*2013/12/16 14:16:17.56 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : PST 1978/03/22 17:23:00.000 NUMBER OF RECORDS : 55 DATA DESCRIPTION : CTD FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------- ---------------- -------------- -------------- 1 Pressure decibar 0 215.2 2 Temperature 'deg C (IPTS68)' 8.02 8.75 3 Salinity ppt 24.978 31.15 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 7 F ' ' 1 2 -99 ' ' 8 F ' ' 3 3 -99 ' ' 8 F ' ' 3 $END $REMARKS This file converted from 12 line header format. $END *ADMINISTRATION MISSION : 1978-12 AGENCY : IOS, Offshore Oceanography, Sidney, B.C. COUNTRY : Canada PROJECT : Georgia Strait,L.S.C SCIENTIST : Thomson R.E. PLATFORM : Parizeau *LOCATION GEOGRAPHIC AREA : Georgia, Juan De Fuca, Haro STATION : BP 2 EVENT NUMBER : 143 LATITUDE : 48 49.80000 N ! (deg min) LONGITUDE : 123 0.00000 W ! (deg min) *INSTRUMENT TYPE : Guildline Analog CTD MODEL : 8701 $TABLE: SENSORS ! Name Abs Depth Serial No ! -------------- -------------- ---------- Pressure n/a ? Temperature n/a ? Conductivity n/a ? $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- HP_IOS 1.0 1993/11/09 13:17:45 159 159 DELETE 4.4 2000/01/25 13:57:29 159 55 HDREDIT2 1.6 2003/06/13 11:45:08 ? ? CLEAN 4.2 2003/06/13 11:45:34 55 55 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 14:16:17 55 55 $END $REMARKS -The following DELETE parameters were used: Surface Record Removal: Last Press Min Maximum Surface Pressure (relative): 20.00 Surface Swell Pressure Tolerance: 1.00 Pressure NOT filtered Swells deleted. Warning message if pressure difference of 100.00 Slow Drop Rate NOT deleted CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. $END *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ------------- --------------- ---- ------ ------------ Temperature 'DEG C (ITS68)' 11 ' ' (Pressure) (-0.154E-01 0.5325E-04) Salinity ppt 11 ' ' (Pressure) (-0.268E-01 -0.4894E-04) $END *COMMENTS PROCESSED CTD DATA FROM THE HP 2100 ACQUISITION SYSTEM, CONVERTED FROM BINARY TO ASCII. HYDRO CORRECTIONS HAVE BEEN APPLIED TO THE DATA. Collection method: Salinity-Temperature-pressure data were obtained with a Guildline CTD. Output from the probe consisted of analogue voltages of temperature, conductivity and pressure. The probe output was input into a 2100-series HP computer, digitized at a rate of 10 samples per second and stored on a 9-track magnetic tape. !--1--- ---2--- ---3--- !Pressu Tempera Salinit !re ture y !------ ------- ------- *END OF HEADER 0.0 8.747 24.996 0.2 8.746 24.993 0.3 8.748 24.984 0.5 8.748 24.978 0.6 8.750 24.981 0.6 8.707 25.015 0.7 8.681 25.320 0.8 8.670 25.455 1.1 8.613 25.644 2.1 8.575 25.741 3.0 8.510 26.281 4.2 8.487 26.405 5.0 8.522 26.591 10.2 8.451 27.865 15.0 8.373 28.157 20.2 8.319 28.289 25.3 8.213 28.495 30.0 8.199 28.584 35.2 8.183 28.793 40.0 8.163 28.877 45.1 8.150 29.060 50.2 8.116 29.359 55.2 8.036 29.553 60.1 8.040 29.586 65.0 8.041 29.628 70.0 8.023 29.713 75.2 8.021 29.718 80.0 8.020 29.776 85.2 8.024 29.830 90.2 8.039 29.887 95.1 8.063 29.975 100.3 8.094 30.195 105.0 8.096 30.246 110.1 8.092 30.256 115.2 8.090 30.238 120.0 8.114 30.439 125.3 8.109 30.376 130.0 8.120 30.446 135.0 8.120 30.455 140.1 8.121 30.464 145.0 8.123 30.474 150.2 8.125 30.489 155.3 8.128 30.530 160.0 8.130 30.600 165.1 8.138 30.635 170.0 8.141 30.717 175.1 8.147 30.757 180.0 8.153 30.828 185.1 8.165 30.897 190.2 8.181 31.092 195.0 8.191 31.125 200.1 8.191 31.143 205.2 8.193 31.139 210.1 8.192 31.145 215.2 8.193 31.150