*2013/12/16 14:16:17.94 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : PST 1978/03/23 01:10:00.000 NUMBER OF RECORDS : 55 DATA DESCRIPTION : CTD FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------- ---------------- -------------- -------------- 1 Pressure decibar 0 217.6 2 Temperature 'deg C (IPTS68)' 7.993 8.143 3 Salinity ppt 28.013 30.643 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 7 F ' ' 1 2 -99 ' ' 8 F ' ' 3 3 -99 ' ' 8 F ' ' 3 $END $REMARKS This file converted from 12 line header format. $END *ADMINISTRATION MISSION : 1978-12 AGENCY : IOS, Offshore Oceanography, Sidney, B.C. COUNTRY : Canada PROJECT : Georgia Strait,L.S.C SCIENTIST : Thomson R.E. PLATFORM : Parizeau *LOCATION GEOGRAPHIC AREA : Georgia, Juan De Fuca, Haro STATION : BP 2 EVENT NUMBER : 164 LATITUDE : 48 49.80000 N ! (deg min) LONGITUDE : 123 0.00000 W ! (deg min) *INSTRUMENT TYPE : Guildline Analog CTD MODEL : 8701 $TABLE: SENSORS ! Name Abs Depth Serial No ! -------------- -------------- ---------- Pressure n/a ? Temperature n/a ? Conductivity n/a ? $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- HP_IOS 1.0 1993/11/09 13:18:14 107 107 DELETE 4.4 2000/01/25 13:57:42 107 55 HDREDIT2 1.6 2003/06/13 11:45:08 ? ? CLEAN 4.2 2003/06/13 11:45:35 55 55 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 14:16:17 55 55 $END $REMARKS -The following DELETE parameters were used: Surface Record Removal: Last Press Min Maximum Surface Pressure (relative): 20.00 Surface Swell Pressure Tolerance: 1.00 Pressure NOT filtered Swells deleted. Warning message if pressure difference of 100.00 Slow Drop Rate NOT deleted CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. $END *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ------------- --------------- ---- ------ ------------ Temperature 'DEG C (ITS68)' 11 ' ' (Pressure) (-0.154E-01 0.5325E-04) Salinity ppt 11 ' ' (Pressure) (-0.268E-01 -0.4894E-04) $END *COMMENTS PROCESSED CTD DATA FROM THE HP 2100 ACQUISITION SYSTEM, CONVERTED FROM BINARY TO ASCII. HYDRO CORRECTIONS HAVE BEEN APPLIED TO THE DATA. Collection method: Salinity-Temperature-pressure data were obtained with a Guildline CTD. Output from the probe consisted of analogue voltages of temperature, conductivity and pressure. The probe output was input into a 2100-series HP computer, digitized at a rate of 10 samples per second and stored on a 9-track magnetic tape. !--1--- ---2--- ---3--- !Pressu Tempera Salinit !re ture y !------ ------- ------- *END OF HEADER 0.0 8.071 28.394 0.4 8.071 28.380 0.5 8.077 28.157 0.6 8.079 28.338 0.7 8.085 28.380 0.8 8.089 28.373 0.9 8.086 28.352 1.2 8.086 28.353 2.1 8.095 28.330 3.4 8.104 28.138 4.2 8.143 28.013 5.1 8.134 28.086 10.4 8.063 29.324 15.0 8.074 29.349 20.2 8.075 29.374 25.1 8.067 29.426 30.1 8.048 29.536 35.3 7.993 29.621 40.2 7.993 29.691 45.1 8.005 29.948 50.3 8.015 29.975 55.1 8.017 29.970 60.2 8.019 29.994 65.0 8.029 30.062 70.1 8.054 30.146 75.2 8.048 30.162 80.0 8.053 30.175 85.3 8.053 30.162 90.0 8.056 30.164 95.0 8.077 30.185 100.2 8.076 30.177 105.0 8.077 30.195 110.1 8.073 30.174 115.1 8.069 30.175 120.2 8.061 30.124 125.2 8.089 30.190 130.1 8.068 30.141 135.1 8.092 30.209 140.1 8.094 30.195 145.0 8.094 30.213 150.2 8.107 30.363 155.1 8.111 30.354 160.0 8.116 30.371 165.2 8.115 30.397 170.1 8.114 30.368 175.2 8.118 30.378 180.1 8.118 30.431 185.1 8.119 30.440 190.1 8.127 30.516 195.0 8.127 30.518 200.1 8.140 30.615 205.1 8.138 30.608 210.0 8.142 30.638 215.1 8.141 30.631 217.6 8.143 30.643