*2013/12/16 14:16:17.67 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : PST 1978/03/22 19:54:00.000 NUMBER OF RECORDS : 51 DATA DESCRIPTION : CTD FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------- ---------------- -------------- -------------- 1 Pressure decibar 0 200.1 2 Temperature 'deg C (IPTS68)' 7.957 8.305 3 Salinity ppt 27.347 30.746 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 7 F ' ' 1 2 -99 ' ' 8 F ' ' 3 3 -99 ' ' 8 F ' ' 3 $END $REMARKS This file converted from 12 line header format. $END *ADMINISTRATION MISSION : 1978-12 AGENCY : IOS, Offshore Oceanography, Sidney, B.C. COUNTRY : Canada PROJECT : Georgia Strait,L.S.C SCIENTIST : Thomson R.E. PLATFORM : Parizeau *LOCATION GEOGRAPHIC AREA : Georgia, Juan De Fuca, Haro STATION : BP10 EVENT NUMBER : 149 LATITUDE : 48 50.80000 N ! (deg min) LONGITUDE : 123 4.80000 W ! (deg min) *INSTRUMENT TYPE : Guildline Analog CTD MODEL : 8701 $TABLE: SENSORS ! Name Abs Depth Serial No ! -------------- -------------- ---------- Pressure n/a ? Temperature n/a ? Conductivity n/a ? $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- HP_IOS 1.0 1993/11/09 13:17:53 92 92 DELETE 4.4 2000/01/25 13:57:33 92 51 HDREDIT2 1.6 2003/06/13 11:45:08 ? ? CLEAN 4.2 2003/06/13 11:45:35 51 51 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 14:16:17 51 51 $END $REMARKS -The following DELETE parameters were used: Surface Record Removal: Last Press Min Maximum Surface Pressure (relative): 20.00 Surface Swell Pressure Tolerance: 1.00 Pressure NOT filtered Swells deleted. Warning message if pressure difference of 100.00 Slow Drop Rate NOT deleted CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. $END *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ------------- --------------- ---- ------ ------------ Temperature 'DEG C (ITS68)' 11 ' ' (Pressure) (-0.154E-01 0.5325E-04) Salinity ppt 11 ' ' (Pressure) (-0.268E-01 -0.4894E-04) $END *COMMENTS PROCESSED CTD DATA FROM THE HP 2100 ACQUISITION SYSTEM, CONVERTED FROM BINARY TO ASCII. HYDRO CORRECTIONS HAVE BEEN APPLIED TO THE DATA. Collection method: Salinity-Temperature-pressure data were obtained with a Guildline CTD. Output from the probe consisted of analogue voltages of temperature, conductivity and pressure. The probe output was input into a 2100-series HP computer, digitized at a rate of 10 samples per second and stored on a 9-track magnetic tape. !--1--- ---2--- ---3--- !Pressu Tempera Salinit !re ture y !------ ------- ------- *END OF HEADER 0.0 8.305 27.347 0.3 8.298 27.383 0.5 8.298 27.414 0.6 8.295 27.455 0.7 8.292 27.473 0.8 8.283 27.457 0.9 8.263 27.491 1.1 8.256 27.569 2.0 8.234 27.602 3.3 8.155 27.954 4.0 8.062 28.252 5.0 7.973 28.329 10.2 7.966 28.456 15.0 7.957 28.877 20.1 8.019 29.518 25.2 8.027 29.542 30.0 8.017 29.636 35.2 8.013 29.627 40.1 7.996 29.632 45.1 7.973 29.689 50.1 7.968 29.697 55.1 7.967 29.732 60.2 7.966 29.727 65.0 7.967 29.737 70.1 7.972 29.849 75.1 8.012 29.960 80.1 8.022 29.966 85.2 8.037 29.986 90.1 8.042 30.013 95.0 8.061 30.124 100.1 8.065 30.140 105.2 8.069 30.168 110.1 8.070 30.191 115.1 8.072 30.190 120.0 8.078 30.236 125.3 8.080 30.245 130.0 8.106 30.321 135.2 8.114 30.372 140.3 8.120 30.388 145.0 8.120 30.405 150.1 8.121 30.452 155.0 8.122 30.502 160.0 8.129 30.515 165.1 8.127 30.508 170.0 8.126 30.520 175.1 8.127 30.554 180.1 8.134 30.588 185.1 8.137 30.612 190.1 8.142 30.651 195.0 8.144 30.677 200.1 8.151 30.746