*2013/12/16 14:16:17.65 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : PST 1978/03/22 19:28:00.000 NUMBER OF RECORDS : 46 DATA DESCRIPTION : CTD FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------- ---------------- -------------- -------------- 1 Pressure decibar 0.5 190.3 2 Temperature 'deg C (IPTS68)' 7.937 8.295 3 Salinity ppt 27.704 30.719 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 7 F ' ' 1 2 -99 ' ' 8 F ' ' 3 3 -99 ' ' 8 F ' ' 3 $END $REMARKS This file converted from 12 line header format. $END *ADMINISTRATION MISSION : 1978-12 AGENCY : IOS, Offshore Oceanography, Sidney, B.C. COUNTRY : Canada PROJECT : Georgia Strait,L.S.C SCIENTIST : Thomson R.E. PLATFORM : Parizeau *LOCATION GEOGRAPHIC AREA : Georgia, Juan De Fuca, Haro STATION : BP 9 EVENT NUMBER : 148 LATITUDE : 48 50.30000 N ! (deg min) LONGITUDE : 123 2.40000 W ! (deg min) *INSTRUMENT TYPE : Guildline Analog CTD MODEL : 8701 $TABLE: SENSORS ! Name Abs Depth Serial No ! -------------- -------------- ---------- Pressure n/a ? Temperature n/a ? Conductivity n/a ? $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- HP_IOS 1.0 1993/11/09 13:17:51 81 81 DELETE 4.4 2000/01/25 13:57:33 81 46 HDREDIT2 1.6 2003/06/13 11:45:08 ? ? CLEAN 4.2 2003/06/13 11:45:35 46 46 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 14:16:17 46 46 $END $REMARKS -The following DELETE parameters were used: Surface Record Removal: Last Press Min Maximum Surface Pressure (relative): 20.00 Surface Swell Pressure Tolerance: 1.00 Pressure NOT filtered Swells deleted. Warning message if pressure difference of 100.00 Slow Drop Rate NOT deleted CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. $END *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ------------- --------------- ---- ------ ------------ Temperature 'DEG C (ITS68)' 11 ' ' (Pressure) (-0.154E-01 0.5325E-04) Salinity ppt 11 ' ' (Pressure) (-0.268E-01 -0.4894E-04) $END *COMMENTS PROCESSED CTD DATA FROM THE HP 2100 ACQUISITION SYSTEM, CONVERTED FROM BINARY TO ASCII. HYDRO CORRECTIONS HAVE BEEN APPLIED TO THE DATA. Collection method: Salinity-Temperature-pressure data were obtained with a Guildline CTD. Output from the probe consisted of analogue voltages of temperature, conductivity and pressure. The probe output was input into a 2100-series HP computer, digitized at a rate of 10 samples per second and stored on a 9-track magnetic tape. !--1--- ---2--- ---3--- !Pressu Tempera Salinit !re ture y !------ ------- ------- *END OF HEADER 0.5 8.288 27.704 0.6 8.295 27.789 0.7 8.252 28.052 0.9 8.220 27.767 1.1 8.212 27.867 2.0 8.179 28.295 3.1 8.154 28.269 4.1 8.137 28.413 5.1 8.118 28.581 10.1 8.071 28.824 15.0 8.062 28.859 20.2 8.058 29.225 25.0 8.027 29.420 30.2 8.007 29.457 35.3 7.983 29.552 40.0 7.960 29.650 45.1 7.953 29.707 50.1 7.941 29.758 55.0 7.942 29.786 60.1 7.937 29.811 65.0 7.949 29.855 70.4 7.983 29.924 75.3 8.012 29.972 80.0 8.026 30.019 85.1 8.045 30.067 90.0 8.055 30.085 95.0 8.066 30.120 100.1 8.078 30.162 105.2 8.080 30.160 110.1 8.081 30.256 115.1 8.091 30.337 120.1 8.104 30.420 125.2 8.106 30.427 130.2 8.108 30.435 135.1 8.111 30.440 140.1 8.113 30.465 145.0 8.117 30.463 150.2 8.119 30.471 155.1 8.124 30.508 160.0 8.125 30.533 165.2 8.128 30.530 170.0 8.131 30.559 175.1 8.136 30.609 180.0 8.137 30.604 185.1 8.141 30.641 190.3 8.147 30.719