 8.099 29.535 3.1 8.101 29.522 4.0 8.101 29.501 5.0 8.103 29.492 10.1 8.106 29.525 15.0 8.092 29.627 20.1 8.098 29.621 25.1 8.094 29.637 30.0 8.086 29.647 35.1 8.081 29.656 40.0 8.087 29.648 45.1 8.091 29.655 50.2 8.095 29.637 55.1 8.100 29.633 60.1 8.082 29.652 65.1 8.084 29.650 70.1 8.075 29.660 75.1 8.070 29.728 80.1 8.070 29.720 85.1 8.070 29.727 90.0 8.072 29.726 95.1 8.072 29.757 100.3 8.076 29.778 105.1 8.085 29.842 110.2 8.081 29.938 115.3 8.088 30.115 120.0 8.099 30.220 125.1 8.103 30.231 130.0 8.103 30.257 135.0 8.108 30.324 140.1 8.115 30.323 145.0 8.117 30.328 150.1 8.121 30.346 155.1 8.120 30.391 160.0 8.119 30.426 165.1 8.124 30.507 170.0 8.127 30.501 175.1 8.134 30.563 180.1 8.135 30.595 185.0 8.138 30.597 190.1 8.139 30.592