*2013/12/16 14:16:17.53 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : PST 1978/03/22 16:42:00.000 NUMBER OF RECORDS : 50 DATA DESCRIPTION : CTD FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------- ---------------- -------------- -------------- 1 Pressure decibar 0 210.1 2 Temperature 'deg C (IPTS68)' 7.958 8.223 3 Salinity ppt 27.431 30.697 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 7 F ' ' 1 2 -99 ' ' 8 F ' ' 3 3 -99 ' ' 8 F ' ' 3 $END $REMARKS This file converted from 12 line header format. $END *ADMINISTRATION MISSION : 1978-12 AGENCY : IOS, Offshore Oceanography, Sidney, B.C. COUNTRY : Canada PROJECT : Georgia Strait,L.S.C SCIENTIST : Thomson R.E. PLATFORM : Parizeau *LOCATION GEOGRAPHIC AREA : Georgia, Juan De Fuca, Haro STATION : BP10 EVENT NUMBER : 141 LATITUDE : 48 50.80000 N ! (deg min) LONGITUDE : 123 4.80000 W ! (deg min) *INSTRUMENT TYPE : Guildline Analog CTD MODEL : 8701 $TABLE: SENSORS ! Name Abs Depth Serial No ! -------------- -------------- ---------- Pressure n/a ? Temperature n/a ? Conductivity n/a ? $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- HP_IOS 1.0 1993/11/09 13:17:42 87 87 DELETE 4.4 2000/01/25 13:57:27 87 50 HDREDIT2 1.6 2003/06/13 11:45:08 ? ? CLEAN 4.2 2003/06/13 11:45:34 50 50 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 14:16:17 50 50 $END $REMARKS -The following DELETE parameters were used: Surface Record Removal: Last Press Min Maximum Surface Pressure (relative): 20.00 Surface Swell Pressure Tolerance: 1.00 Pressure NOT filtered Swells deleted. Warning message if pressure difference of 100.00 Slow Drop Rate NOT deleted CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. $END *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ------------- --------------- ---- ------ ------------ Temperature 'DEG C (ITS68)' 11 ' ' (Pressure) (-0.154E-01 0.5325E-04) Salinity ppt 11 ' ' (Pressure) (-0.268E-01 -0.4894E-04) $END *COMMENTS PROCESSED CTD DATA FROM THE HP 2100 ACQUISITION SYSTEM, CONVERTED FROM BINARY TO ASCII. HYDRO CORRECTIONS HAVE BEEN APPLIED TO THE DATA. Collection method: Salinity-Temperature-pressure data were obtained with a Guildline CTD. Output from the probe consisted of analogue voltages of temperature, conductivity and pressure. The probe output was input into a 2100-series HP computer, digitized at a rate of 10 samples per second and stored on a 9-track magnetic tape. !--1--- ---2--- ---3--- !Pressu Tempera Salinit !re ture y !------ ------- ------- *END OF HEADER 0.0 8.223 27.519 0.2 8.216 27.519 0.6 8.213 27.525 0.9 8.201 27.552 1.1 8.200 27.546 2.0 8.206 27.431 3.0 8.185 27.706 4.0 8.178 27.651 5.1 8.117 28.358 10.2 8.081 29.092 15.0 8.066 29.330 20.1 8.055 29.477 25.1 8.054 29.481 30.0 8.054 29.494 35.2 8.028 29.558 40.0 7.984 29.688 45.1 7.958 29.738 50.1 7.965 29.807 55.4 7.975 29.874 60.2 7.997 29.930 65.0 8.000 29.930 70.0 8.000 29.940 75.4 8.010 29.944 80.0 8.036 30.008 85.1 8.047 30.021 90.0 8.057 30.038 95.0 8.059 30.103 100.3 8.065 30.159 105.0 8.069 30.166 110.1 8.069 30.181 115.2 8.083 30.283 120.3 8.088 30.320 125.1 8.115 30.380 130.1 8.117 30.434 135.0 8.122 30.494 140.2 8.122 30.540 145.3 8.127 30.580 150.1 8.129 30.598 155.0 8.135 30.616 160.0 8.134 30.621 165.3 8.135 30.626 170.0 8.136 30.614 175.2 8.137 30.631 180.4 8.140 30.636 185.0 8.139 30.622 190.1 8.138 30.655 195.0 8.142 30.648 200.1 8.146 30.666 205.1 8.152 30.689 210.1 8.153 30.697