*2013/12/16 14:16:17.23 *IOS HEADER VERSION 1.10 2011/10/26 2011/10/26 *FILE START TIME : PST 1978/03/22 10:56:00.000 NUMBER OF RECORDS : 42 DATA DESCRIPTION : CTD FILE TYPE : ASCII DATA TYPE : REAL*4 NUMBER OF CHANNELS : 3 $TABLE: CHANNELS ! No Name Units Minimum Maximum !--- ------------- ---------------- -------------- -------------- 1 Pressure decibar 4.1 198.2 2 Temperature 'deg C (IPTS68)' 8 8.238 3 Salinity ppt 28.502 30.949 $END $TABLE: CHANNEL DETAIL ! No Pad Start Width Format Type Decimal_Places !--- ---- ----- ----- ------ ---- -------------- 1 -99 ' ' 7 F ' ' 1 2 -99 ' ' 8 F ' ' 3 3 -99 ' ' 8 F ' ' 3 $END $REMARKS This file converted from 12 line header format. $END *ADMINISTRATION MISSION : 1978-12 AGENCY : IOS, Offshore Oceanography, Sidney, B.C. COUNTRY : Canada PROJECT : Georgia Strait,L.S.C SCIENTIST : Thomson R.E. PLATFORM : Parizeau *LOCATION GEOGRAPHIC AREA : Georgia, Juan De Fuca, Haro STATION : BP 9 EVENT NUMBER : 127 LATITUDE : 48 50.30000 N ! (deg min) LONGITUDE : 123 2.40000 W ! (deg min) *INSTRUMENT TYPE : Guildline Analog CTD MODEL : 8701 $TABLE: SENSORS ! Name Abs Depth Serial No ! -------------- -------------- ---------- Pressure n/a ? Temperature n/a ? Conductivity n/a ? $END *HISTORY $TABLE: PROGRAMS ! Name Vers Date Time Recs In Recs Out ! ------------------------ ------ ---------- -------- --------- --------- HP_IOS 1.0 1993/11/09 13:17:16 44 44 DELETE 4.4 2000/01/25 13:57:19 44 42 HDREDIT2 1.6 2003/06/13 11:45:07 ? ? CLEAN 4.2 2003/06/13 11:45:34 42 42 CHANGE_CTD_CHANNEL_NAMES 1.0 2013/12/16 14:16:17 42 42 $END $REMARKS -The following DELETE parameters were used: Surface Record Removal: Last Press Min Maximum Surface Pressure (relative): 20.00 Surface Swell Pressure Tolerance: 1.00 Pressure NOT filtered Swells deleted. Warning message if pressure difference of 100.00 Slow Drop Rate NOT deleted CLEAN functions: - Reset #RECS, MIN & MAX values in header. - Change Pad Value to -99 in All Channels. - Delete Empty Channels: 0 deleted. - Set channel name post-colon letters to upper case. $END *CALIBRATION $TABLE: CORRECTED CHANNELS ! Name Units Fmla Pad Coefficients ! ------------- --------------- ---- ------ ------------ Temperature 'DEG C (ITS68)' 11 ' ' (Pressure) (-0.154E-01 0.5325E-04) Salinity ppt 11 ' ' (Pressure) (-0.268E-01 -0.4894E-04) $END *COMMENTS PROCESSED CTD DATA FROM THE HP 2100 ACQUISITION SYSTEM, CONVERTED FROM BINARY TO ASCII. HYDRO CORRECTIONS HAVE BEEN APPLIED TO THE DATA. Collection method: Salinity-Temperature-pressure data were obtained with a Guildline CTD. Output from the probe consisted of analogue voltages of temperature, conductivity and pressure. The probe output was input into a 2100-series HP computer, digitized at a rate of 10 samples per second and stored on a 9-track magnetic tape. !--1--- ---2--- ---3--- !Pressu Tempera Salinit !re ture y !------ ------- ------- *END OF HEADER 4.1 8.236 28.504 4.6 8.236 28.502 5.0 8.238 28.505 10.2 8.207 28.702 15.0 8.102 29.288 20.1 8.096 29.287 25.0 8.085 29.347 30.1 8.093 29.311 35.2 8.085 29.455 40.2 8.052 29.512 45.1 8.052 29.519 50.2 8.022 29.626 55.0 8.037 29.706 60.1 8.002 29.730 65.0 8.008 29.817 70.2 8.000 29.846 75.3 8.006 29.839 80.0 8.002 29.850 85.2 8.015 29.921 90.1 8.031 29.937 95.0 8.060 30.028 100.2 8.080 30.080 105.0 8.080 30.072 110.1 8.085 30.100 115.1 8.090 30.193 120.1 8.098 30.377 125.1 8.102 30.395 130.2 8.104 30.508 135.4 8.123 30.607 140.4 8.126 30.625 145.0 8.131 30.636 150.2 8.132 30.653 155.1 8.135 30.686 160.1 8.140 30.691 165.3 8.144 30.690 170.0 8.144 30.734 175.2 8.148 30.731 180.0 8.155 30.780 185.3 8.161 30.866 190.3 8.173 30.949 195.0 8.176 30.938 198.2 8.178 30.926